Calibration of a DSSSD detector with radioactive sources

V. Guadilla, J. L. Taín, J. Agramunt, A. Algora, C. Domingo-Pardo, B. Rubio

Research output: Conference contribution

Abstract

The energy calibration of a DSSSD is carried out with the spectra produced by a 207Bi conversion electron source, a 137Cs gamma source and a 239Pu/241Am/244Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.

Original languageEnglish
Title of host publicationAIP Conference Proceedings
Pages173-174
Number of pages2
Volume1541
DOIs
Publication statusPublished - 2013
EventLa Rabida 2012 International Scientific Meeting on Nuclear Physics - Basic Concepts in Nuclear Physics: Theory, Experiments, and Applications - La Rabida, Spain
Duration: szept. 9 2012szept. 13 2012

Other

OtherLa Rabida 2012 International Scientific Meeting on Nuclear Physics - Basic Concepts in Nuclear Physics: Theory, Experiments, and Applications
CountrySpain
CityLa Rabida
Period9/9/129/13/12

Fingerprint

pulse generators
electron sources
detectors
dynamic range
strip
energy

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Guadilla, V., Taín, J. L., Agramunt, J., Algora, A., Domingo-Pardo, C., & Rubio, B. (2013). Calibration of a DSSSD detector with radioactive sources. In AIP Conference Proceedings (Vol. 1541, pp. 173-174) https://doi.org/10.1063/1.4810833

Calibration of a DSSSD detector with radioactive sources. / Guadilla, V.; Taín, J. L.; Agramunt, J.; Algora, A.; Domingo-Pardo, C.; Rubio, B.

AIP Conference Proceedings. Vol. 1541 2013. p. 173-174.

Research output: Conference contribution

Guadilla, V, Taín, JL, Agramunt, J, Algora, A, Domingo-Pardo, C & Rubio, B 2013, Calibration of a DSSSD detector with radioactive sources. in AIP Conference Proceedings. vol. 1541, pp. 173-174, La Rabida 2012 International Scientific Meeting on Nuclear Physics - Basic Concepts in Nuclear Physics: Theory, Experiments, and Applications, La Rabida, Spain, 9/9/12. https://doi.org/10.1063/1.4810833
Guadilla V, Taín JL, Agramunt J, Algora A, Domingo-Pardo C, Rubio B. Calibration of a DSSSD detector with radioactive sources. In AIP Conference Proceedings. Vol. 1541. 2013. p. 173-174 https://doi.org/10.1063/1.4810833
Guadilla, V. ; Taín, J. L. ; Agramunt, J. ; Algora, A. ; Domingo-Pardo, C. ; Rubio, B. / Calibration of a DSSSD detector with radioactive sources. AIP Conference Proceedings. Vol. 1541 2013. pp. 173-174
@inproceedings{8a1d89c3692b4c678846faefa3bf443d,
title = "Calibration of a DSSSD detector with radioactive sources",
abstract = "The energy calibration of a DSSSD is carried out with the spectra produced by a 207Bi conversion electron source, a 137Cs gamma source and a 239Pu/241Am/244Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.",
keywords = "DSSSD, energy calibration, fragmentation experiments",
author = "V. Guadilla and Ta{\'i}n, {J. L.} and J. Agramunt and A. Algora and C. Domingo-Pardo and B. Rubio",
year = "2013",
doi = "10.1063/1.4810833",
language = "English",
isbn = "9780735411654",
volume = "1541",
pages = "173--174",
booktitle = "AIP Conference Proceedings",

}

TY - GEN

T1 - Calibration of a DSSSD detector with radioactive sources

AU - Guadilla, V.

AU - Taín, J. L.

AU - Agramunt, J.

AU - Algora, A.

AU - Domingo-Pardo, C.

AU - Rubio, B.

PY - 2013

Y1 - 2013

N2 - The energy calibration of a DSSSD is carried out with the spectra produced by a 207Bi conversion electron source, a 137Cs gamma source and a 239Pu/241Am/244Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.

AB - The energy calibration of a DSSSD is carried out with the spectra produced by a 207Bi conversion electron source, a 137Cs gamma source and a 239Pu/241Am/244Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.

KW - DSSSD

KW - energy calibration

KW - fragmentation experiments

UR - http://www.scopus.com/inward/record.url?scp=84879779238&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84879779238&partnerID=8YFLogxK

U2 - 10.1063/1.4810833

DO - 10.1063/1.4810833

M3 - Conference contribution

AN - SCOPUS:84879779238

SN - 9780735411654

VL - 1541

SP - 173

EP - 174

BT - AIP Conference Proceedings

ER -