Injection techniques in dynamic flow-through analysis with electroanalytical sensors

Erno and #x030B; Pungor, Zsófia Fehér, G. Nagy, K. Tóth, G. Horvai, Miklós Gratzl

Research output: Article

74 Citations (Scopus)

Abstract

The theoretical and practical aspects of injection techniques used in flow-through systems with ion-selective electrodes and voltammetric detectors are discussed. Mathematical descriptions of the measuring systems based on the use of mixing chambers in the analytical channel are briefly outlined. The effects of different parameters on the analytical signals are described theoretically and experimentally. The methods developed for the evaluation of the analytical signals are presented in detail.

Original languageEnglish
Pages (from-to)1-24
Number of pages24
JournalAnalytica Chimica Acta
Volume109
Issue number1
DOIs
Publication statusPublished - aug. 1 1979

Fingerprint

Ion-Selective Electrodes
sensor
Detectors
Injections
Sensors
electrode
ion
analysis
detector
evaluation
effect
method
measuring
parameter

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Injection techniques in dynamic flow-through analysis with electroanalytical sensors. / Pungor, Erno and #x030B; Fehér, Zsófia; Nagy, G.; Tóth, K.; Horvai, G.; Gratzl, Miklós.

In: Analytica Chimica Acta, Vol. 109, No. 1, 01.08.1979, p. 1-24.

Research output: Article

Pungor, Erno and #x030B; ; Fehér, Zsófia ; Nagy, G. ; Tóth, K. ; Horvai, G. ; Gratzl, Miklós. / Injection techniques in dynamic flow-through analysis with electroanalytical sensors. In: Analytica Chimica Acta. 1979 ; Vol. 109, No. 1. pp. 1-24.
@article{084638c8642e4095bc9b91a0b9f6bdcc,
title = "Injection techniques in dynamic flow-through analysis with electroanalytical sensors",
abstract = "The theoretical and practical aspects of injection techniques used in flow-through systems with ion-selective electrodes and voltammetric detectors are discussed. Mathematical descriptions of the measuring systems based on the use of mixing chambers in the analytical channel are briefly outlined. The effects of different parameters on the analytical signals are described theoretically and experimentally. The methods developed for the evaluation of the analytical signals are presented in detail.",
author = "Pungor, {Erno and #x030B;} and Zs{\'o}fia Feh{\'e}r and G. Nagy and K. T{\'o}th and G. Horvai and Mikl{\'o}s Gratzl",
year = "1979",
month = "8",
day = "1",
doi = "10.1016/S0003-2670(01)84221-5",
language = "English",
volume = "109",
pages = "1--24",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Injection techniques in dynamic flow-through analysis with electroanalytical sensors

AU - Pungor, Erno and #x030B;

AU - Fehér, Zsófia

AU - Nagy, G.

AU - Tóth, K.

AU - Horvai, G.

AU - Gratzl, Miklós

PY - 1979/8/1

Y1 - 1979/8/1

N2 - The theoretical and practical aspects of injection techniques used in flow-through systems with ion-selective electrodes and voltammetric detectors are discussed. Mathematical descriptions of the measuring systems based on the use of mixing chambers in the analytical channel are briefly outlined. The effects of different parameters on the analytical signals are described theoretically and experimentally. The methods developed for the evaluation of the analytical signals are presented in detail.

AB - The theoretical and practical aspects of injection techniques used in flow-through systems with ion-selective electrodes and voltammetric detectors are discussed. Mathematical descriptions of the measuring systems based on the use of mixing chambers in the analytical channel are briefly outlined. The effects of different parameters on the analytical signals are described theoretically and experimentally. The methods developed for the evaluation of the analytical signals are presented in detail.

UR - http://www.scopus.com/inward/record.url?scp=0010335542&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0010335542&partnerID=8YFLogxK

U2 - 10.1016/S0003-2670(01)84221-5

DO - 10.1016/S0003-2670(01)84221-5

M3 - Article

AN - SCOPUS:0010335542

VL - 109

SP - 1

EP - 24

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 1

ER -