The interaction of thrombin and heparin. Heat inactivation kinetics

R. Machovich, György Blaskó, Péter Arányi

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Kinetic analysis of heat inactivation of thrombin in the presence of varying concentrations of heparin suggests that two forms of thrombin exist with respect to heparin sensitivity. One of them is inactivated by heat easily and cannot be stabilized with heparin. The other one interacts with heparin and is protected against heat inactivation at 54°C.

Original languageEnglish
Pages (from-to)253-260
Number of pages8
JournalThrombosis Research
Volume7
Issue number2
DOIs
Publication statusPublished - 1975

Fingerprint

Thrombin
Heparin
Hot Temperature

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Hematology

Cite this

The interaction of thrombin and heparin. Heat inactivation kinetics. / Machovich, R.; Blaskó, György; Arányi, Péter.

In: Thrombosis Research, Vol. 7, No. 2, 1975, p. 253-260.

Research output: Contribution to journalArticle

Machovich, R. ; Blaskó, György ; Arányi, Péter. / The interaction of thrombin and heparin. Heat inactivation kinetics. In: Thrombosis Research. 1975 ; Vol. 7, No. 2. pp. 253-260.
@article{c609936c5c4b445ab8e364c59fc00c1b,
title = "The interaction of thrombin and heparin. Heat inactivation kinetics",
abstract = "Kinetic analysis of heat inactivation of thrombin in the presence of varying concentrations of heparin suggests that two forms of thrombin exist with respect to heparin sensitivity. One of them is inactivated by heat easily and cannot be stabilized with heparin. The other one interacts with heparin and is protected against heat inactivation at 54°C.",
author = "R. Machovich and Gy{\"o}rgy Blask{\'o} and P{\'e}ter Ar{\'a}nyi",
year = "1975",
doi = "10.1016/0049-3848(75)90184-X",
language = "English",
volume = "7",
pages = "253--260",
journal = "Thrombosis Research",
issn = "0049-3848",
publisher = "Elsevier Limited",
number = "2",

}

TY - JOUR

T1 - The interaction of thrombin and heparin. Heat inactivation kinetics

AU - Machovich, R.

AU - Blaskó, György

AU - Arányi, Péter

PY - 1975

Y1 - 1975

N2 - Kinetic analysis of heat inactivation of thrombin in the presence of varying concentrations of heparin suggests that two forms of thrombin exist with respect to heparin sensitivity. One of them is inactivated by heat easily and cannot be stabilized with heparin. The other one interacts with heparin and is protected against heat inactivation at 54°C.

AB - Kinetic analysis of heat inactivation of thrombin in the presence of varying concentrations of heparin suggests that two forms of thrombin exist with respect to heparin sensitivity. One of them is inactivated by heat easily and cannot be stabilized with heparin. The other one interacts with heparin and is protected against heat inactivation at 54°C.

UR - http://www.scopus.com/inward/record.url?scp=0016774662&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016774662&partnerID=8YFLogxK

U2 - 10.1016/0049-3848(75)90184-X

DO - 10.1016/0049-3848(75)90184-X

M3 - Article

C2 - 1162646

AN - SCOPUS:0016774662

VL - 7

SP - 253

EP - 260

JO - Thrombosis Research

JF - Thrombosis Research

SN - 0049-3848

IS - 2

ER -