Three-dimensional data processing for time resolved gamma-ray spectrometry

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method.

Original languageEnglish
Pages (from-to)213-219
Number of pages7
JournalJournal of Radioanalytical and Nuclear Chemistry
Volume265
Issue number2
DOIs
Publication statusPublished - Aug 2005

Fingerprint

Gamma Spectrometry
Gamma Rays
Curve fitting
Gamma rays
Spectrometry

ASJC Scopus subject areas

  • Analytical Chemistry
  • Inorganic Chemistry
  • Nuclear Energy and Engineering

Cite this

Three-dimensional data processing for time resolved gamma-ray spectrometry. / Szentmiklósi, L.; Révay, Zs; Molnár, G.

In: Journal of Radioanalytical and Nuclear Chemistry, Vol. 265, No. 2, 08.2005, p. 213-219.

Research output: Contribution to journalArticle

@article{c328d6ff5e8143c1963071ed90b4955f,
title = "Three-dimensional data processing for time resolved gamma-ray spectrometry",
abstract = "A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method.",
author = "L. Szentmikl{\'o}si and Zs R{\'e}vay and G. Moln{\'a}r",
year = "2005",
month = "8",
doi = "10.1007/s10967-005-0811-9",
language = "English",
volume = "265",
pages = "213--219",
journal = "Journal of Radioanalytical and Nuclear Chemistry",
issn = "0022-4081",
publisher = "Elsevier BV",
number = "2",

}

TY - JOUR

T1 - Three-dimensional data processing for time resolved gamma-ray spectrometry

AU - Szentmiklósi, L.

AU - Révay, Zs

AU - Molnár, G.

PY - 2005/8

Y1 - 2005/8

N2 - A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method.

AB - A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method.

UR - http://www.scopus.com/inward/record.url?scp=22544436369&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=22544436369&partnerID=8YFLogxK

U2 - 10.1007/s10967-005-0811-9

DO - 10.1007/s10967-005-0811-9

M3 - Article

AN - SCOPUS:22544436369

VL - 265

SP - 213

EP - 219

JO - Journal of Radioanalytical and Nuclear Chemistry

JF - Journal of Radioanalytical and Nuclear Chemistry

SN - 0022-4081

IS - 2

ER -