Response to the Commentary of Marcel Drüschler and Bernhard Roling on 'The interface between Au(1 1 1) and an ionic liquid'

Research output: Article

5 Citations (Scopus)

Abstract

The metal/ionic liquid electrode impedance is practically resistive at the high frequency range of the usual electrochemical impedance spectroscopy measurements; the deviations are artefacts most probably due to the measurement system. Therefore the use of the interfacial capacitance representation of impedance spectra is further on suggested.

Original languageEnglish
Pages (from-to)7246-7247
Number of pages2
JournalElectrochimica Acta
Volume56
Issue number20
DOIs
Publication statusPublished - aug. 1 2011

Fingerprint

Ionic Liquids
Ionic liquids
Electrochemical impedance spectroscopy
Capacitance
Metals
Electrodes

ASJC Scopus subject areas

  • Electrochemistry
  • Chemical Engineering(all)

Cite this

@article{0fff780866604ef690d67427e7b80e4b,
title = "Response to the Commentary of Marcel Dr{\"u}schler and Bernhard Roling on 'The interface between Au(1 1 1) and an ionic liquid'",
abstract = "The metal/ionic liquid electrode impedance is practically resistive at the high frequency range of the usual electrochemical impedance spectroscopy measurements; the deviations are artefacts most probably due to the measurement system. Therefore the use of the interfacial capacitance representation of impedance spectra is further on suggested.",
keywords = "Capacitance, Double layer, Electrochemical impedance spectroscopy, Equivalent circuit, Ionic liquid",
author = "T. Pajkossy",
year = "2011",
month = "8",
day = "1",
doi = "10.1016/j.electacta.2011.05.100",
language = "English",
volume = "56",
pages = "7246--7247",
journal = "Electrochimica Acta",
issn = "0013-4686",
publisher = "Elsevier Limited",
number = "20",

}

TY - JOUR

T1 - Response to the Commentary of Marcel Drüschler and Bernhard Roling on 'The interface between Au(1 1 1) and an ionic liquid'

AU - Pajkossy, T.

PY - 2011/8/1

Y1 - 2011/8/1

N2 - The metal/ionic liquid electrode impedance is practically resistive at the high frequency range of the usual electrochemical impedance spectroscopy measurements; the deviations are artefacts most probably due to the measurement system. Therefore the use of the interfacial capacitance representation of impedance spectra is further on suggested.

AB - The metal/ionic liquid electrode impedance is practically resistive at the high frequency range of the usual electrochemical impedance spectroscopy measurements; the deviations are artefacts most probably due to the measurement system. Therefore the use of the interfacial capacitance representation of impedance spectra is further on suggested.

KW - Capacitance

KW - Double layer

KW - Electrochemical impedance spectroscopy

KW - Equivalent circuit

KW - Ionic liquid

UR - http://www.scopus.com/inward/record.url?scp=80051544469&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80051544469&partnerID=8YFLogxK

U2 - 10.1016/j.electacta.2011.05.100

DO - 10.1016/j.electacta.2011.05.100

M3 - Article

AN - SCOPUS:80051544469

VL - 56

SP - 7246

EP - 7247

JO - Electrochimica Acta

JF - Electrochimica Acta

SN - 0013-4686

IS - 20

ER -