A háromdimenziós ultrahang-diagnosztika alkalmazásának lehetöségei a szülészet-nögyógyászatban.

A. Pál, G. Vajda, A. Bábinszki, L. Kovács

Research output: Article

1 Citation (Scopus)

Abstract

The authors report their experiences with 3 dimensional ultrasound technique applied in cases of 286 obstetrical and 35 gynecological examinations. Combison 530, 3 D ultrasound equipment was used. Pathological signs were found in 14 cases. The introduction of this technique has been increasing the diagnostic accuracy of prenatal and gynecological ultrasound examinations, and some malformations, that could have never been seen by "traditional" 2 D methods, can be visualized as well.

Original languageHungarian
Pages (from-to)2599-2602
Number of pages4
JournalOrvosi Hetilap
Volume138
Issue number41
Publication statusPublished - okt. 12 1997

Fingerprint

Gynecological Examination
Gynecology
Obstetrics
Ultrasonography
Equipment and Supplies

ASJC Scopus subject areas

  • Medicine(all)

Cite this

A háromdimenziós ultrahang-diagnosztika alkalmazásának lehetöségei a szülészet-nögyógyászatban. / Pál, A.; Vajda, G.; Bábinszki, A.; Kovács, L.

In: Orvosi Hetilap, Vol. 138, No. 41, 12.10.1997, p. 2599-2602.

Research output: Article

Pál, A. ; Vajda, G. ; Bábinszki, A. ; Kovács, L. / A háromdimenziós ultrahang-diagnosztika alkalmazásának lehetöségei a szülészet-nögyógyászatban. In: Orvosi Hetilap. 1997 ; Vol. 138, No. 41. pp. 2599-2602.
@article{2f1f91927613443395fdf971b2752cfa,
title = "A h{\'a}romdimenzi{\'o}s ultrahang-diagnosztika alkalmaz{\'a}s{\'a}nak lehet{\"o}s{\'e}gei a sz{\"u}l{\'e}szet-n{\"o}gy{\'o}gy{\'a}szatban.",
abstract = "The authors report their experiences with 3 dimensional ultrasound technique applied in cases of 286 obstetrical and 35 gynecological examinations. Combison 530, 3 D ultrasound equipment was used. Pathological signs were found in 14 cases. The introduction of this technique has been increasing the diagnostic accuracy of prenatal and gynecological ultrasound examinations, and some malformations, that could have never been seen by {"}traditional{"} 2 D methods, can be visualized as well.",
author = "A. P{\'a}l and G. Vajda and A. B{\'a}binszki and L. Kov{\'a}cs",
year = "1997",
month = "10",
day = "12",
language = "Hungarian",
volume = "138",
pages = "2599--2602",
journal = "Orvosi Hetilap",
issn = "0030-6002",
publisher = "Akademiai Kiado",
number = "41",

}

TY - JOUR

T1 - A háromdimenziós ultrahang-diagnosztika alkalmazásának lehetöségei a szülészet-nögyógyászatban.

AU - Pál, A.

AU - Vajda, G.

AU - Bábinszki, A.

AU - Kovács, L.

PY - 1997/10/12

Y1 - 1997/10/12

N2 - The authors report their experiences with 3 dimensional ultrasound technique applied in cases of 286 obstetrical and 35 gynecological examinations. Combison 530, 3 D ultrasound equipment was used. Pathological signs were found in 14 cases. The introduction of this technique has been increasing the diagnostic accuracy of prenatal and gynecological ultrasound examinations, and some malformations, that could have never been seen by "traditional" 2 D methods, can be visualized as well.

AB - The authors report their experiences with 3 dimensional ultrasound technique applied in cases of 286 obstetrical and 35 gynecological examinations. Combison 530, 3 D ultrasound equipment was used. Pathological signs were found in 14 cases. The introduction of this technique has been increasing the diagnostic accuracy of prenatal and gynecological ultrasound examinations, and some malformations, that could have never been seen by "traditional" 2 D methods, can be visualized as well.

UR - http://www.scopus.com/inward/record.url?scp=0031565738&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031565738&partnerID=8YFLogxK

M3 - Article

C2 - 9411329

AN - SCOPUS:0031565738

VL - 138

SP - 2599

EP - 2602

JO - Orvosi Hetilap

JF - Orvosi Hetilap

SN - 0030-6002

IS - 41

ER -