Chromogenic calix[4]arene derivative was synthesized and tested as an ionophore for potentiometric and optical sensors. Distinct sodium selectivity was observed with this ionophore based, plasticized PVC membranes in potentiometric measurements suggesting their utility for biological applications. Optode membranes exhibited sodium sensitivity in the 5 × 10-2 -10-4 M concentration range. The optical sensitivity was improved by the use of an internal, lipophilic base (TDDA). The operation of the optical sensor is in accordance with the ion-exchange theory.

Original languageEnglish
Pages (from-to)1041-1049
Number of pages9
JournalTalanta
Volume41
Issue number6
DOIs
Publication statusPublished - 1994

Fingerprint

Potentiometric sensors
Chromogenics
Ionophores
Optical sensors
Sodium
Membranes
Ion Exchange
Polyvinyl Chloride
Ion exchange
Derivatives
calix(4)arene

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Chromogenic calix[4]arene as ionophore for potentiometric and optical sensors. / Tóth, K.; Thu Lan, Bui Thi; Jeney, Judit; Horváth, Mária; Bitter, I.; Grün, A.; Ágai, B.; Tódke, László.

In: Talanta, Vol. 41, No. 6, 1994, p. 1041-1049.

Research output: Article

Tóth, K. ; Thu Lan, Bui Thi ; Jeney, Judit ; Horváth, Mária ; Bitter, I. ; Grün, A. ; Ágai, B. ; Tódke, László. / Chromogenic calix[4]arene as ionophore for potentiometric and optical sensors. In: Talanta. 1994 ; Vol. 41, No. 6. pp. 1041-1049.
@article{44350b9cb8294dc59651b8c08845dc63,
title = "Chromogenic calix[4]arene as ionophore for potentiometric and optical sensors",
abstract = "Chromogenic calix[4]arene derivative was synthesized and tested as an ionophore for potentiometric and optical sensors. Distinct sodium selectivity was observed with this ionophore based, plasticized PVC membranes in potentiometric measurements suggesting their utility for biological applications. Optode membranes exhibited sodium sensitivity in the 5 × 10-2 -10-4 M concentration range. The optical sensitivity was improved by the use of an internal, lipophilic base (TDDA). The operation of the optical sensor is in accordance with the ion-exchange theory.",
author = "K. T{\'o}th and {Thu Lan}, {Bui Thi} and Judit Jeney and M{\'a}ria Horv{\'a}th and I. Bitter and A. Gr{\"u}n and B. {\'A}gai and L{\'a}szl{\'o} T{\'o}dke",
year = "1994",
doi = "10.1016/0039-9140(94)E0094-8",
language = "English",
volume = "41",
pages = "1041--1049",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "6",

}

TY - JOUR

T1 - Chromogenic calix[4]arene as ionophore for potentiometric and optical sensors

AU - Tóth, K.

AU - Thu Lan, Bui Thi

AU - Jeney, Judit

AU - Horváth, Mária

AU - Bitter, I.

AU - Grün, A.

AU - Ágai, B.

AU - Tódke, László

PY - 1994

Y1 - 1994

N2 - Chromogenic calix[4]arene derivative was synthesized and tested as an ionophore for potentiometric and optical sensors. Distinct sodium selectivity was observed with this ionophore based, plasticized PVC membranes in potentiometric measurements suggesting their utility for biological applications. Optode membranes exhibited sodium sensitivity in the 5 × 10-2 -10-4 M concentration range. The optical sensitivity was improved by the use of an internal, lipophilic base (TDDA). The operation of the optical sensor is in accordance with the ion-exchange theory.

AB - Chromogenic calix[4]arene derivative was synthesized and tested as an ionophore for potentiometric and optical sensors. Distinct sodium selectivity was observed with this ionophore based, plasticized PVC membranes in potentiometric measurements suggesting their utility for biological applications. Optode membranes exhibited sodium sensitivity in the 5 × 10-2 -10-4 M concentration range. The optical sensitivity was improved by the use of an internal, lipophilic base (TDDA). The operation of the optical sensor is in accordance with the ion-exchange theory.

UR - http://www.scopus.com/inward/record.url?scp=43949148231&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=43949148231&partnerID=8YFLogxK

U2 - 10.1016/0039-9140(94)E0094-8

DO - 10.1016/0039-9140(94)E0094-8

M3 - Article

AN - SCOPUS:43949148231

VL - 41

SP - 1041

EP - 1049

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 6

ER -