UV-Spektrophotometer-Detektor für Hochdruck-Flüssigkeits-Chromatographie

Translated title of the contribution: Ultraviolet-detector for high-performance liquid chromatography

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A high-performance u.v. detector has been developed to monitor UV absorbing compounds separated by HPLC. It consists of a modified Beckman DU Spectrophotometer fitted with 1 cm path length flow-through absorption cell with internal volume 8 mm3. The detector operates over the complete UV region with a full-scale sensitivity of 0.01 absorbance units. Short term noise is less than ±0.0002 absorbance units. Dirft over a 2 hour period is 0.0005 absorbance units. The range of linearity of the detector is 2.54 O.D.

Original languageGerman
Pages (from-to)52-53
Number of pages2
JournalChromatographia
Volume12
Issue number1
DOIs
Publication statusPublished - Jan 1979

Fingerprint

Ultraviolet detectors
High performance liquid chromatography
Noise
High Pressure Liquid Chromatography
Detectors
Spectrophotometers

ASJC Scopus subject areas

  • Analytical Chemistry
  • Clinical Biochemistry

Cite this

UV-Spektrophotometer-Detektor für Hochdruck-Flüssigkeits-Chromatographie. / Ohmacht, R.

In: Chromatographia, Vol. 12, No. 1, 01.1979, p. 52-53.

Research output: Contribution to journalArticle

@article{b35e8d164b5442189397422a7593bd1c,
title = "UV-Spektrophotometer-Detektor f{\"u}r Hochdruck-Fl{\"u}ssigkeits-Chromatographie",
abstract = "A high-performance u.v. detector has been developed to monitor UV absorbing compounds separated by HPLC. It consists of a modified Beckman DU Spectrophotometer fitted with 1 cm path length flow-through absorption cell with internal volume 8 mm3. The detector operates over the complete UV region with a full-scale sensitivity of 0.01 absorbance units. Short term noise is less than ±0.0002 absorbance units. Dirft over a 2 hour period is 0.0005 absorbance units. The range of linearity of the detector is 2.54 O.D.",
author = "R. Ohmacht",
year = "1979",
month = "1",
doi = "10.1007/BF02271602",
language = "German",
volume = "12",
pages = "52--53",
journal = "Chromatographia",
issn = "0009-5893",
publisher = "Springer Vieweg",
number = "1",

}

TY - JOUR

T1 - UV-Spektrophotometer-Detektor für Hochdruck-Flüssigkeits-Chromatographie

AU - Ohmacht, R.

PY - 1979/1

Y1 - 1979/1

N2 - A high-performance u.v. detector has been developed to monitor UV absorbing compounds separated by HPLC. It consists of a modified Beckman DU Spectrophotometer fitted with 1 cm path length flow-through absorption cell with internal volume 8 mm3. The detector operates over the complete UV region with a full-scale sensitivity of 0.01 absorbance units. Short term noise is less than ±0.0002 absorbance units. Dirft over a 2 hour period is 0.0005 absorbance units. The range of linearity of the detector is 2.54 O.D.

AB - A high-performance u.v. detector has been developed to monitor UV absorbing compounds separated by HPLC. It consists of a modified Beckman DU Spectrophotometer fitted with 1 cm path length flow-through absorption cell with internal volume 8 mm3. The detector operates over the complete UV region with a full-scale sensitivity of 0.01 absorbance units. Short term noise is less than ±0.0002 absorbance units. Dirft over a 2 hour period is 0.0005 absorbance units. The range of linearity of the detector is 2.54 O.D.

UR - http://www.scopus.com/inward/record.url?scp=34250271695&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34250271695&partnerID=8YFLogxK

U2 - 10.1007/BF02271602

DO - 10.1007/BF02271602

M3 - Article

AN - SCOPUS:34250271695

VL - 12

SP - 52

EP - 53

JO - Chromatographia

JF - Chromatographia

SN - 0009-5893

IS - 1

ER -