Drug release from semisolid dosage forms: A comparison of two testing methods

E. Petró, T. L. Paál, I. Eros, A. S. Kenneth, G. Baki, I. Csóka

Research output: Article

4 Citations (Scopus)

Abstract

The aim of the present work was to extend our previous in-vitro drug release studies using semisolid dermatological bases with non-impregnated cellulose acetate membranes. A comparison of the performances of two apparatuses, the more commonly used Franz cell and the new modified USP (mini paddle with ointment holding cell) systems were applied to this work. Five different semisolid as well as two marketed preparations containing 1% diclofenac sodium were used. Complex, slightly non-linear release curves indicating sink conditions were found. This was explained by the co-diffusion of excipients modifying the characteristics of the membrane and the receiving medium dynamically. Although our test model is, as a rule, not suitable to establish an in-vivo-in-vitro correlation, good qualitative as well as quantitative correlations were found within some types of dermatological bases. The correlation between the results of the two in-vitro methods also depends on the type of semisolids studied. The release curve characteristics and the amount of diclofenac sodium released at 6 h were measured. Their repeatability and reproducibility were calculated. The slopes and Q-values were correlated with in-vivo data. In general, the modified USP method provided more precise results than the Franz cell method.

Original languageEnglish
Pages (from-to)330-336
Number of pages7
JournalPharmaceutical Development and Technology
Volume20
Issue number3
DOIs
Publication statusPublished - máj. 1 2015

Fingerprint

Dosage Forms
Diclofenac
Membranes
Excipients
Ointments
Drug Liberation
In Vitro Techniques

ASJC Scopus subject areas

  • Pharmaceutical Science

Cite this

Drug release from semisolid dosage forms : A comparison of two testing methods. / Petró, E.; Paál, T. L.; Eros, I.; Kenneth, A. S.; Baki, G.; Csóka, I.

In: Pharmaceutical Development and Technology, Vol. 20, No. 3, 01.05.2015, p. 330-336.

Research output: Article

Petró, E. ; Paál, T. L. ; Eros, I. ; Kenneth, A. S. ; Baki, G. ; Csóka, I. / Drug release from semisolid dosage forms : A comparison of two testing methods. In: Pharmaceutical Development and Technology. 2015 ; Vol. 20, No. 3. pp. 330-336.
@article{485ac2f293fc4ad38a29d6e3becbada4,
title = "Drug release from semisolid dosage forms: A comparison of two testing methods",
abstract = "The aim of the present work was to extend our previous in-vitro drug release studies using semisolid dermatological bases with non-impregnated cellulose acetate membranes. A comparison of the performances of two apparatuses, the more commonly used Franz cell and the new modified USP (mini paddle with ointment holding cell) systems were applied to this work. Five different semisolid as well as two marketed preparations containing 1{\%} diclofenac sodium were used. Complex, slightly non-linear release curves indicating sink conditions were found. This was explained by the co-diffusion of excipients modifying the characteristics of the membrane and the receiving medium dynamically. Although our test model is, as a rule, not suitable to establish an in-vivo-in-vitro correlation, good qualitative as well as quantitative correlations were found within some types of dermatological bases. The correlation between the results of the two in-vitro methods also depends on the type of semisolids studied. The release curve characteristics and the amount of diclofenac sodium released at 6 h were measured. Their repeatability and reproducibility were calculated. The slopes and Q-values were correlated with in-vivo data. In general, the modified USP method provided more precise results than the Franz cell method.",
keywords = "Franz cell, in vitro, in vivo, Mini-paddle, Modified holding cell, Skin penetration",
author = "E. Petr{\'o} and Pa{\'a}l, {T. L.} and I. Eros and Kenneth, {A. S.} and G. Baki and I. Cs{\'o}ka",
year = "2015",
month = "5",
day = "1",
doi = "10.3109/10837450.2013.867446",
language = "English",
volume = "20",
pages = "330--336",
journal = "Pharmaceutical Development and Technology",
issn = "1083-7450",
publisher = "Informa Healthcare",
number = "3",

}

TY - JOUR

T1 - Drug release from semisolid dosage forms

T2 - A comparison of two testing methods

AU - Petró, E.

AU - Paál, T. L.

AU - Eros, I.

AU - Kenneth, A. S.

AU - Baki, G.

AU - Csóka, I.

PY - 2015/5/1

Y1 - 2015/5/1

N2 - The aim of the present work was to extend our previous in-vitro drug release studies using semisolid dermatological bases with non-impregnated cellulose acetate membranes. A comparison of the performances of two apparatuses, the more commonly used Franz cell and the new modified USP (mini paddle with ointment holding cell) systems were applied to this work. Five different semisolid as well as two marketed preparations containing 1% diclofenac sodium were used. Complex, slightly non-linear release curves indicating sink conditions were found. This was explained by the co-diffusion of excipients modifying the characteristics of the membrane and the receiving medium dynamically. Although our test model is, as a rule, not suitable to establish an in-vivo-in-vitro correlation, good qualitative as well as quantitative correlations were found within some types of dermatological bases. The correlation between the results of the two in-vitro methods also depends on the type of semisolids studied. The release curve characteristics and the amount of diclofenac sodium released at 6 h were measured. Their repeatability and reproducibility were calculated. The slopes and Q-values were correlated with in-vivo data. In general, the modified USP method provided more precise results than the Franz cell method.

AB - The aim of the present work was to extend our previous in-vitro drug release studies using semisolid dermatological bases with non-impregnated cellulose acetate membranes. A comparison of the performances of two apparatuses, the more commonly used Franz cell and the new modified USP (mini paddle with ointment holding cell) systems were applied to this work. Five different semisolid as well as two marketed preparations containing 1% diclofenac sodium were used. Complex, slightly non-linear release curves indicating sink conditions were found. This was explained by the co-diffusion of excipients modifying the characteristics of the membrane and the receiving medium dynamically. Although our test model is, as a rule, not suitable to establish an in-vivo-in-vitro correlation, good qualitative as well as quantitative correlations were found within some types of dermatological bases. The correlation between the results of the two in-vitro methods also depends on the type of semisolids studied. The release curve characteristics and the amount of diclofenac sodium released at 6 h were measured. Their repeatability and reproducibility were calculated. The slopes and Q-values were correlated with in-vivo data. In general, the modified USP method provided more precise results than the Franz cell method.

KW - Franz cell

KW - in vitro

KW - in vivo

KW - Mini-paddle

KW - Modified holding cell

KW - Skin penetration

UR - http://www.scopus.com/inward/record.url?scp=84927632723&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927632723&partnerID=8YFLogxK

U2 - 10.3109/10837450.2013.867446

DO - 10.3109/10837450.2013.867446

M3 - Article

C2 - 24328512

AN - SCOPUS:84927632723

VL - 20

SP - 330

EP - 336

JO - Pharmaceutical Development and Technology

JF - Pharmaceutical Development and Technology

SN - 1083-7450

IS - 3

ER -