The mystery of defining aortic valve area

what have we learnt from three-dimensional imaging modalities?

Ebraham Alskaf, A. Kardos

Research output: Article

1 Citation (Scopus)

Abstract

Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.

Original languageEnglish
Pages (from-to)1-9
Number of pages9
JournalJournal of Echocardiography
DOIs
Publication statusAccepted/In press - febr. 23 2018

Fingerprint

Three-Dimensional Imaging
Aortic Valve
Aortic Valve Stenosis
Blood Volume
Cost-Benefit Analysis
Echocardiography
Research Design
Hemodynamics
Radiation
Research

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

@article{8140b197fb4f45b6baa560eb12f8cb32,
title = "The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?",
abstract = "Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.",
keywords = "Aortic valve area, Cardiac computed tomography angiography, Continuity equation, Correction factor, Echocardiography, Left ventricular outflow tract",
author = "Ebraham Alskaf and A. Kardos",
year = "2018",
month = "2",
day = "23",
doi = "10.1007/s12574-018-0374-8",
language = "English",
pages = "1--9",
journal = "Journal of Echocardiography",
issn = "1349-0222",
publisher = "Springer Japan",

}

TY - JOUR

T1 - The mystery of defining aortic valve area

T2 - what have we learnt from three-dimensional imaging modalities?

AU - Alskaf, Ebraham

AU - Kardos, A.

PY - 2018/2/23

Y1 - 2018/2/23

N2 - Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.

AB - Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.

KW - Aortic valve area

KW - Cardiac computed tomography angiography

KW - Continuity equation

KW - Correction factor

KW - Echocardiography

KW - Left ventricular outflow tract

UR - http://www.scopus.com/inward/record.url?scp=85045135672&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85045135672&partnerID=8YFLogxK

U2 - 10.1007/s12574-018-0374-8

DO - 10.1007/s12574-018-0374-8

M3 - Article

SP - 1

EP - 9

JO - Journal of Echocardiography

JF - Journal of Echocardiography

SN - 1349-0222

ER -