Ultrasound-guided aspiration in suspected sepsis of resection arthroplasty of the hip joint

K. Földes, P. Bálint, G. Bálint, W. Watson Buchanan

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

The authors described 17 patients who had had resection arthroplasty of the hip and who were suspected of having an infection. The resection arthroplasties had been performed for previous infection. All the patients were studied by ultrasonography to detect effusion in the pseudoarticular space. Thirteen of the 17 patients were found to have an effusion by ultrasonography. Fluid was obtained in 9 of the 13 patients by ultrasonographic-guided aspiration. The mean aspirated volume was 3 ml (range 1-25 ml). Five of the 9 aspirates proved to be septic. The echopattern in all but one of those five with sepsis was nonechofree. Of four other patients in whom it was not possible to aspirate fluid lavage of the pseudoarticular space one yielded a positive culture. The role of ultrasonography in the diagnosis and management of patients who have undergone resection arthroplasty of the hip and who are suspected of having an infected pseudoarticular space is discussed.

Original languageEnglish
Pages (from-to)327-329
Number of pages3
JournalClinical Rheumatology
Volume14
Issue number3
DOIs
Publication statusPublished - May 1995

Fingerprint

Hip Joint
Arthroplasty
Sepsis
Ultrasonography
Hip
Therapeutic Irrigation
Infection

Keywords

  • Resection Arthroplasty of Hip Joint
  • Sepsis
  • Ultrasonography

ASJC Scopus subject areas

  • Rheumatology
  • Immunology

Cite this

Ultrasound-guided aspiration in suspected sepsis of resection arthroplasty of the hip joint. / Földes, K.; Bálint, P.; Bálint, G.; Buchanan, W. Watson.

In: Clinical Rheumatology, Vol. 14, No. 3, 05.1995, p. 327-329.

Research output: Contribution to journalArticle

@article{9a5ffb5c504b4873b8370edca4fedf59,
title = "Ultrasound-guided aspiration in suspected sepsis of resection arthroplasty of the hip joint",
abstract = "The authors described 17 patients who had had resection arthroplasty of the hip and who were suspected of having an infection. The resection arthroplasties had been performed for previous infection. All the patients were studied by ultrasonography to detect effusion in the pseudoarticular space. Thirteen of the 17 patients were found to have an effusion by ultrasonography. Fluid was obtained in 9 of the 13 patients by ultrasonographic-guided aspiration. The mean aspirated volume was 3 ml (range 1-25 ml). Five of the 9 aspirates proved to be septic. The echopattern in all but one of those five with sepsis was nonechofree. Of four other patients in whom it was not possible to aspirate fluid lavage of the pseudoarticular space one yielded a positive culture. The role of ultrasonography in the diagnosis and management of patients who have undergone resection arthroplasty of the hip and who are suspected of having an infected pseudoarticular space is discussed.",
keywords = "Resection Arthroplasty of Hip Joint, Sepsis, Ultrasonography",
author = "K. F{\"o}ldes and P. B{\'a}lint and G. B{\'a}lint and Buchanan, {W. Watson}",
year = "1995",
month = "5",
doi = "10.1007/BF02208348",
language = "English",
volume = "14",
pages = "327--329",
journal = "Clinical Rheumatology",
issn = "0770-3198",
publisher = "Springer London",
number = "3",

}

TY - JOUR

T1 - Ultrasound-guided aspiration in suspected sepsis of resection arthroplasty of the hip joint

AU - Földes, K.

AU - Bálint, P.

AU - Bálint, G.

AU - Buchanan, W. Watson

PY - 1995/5

Y1 - 1995/5

N2 - The authors described 17 patients who had had resection arthroplasty of the hip and who were suspected of having an infection. The resection arthroplasties had been performed for previous infection. All the patients were studied by ultrasonography to detect effusion in the pseudoarticular space. Thirteen of the 17 patients were found to have an effusion by ultrasonography. Fluid was obtained in 9 of the 13 patients by ultrasonographic-guided aspiration. The mean aspirated volume was 3 ml (range 1-25 ml). Five of the 9 aspirates proved to be septic. The echopattern in all but one of those five with sepsis was nonechofree. Of four other patients in whom it was not possible to aspirate fluid lavage of the pseudoarticular space one yielded a positive culture. The role of ultrasonography in the diagnosis and management of patients who have undergone resection arthroplasty of the hip and who are suspected of having an infected pseudoarticular space is discussed.

AB - The authors described 17 patients who had had resection arthroplasty of the hip and who were suspected of having an infection. The resection arthroplasties had been performed for previous infection. All the patients were studied by ultrasonography to detect effusion in the pseudoarticular space. Thirteen of the 17 patients were found to have an effusion by ultrasonography. Fluid was obtained in 9 of the 13 patients by ultrasonographic-guided aspiration. The mean aspirated volume was 3 ml (range 1-25 ml). Five of the 9 aspirates proved to be septic. The echopattern in all but one of those five with sepsis was nonechofree. Of four other patients in whom it was not possible to aspirate fluid lavage of the pseudoarticular space one yielded a positive culture. The role of ultrasonography in the diagnosis and management of patients who have undergone resection arthroplasty of the hip and who are suspected of having an infected pseudoarticular space is discussed.

KW - Resection Arthroplasty of Hip Joint

KW - Sepsis

KW - Ultrasonography

UR - http://www.scopus.com/inward/record.url?scp=0029006637&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029006637&partnerID=8YFLogxK

U2 - 10.1007/BF02208348

DO - 10.1007/BF02208348

M3 - Article

VL - 14

SP - 327

EP - 329

JO - Clinical Rheumatology

JF - Clinical Rheumatology

SN - 0770-3198

IS - 3

ER -