The external demagnetizing factor and the static characteristic loop

J. Takács, Gy Kovács, L. K. Varga

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

In this paper a proposal is put forward for the calculation of the shearing factor N S linked to the well known, demagnetization coefficient N D, from the data of a sheared saturation loop, obtained by a non-toroidal, open circuit hysteresis measurement. Following that, the paper illustrates the way to recover the real static loop data from an open circuit, measured data. The proposal is based on the hyperbolic model. The proposed method was illustrated on the tests carried out on two closed and open toroidal samples, mimicking the demagnetization effect of the open circuit VSM measurement, made of NO Fe-Si electrical steel sheets. These test results, presented here, agree very well with the calculated results, based on the hyperbolic modeling.

Original languageEnglish
Pages (from-to)2434-2437
Number of pages4
JournalPhysica B: Condensed Matter
Volume407
Issue number13
DOIs
Publication statusPublished - Jul 1 2012

Fingerprint

static characteristics
Demagnetization
demagnetization
proposals
Networks (circuits)
Steel sheet
shearing
Shearing
Hysteresis
hysteresis
steels
saturation
coefficients

Keywords

  • Demagnetization
  • Magnetism
  • Modeling

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

The external demagnetizing factor and the static characteristic loop. / Takács, J.; Kovács, Gy; Varga, L. K.

In: Physica B: Condensed Matter, Vol. 407, No. 13, 01.07.2012, p. 2434-2437.

Research output: Contribution to journalArticle

Takács, J. ; Kovács, Gy ; Varga, L. K. / The external demagnetizing factor and the static characteristic loop. In: Physica B: Condensed Matter. 2012 ; Vol. 407, No. 13. pp. 2434-2437.
@article{527d062f2e5b4580b3368b48a044cbaf,
title = "The external demagnetizing factor and the static characteristic loop",
abstract = "In this paper a proposal is put forward for the calculation of the shearing factor N S linked to the well known, demagnetization coefficient N D, from the data of a sheared saturation loop, obtained by a non-toroidal, open circuit hysteresis measurement. Following that, the paper illustrates the way to recover the real static loop data from an open circuit, measured data. The proposal is based on the hyperbolic model. The proposed method was illustrated on the tests carried out on two closed and open toroidal samples, mimicking the demagnetization effect of the open circuit VSM measurement, made of NO Fe-Si electrical steel sheets. These test results, presented here, agree very well with the calculated results, based on the hyperbolic modeling.",
keywords = "Demagnetization, Magnetism, Modeling",
author = "J. Tak{\'a}cs and Gy Kov{\'a}cs and Varga, {L. K.}",
year = "2012",
month = "7",
day = "1",
doi = "10.1016/j.physb.2012.03.041",
language = "English",
volume = "407",
pages = "2434--2437",
journal = "Physica B: Condensed Matter",
issn = "0921-4526",
publisher = "Elsevier",
number = "13",

}

TY - JOUR

T1 - The external demagnetizing factor and the static characteristic loop

AU - Takács, J.

AU - Kovács, Gy

AU - Varga, L. K.

PY - 2012/7/1

Y1 - 2012/7/1

N2 - In this paper a proposal is put forward for the calculation of the shearing factor N S linked to the well known, demagnetization coefficient N D, from the data of a sheared saturation loop, obtained by a non-toroidal, open circuit hysteresis measurement. Following that, the paper illustrates the way to recover the real static loop data from an open circuit, measured data. The proposal is based on the hyperbolic model. The proposed method was illustrated on the tests carried out on two closed and open toroidal samples, mimicking the demagnetization effect of the open circuit VSM measurement, made of NO Fe-Si electrical steel sheets. These test results, presented here, agree very well with the calculated results, based on the hyperbolic modeling.

AB - In this paper a proposal is put forward for the calculation of the shearing factor N S linked to the well known, demagnetization coefficient N D, from the data of a sheared saturation loop, obtained by a non-toroidal, open circuit hysteresis measurement. Following that, the paper illustrates the way to recover the real static loop data from an open circuit, measured data. The proposal is based on the hyperbolic model. The proposed method was illustrated on the tests carried out on two closed and open toroidal samples, mimicking the demagnetization effect of the open circuit VSM measurement, made of NO Fe-Si electrical steel sheets. These test results, presented here, agree very well with the calculated results, based on the hyperbolic modeling.

KW - Demagnetization

KW - Magnetism

KW - Modeling

UR - http://www.scopus.com/inward/record.url?scp=84860357797&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84860357797&partnerID=8YFLogxK

U2 - 10.1016/j.physb.2012.03.041

DO - 10.1016/j.physb.2012.03.041