Wavelength calibration in conventional SANS setup with a mechanical velocity selector

L. Almásy, A. Len, M. Markó, E. Rétfalvi

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

In the conventional setup of a small-angle neutron scattering instrument a nearly monochromatic neutron beam is formed by means of a mechanical velocity selector. We studied the influence of the wavelength distribution in the incident beam on the wavelength of the neutrons reaching the sample. The assumption that the wavelength spectrum behind the selector equals to the product of the incident spectrum of the thermalized neutrons and the transmission window of the selector predicts satisfactorily the wavelength measured at sample position. An approximate relation is given between the effective wavelength and the selector rotation speed. The described method of wavelength calibration can improve the precision of size determination in SANS experiment.

Original languageEnglish
Pages (from-to)211-216
Number of pages6
JournalZeitschrift fur Kristallographie
Volume221
Issue numberSUPPL. 23
Publication statusPublished - 2006

Fingerprint

selectors
Calibration
Wavelength
wavelengths
Neutrons
Size determination
size determination
neutrons
Neutron beams
neutron beams
Neutron scattering
neutron scattering
products
Experiments

Keywords

  • Silver behenate
  • Small-angle neutron scattering
  • Velocity selector
  • Wavelength calibration

ASJC Scopus subject areas

  • Condensed Matter Physics

Cite this

Wavelength calibration in conventional SANS setup with a mechanical velocity selector. / Almásy, L.; Len, A.; Markó, M.; Rétfalvi, E.

In: Zeitschrift fur Kristallographie, Vol. 221, No. SUPPL. 23, 2006, p. 211-216.

Research output: Contribution to journalArticle

Almásy, L. ; Len, A. ; Markó, M. ; Rétfalvi, E. / Wavelength calibration in conventional SANS setup with a mechanical velocity selector. In: Zeitschrift fur Kristallographie. 2006 ; Vol. 221, No. SUPPL. 23. pp. 211-216.
@article{cbc643e63afd4fab9b0961d414fa19fd,
title = "Wavelength calibration in conventional SANS setup with a mechanical velocity selector",
abstract = "In the conventional setup of a small-angle neutron scattering instrument a nearly monochromatic neutron beam is formed by means of a mechanical velocity selector. We studied the influence of the wavelength distribution in the incident beam on the wavelength of the neutrons reaching the sample. The assumption that the wavelength spectrum behind the selector equals to the product of the incident spectrum of the thermalized neutrons and the transmission window of the selector predicts satisfactorily the wavelength measured at sample position. An approximate relation is given between the effective wavelength and the selector rotation speed. The described method of wavelength calibration can improve the precision of size determination in SANS experiment.",
keywords = "Silver behenate, Small-angle neutron scattering, Velocity selector, Wavelength calibration",
author = "L. Alm{\'a}sy and A. Len and M. Mark{\'o} and E. R{\'e}tfalvi",
year = "2006",
language = "English",
volume = "221",
pages = "211--216",
journal = "Zeitschfrift fur Kristallographie",
issn = "1433-7266",
publisher = "R. Oldenbourg",
number = "SUPPL. 23",

}

TY - JOUR

T1 - Wavelength calibration in conventional SANS setup with a mechanical velocity selector

AU - Almásy, L.

AU - Len, A.

AU - Markó, M.

AU - Rétfalvi, E.

PY - 2006

Y1 - 2006

N2 - In the conventional setup of a small-angle neutron scattering instrument a nearly monochromatic neutron beam is formed by means of a mechanical velocity selector. We studied the influence of the wavelength distribution in the incident beam on the wavelength of the neutrons reaching the sample. The assumption that the wavelength spectrum behind the selector equals to the product of the incident spectrum of the thermalized neutrons and the transmission window of the selector predicts satisfactorily the wavelength measured at sample position. An approximate relation is given between the effective wavelength and the selector rotation speed. The described method of wavelength calibration can improve the precision of size determination in SANS experiment.

AB - In the conventional setup of a small-angle neutron scattering instrument a nearly monochromatic neutron beam is formed by means of a mechanical velocity selector. We studied the influence of the wavelength distribution in the incident beam on the wavelength of the neutrons reaching the sample. The assumption that the wavelength spectrum behind the selector equals to the product of the incident spectrum of the thermalized neutrons and the transmission window of the selector predicts satisfactorily the wavelength measured at sample position. An approximate relation is given between the effective wavelength and the selector rotation speed. The described method of wavelength calibration can improve the precision of size determination in SANS experiment.

KW - Silver behenate

KW - Small-angle neutron scattering

KW - Velocity selector

KW - Wavelength calibration

UR - http://www.scopus.com/inward/record.url?scp=33845793423&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845793423&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:33845793423

VL - 221

SP - 211

EP - 216

JO - Zeitschfrift fur Kristallographie

JF - Zeitschfrift fur Kristallographie

SN - 1433-7266

IS - SUPPL. 23

ER -