Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes

Theodore L. Economopoulos, Pantelis A. Asvestas, George K. Matsopoulos, Balint Molnar, P. Windisch

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A methodology is presented for registering threedimensional preoperative and postoperative CT scan volumes and for evaluating their differences in selected areas of interest. The proposed method was applied to CT cone beam data from ten patients in order to assess the volume of augmented bone in the alveolar region. A 3D affine model was used to align the preoperative and postoperative data. The differences between the aligned sets were assessed through subtraction radiography. The volume of the differences was finally evaluated by defining regions of interest in each slice of the subtracted 3D data. Both quantitative and qualitative results were obtained after applying the method to all sets. The effectiveness of the volumetric assessment algorithm was verified by applying the algorithm to an object of known volume.

Original languageEnglish
Title of host publicationProceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB
DOIs
Publication statusPublished - 2010
Event10th International Conference on Information Technology and Applications in Biomedicine: Emerging Technologies for Patient Specific Healthcare, ITAB 2010 - Corfu, Greece
Duration: Nov 2 2010Nov 5 2010

Other

Other10th International Conference on Information Technology and Applications in Biomedicine: Emerging Technologies for Patient Specific Healthcare, ITAB 2010
CountryGreece
CityCorfu
Period11/2/1011/5/10

Fingerprint

Computerized tomography
Radiography
Cones
Bone

ASJC Scopus subject areas

  • Computer Science Applications
  • Biomedical Engineering

Cite this

Economopoulos, T. L., Asvestas, P. A., Matsopoulos, G. K., Molnar, B., & Windisch, P. (2010). Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes. In Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB [5687753] https://doi.org/10.1109/ITAB.2010.5687753

Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes. / Economopoulos, Theodore L.; Asvestas, Pantelis A.; Matsopoulos, George K.; Molnar, Balint; Windisch, P.

Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB. 2010. 5687753.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Economopoulos, TL, Asvestas, PA, Matsopoulos, GK, Molnar, B & Windisch, P 2010, Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes. in Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB., 5687753, 10th International Conference on Information Technology and Applications in Biomedicine: Emerging Technologies for Patient Specific Healthcare, ITAB 2010, Corfu, Greece, 11/2/10. https://doi.org/10.1109/ITAB.2010.5687753
Economopoulos TL, Asvestas PA, Matsopoulos GK, Molnar B, Windisch P. Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes. In Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB. 2010. 5687753 https://doi.org/10.1109/ITAB.2010.5687753
Economopoulos, Theodore L. ; Asvestas, Pantelis A. ; Matsopoulos, George K. ; Molnar, Balint ; Windisch, P. / Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes. Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB. 2010.
@inproceedings{24d9ab273ff5478f9dbf1efb4fa98073,
title = "Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes",
abstract = "A methodology is presented for registering threedimensional preoperative and postoperative CT scan volumes and for evaluating their differences in selected areas of interest. The proposed method was applied to CT cone beam data from ten patients in order to assess the volume of augmented bone in the alveolar region. A 3D affine model was used to align the preoperative and postoperative data. The differences between the aligned sets were assessed through subtraction radiography. The volume of the differences was finally evaluated by defining regions of interest in each slice of the subtracted 3D data. Both quantitative and qualitative results were obtained after applying the method to all sets. The effectiveness of the volumetric assessment algorithm was verified by applying the algorithm to an object of known volume.",
author = "Economopoulos, {Theodore L.} and Asvestas, {Pantelis A.} and Matsopoulos, {George K.} and Balint Molnar and P. Windisch",
year = "2010",
doi = "10.1109/ITAB.2010.5687753",
language = "English",
isbn = "9781424465606",
booktitle = "Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB",

}

TY - GEN

T1 - Volumetric difference evaluation of registered three-dimensional preoperative and postoperative CT volumes

AU - Economopoulos, Theodore L.

AU - Asvestas, Pantelis A.

AU - Matsopoulos, George K.

AU - Molnar, Balint

AU - Windisch, P.

PY - 2010

Y1 - 2010

N2 - A methodology is presented for registering threedimensional preoperative and postoperative CT scan volumes and for evaluating their differences in selected areas of interest. The proposed method was applied to CT cone beam data from ten patients in order to assess the volume of augmented bone in the alveolar region. A 3D affine model was used to align the preoperative and postoperative data. The differences between the aligned sets were assessed through subtraction radiography. The volume of the differences was finally evaluated by defining regions of interest in each slice of the subtracted 3D data. Both quantitative and qualitative results were obtained after applying the method to all sets. The effectiveness of the volumetric assessment algorithm was verified by applying the algorithm to an object of known volume.

AB - A methodology is presented for registering threedimensional preoperative and postoperative CT scan volumes and for evaluating their differences in selected areas of interest. The proposed method was applied to CT cone beam data from ten patients in order to assess the volume of augmented bone in the alveolar region. A 3D affine model was used to align the preoperative and postoperative data. The differences between the aligned sets were assessed through subtraction radiography. The volume of the differences was finally evaluated by defining regions of interest in each slice of the subtracted 3D data. Both quantitative and qualitative results were obtained after applying the method to all sets. The effectiveness of the volumetric assessment algorithm was verified by applying the algorithm to an object of known volume.

UR - http://www.scopus.com/inward/record.url?scp=79951605028&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951605028&partnerID=8YFLogxK

U2 - 10.1109/ITAB.2010.5687753

DO - 10.1109/ITAB.2010.5687753

M3 - Conference contribution

SN - 9781424465606

BT - Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB

ER -