Comparison of Tearscope-plus versus slit lamp measurements of inferior tear meniscus height in normal individuals

Eszter Fodor, Krisztina Hagyó, Miklós Resch, Dóra Somodi, J. Németh

Research output: Article

11 Citations (Scopus)

Abstract

Purpose. To measure the lower tear meniscus height (LTMH) with image by Tearscope and using slit-lamp biomicroscopy with or without fluorescein staining. Methods. The lower tear meniscus height was measured in 31 eyes of 31 healthy volunteers (mean age 31.29 years; SD 4.83) with Tearscope and slit lamp with and without fluorescein staining. The mean values of LTMH were measured with different methods and the repeatability of the measurements was statistically analyzed. Measurement of fluorescein tear film break up time (FBUT) and Schirmer test were also performed. Results. The mean value of LTMH was 0.21 mm (SD 0.07) with Tearscope, 0.20 mm (SD 0.06) with slit lamp without fluorescein staining, and 0.23 mm (SD 0.07) with fluorescein staining. There was no significant difference among the mean values of LTMH with these 3 different measurement methods. Based on the random effect analysis of variance (p=0.05), the measurements were more repeatable with Tearscope-plus than with the other 2 methods. No correlation was found between the LTMH and the results of Schirmer test or FBUT. Conclusions. The LTMH could be reliably measured with slit-lamp biomicroscopy without staining, but the measurements were more repeatable with Tearscope.

Original languageEnglish
Pages (from-to)819-824
Number of pages6
JournalEuropean Journal of Ophthalmology
Volume20
Issue number5
Publication statusPublished - szept. 2010

Fingerprint

Tears
Fluorescein
Staining and Labeling
Meniscus
Slit Lamp
Analysis of Variance
Healthy Volunteers

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Comparison of Tearscope-plus versus slit lamp measurements of inferior tear meniscus height in normal individuals. / Fodor, Eszter; Hagyó, Krisztina; Resch, Miklós; Somodi, Dóra; Németh, J.

In: European Journal of Ophthalmology, Vol. 20, No. 5, 09.2010, p. 819-824.

Research output: Article

Fodor, Eszter ; Hagyó, Krisztina ; Resch, Miklós ; Somodi, Dóra ; Németh, J. / Comparison of Tearscope-plus versus slit lamp measurements of inferior tear meniscus height in normal individuals. In: European Journal of Ophthalmology. 2010 ; Vol. 20, No. 5. pp. 819-824.
@article{b0aad396a6c04afd98622facc82a7861,
title = "Comparison of Tearscope-plus versus slit lamp measurements of inferior tear meniscus height in normal individuals",
abstract = "Purpose. To measure the lower tear meniscus height (LTMH) with image by Tearscope and using slit-lamp biomicroscopy with or without fluorescein staining. Methods. The lower tear meniscus height was measured in 31 eyes of 31 healthy volunteers (mean age 31.29 years; SD 4.83) with Tearscope and slit lamp with and without fluorescein staining. The mean values of LTMH were measured with different methods and the repeatability of the measurements was statistically analyzed. Measurement of fluorescein tear film break up time (FBUT) and Schirmer test were also performed. Results. The mean value of LTMH was 0.21 mm (SD 0.07) with Tearscope, 0.20 mm (SD 0.06) with slit lamp without fluorescein staining, and 0.23 mm (SD 0.07) with fluorescein staining. There was no significant difference among the mean values of LTMH with these 3 different measurement methods. Based on the random effect analysis of variance (p=0.05), the measurements were more repeatable with Tearscope-plus than with the other 2 methods. No correlation was found between the LTMH and the results of Schirmer test or FBUT. Conclusions. The LTMH could be reliably measured with slit-lamp biomicroscopy without staining, but the measurements were more repeatable with Tearscope.",
keywords = "Slit lamp, Tear meniscus height, Tearscope",
author = "Eszter Fodor and Krisztina Hagy{\'o} and Mikl{\'o}s Resch and D{\'o}ra Somodi and J. N{\'e}meth",
year = "2010",
month = "9",
language = "English",
volume = "20",
pages = "819--824",
journal = "European Journal of Ophthalmology",
issn = "1120-6721",
publisher = "Wichtig Publishing",
number = "5",

}

TY - JOUR

T1 - Comparison of Tearscope-plus versus slit lamp measurements of inferior tear meniscus height in normal individuals

AU - Fodor, Eszter

AU - Hagyó, Krisztina

AU - Resch, Miklós

AU - Somodi, Dóra

AU - Németh, J.

PY - 2010/9

Y1 - 2010/9

N2 - Purpose. To measure the lower tear meniscus height (LTMH) with image by Tearscope and using slit-lamp biomicroscopy with or without fluorescein staining. Methods. The lower tear meniscus height was measured in 31 eyes of 31 healthy volunteers (mean age 31.29 years; SD 4.83) with Tearscope and slit lamp with and without fluorescein staining. The mean values of LTMH were measured with different methods and the repeatability of the measurements was statistically analyzed. Measurement of fluorescein tear film break up time (FBUT) and Schirmer test were also performed. Results. The mean value of LTMH was 0.21 mm (SD 0.07) with Tearscope, 0.20 mm (SD 0.06) with slit lamp without fluorescein staining, and 0.23 mm (SD 0.07) with fluorescein staining. There was no significant difference among the mean values of LTMH with these 3 different measurement methods. Based on the random effect analysis of variance (p=0.05), the measurements were more repeatable with Tearscope-plus than with the other 2 methods. No correlation was found between the LTMH and the results of Schirmer test or FBUT. Conclusions. The LTMH could be reliably measured with slit-lamp biomicroscopy without staining, but the measurements were more repeatable with Tearscope.

AB - Purpose. To measure the lower tear meniscus height (LTMH) with image by Tearscope and using slit-lamp biomicroscopy with or without fluorescein staining. Methods. The lower tear meniscus height was measured in 31 eyes of 31 healthy volunteers (mean age 31.29 years; SD 4.83) with Tearscope and slit lamp with and without fluorescein staining. The mean values of LTMH were measured with different methods and the repeatability of the measurements was statistically analyzed. Measurement of fluorescein tear film break up time (FBUT) and Schirmer test were also performed. Results. The mean value of LTMH was 0.21 mm (SD 0.07) with Tearscope, 0.20 mm (SD 0.06) with slit lamp without fluorescein staining, and 0.23 mm (SD 0.07) with fluorescein staining. There was no significant difference among the mean values of LTMH with these 3 different measurement methods. Based on the random effect analysis of variance (p=0.05), the measurements were more repeatable with Tearscope-plus than with the other 2 methods. No correlation was found between the LTMH and the results of Schirmer test or FBUT. Conclusions. The LTMH could be reliably measured with slit-lamp biomicroscopy without staining, but the measurements were more repeatable with Tearscope.

KW - Slit lamp

KW - Tear meniscus height

KW - Tearscope

UR - http://www.scopus.com/inward/record.url?scp=77957564307&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77957564307&partnerID=8YFLogxK

M3 - Article

C2 - 20213618

AN - SCOPUS:77957564307

VL - 20

SP - 819

EP - 824

JO - European Journal of Ophthalmology

JF - European Journal of Ophthalmology

SN - 1120-6721

IS - 5

ER -