Szimulalt orthostasis okozta hemodinamikai valtozasok

L. Zoltan, R. Andreas, H. S.G. Helmut

Research output: Article

Abstract

INTRODUCTION - 'Lower body negative pressure' (LBNP, simulated orthostasis) is an experimental method to simulate orthostatic stress METHODS - The aim of this study was to quantitate hemodynamic and thoracic bioimpedance changes with four levels of LBNP (-15, -35, -55, -65 mmHg) in 7 healthy men in supine position 20 min before (pre-LBNP), 30 min during, and 20 min after suction as well as without suction (rest control). RESULTS - Thoracic bioimpedance computed stroke volume index continuously decreased with time by the end of simulated orthostasis of -15, -35, -55 and -65 mmHg. The decrease of cardiac index was largest at LBNP of -15 and -35, where the highest relative increase of total peripheral resistance index occurred. Mean arterial pressure did not change in any systematic way with lower LBNP levels, but increased at the end of LBNP -55 and -65. Heart rate remained unchanged at LBNP-15, but increased continuously with simulated orthostasis duration at higher levels by the end of LBNP-35, -55, and -65. Having finished simulated orthostasis, heart rate fell below pre-stimulus levels and also below rest control levels for ≥5 min; computed stroke volume index transiently returned to pre-stimulus levels, whereas mean arterial pressure increased above pre-LBNP level after finishing the stimulus. CONCLUSIONS - Different levels of lower body negative pressure produced quantitatively different time course and dose-response patterns and subjects remained non- hypotensive up to -65 mmHg suction. The heart rate was depressed after simulated orthostasis, while arterial blood pressure and impedance computed total peripheral resistance exceeded pre-stimulus levels indicating an altered cardiovascular (neuro-humoral) state after 30 min of simulated orthostasis.

Translated title of the contributionHemodynamic changes during simulated orthostasis
Original languageHungarian
Pages (from-to)422-431
Number of pages10
JournalLege Artis Medicinae
Volume10
Issue number5
Publication statusPublished - júl. 15 2000

Keywords

  • Autonomic reflexes
  • Cardiopulmonary baroreceptors
  • Central blood volume
  • Impedance cardiography
  • Lower body negative pressure (LBNP)

ASJC Scopus subject areas

  • Medicine(all)

Fingerprint Dive into the research topics of 'Szimulalt orthostasis okozta hemodinamikai valtozasok'. Together they form a unique fingerprint.

  • Cite this

    Zoltan, L., Andreas, R., & Helmut, H. S. G. (2000). Szimulalt orthostasis okozta hemodinamikai valtozasok. Lege Artis Medicinae, 10(5), 422-431.