Temporal contrast of high intensity laser systems above 1011 with double CPA technique

M. P. Kalashnikov, K. Osvay, G. Priebe, L. Ehrentraut, S. Steinke, W. Sandner

Research output: Chapter in Book/Report/Conference proceedingConference contribution

14 Citations (Scopus)

Abstract

Using a combination of the Negative-Positive, the Double Chirped Pulse Amplification techniques with nonlinear XPW temporal filtering in the laser front end allows substantial suppression the ASE level pushing the temporal contrast of amplified 100 TW pulses at 10 Hz operation above 1011.

Original languageEnglish
Title of host publicationAIP Conference Proceedings
Pages108-111
Number of pages4
Volume1462
DOIs
Publication statusPublished - 2012
EventLight at Extreme Intensities 2011, LEI 2011 - Szeged, Hungary
Duration: Nov 14 2011Nov 18 2011

Other

OtherLight at Extreme Intensities 2011, LEI 2011
CountryHungary
CitySzeged
Period11/14/1111/18/11

Fingerprint

high power lasers
aeroservoelasticity
pushing
pulses
retarding
lasers

Keywords

  • High contrast laser pulse
  • High intensity lasers

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Kalashnikov, M. P., Osvay, K., Priebe, G., Ehrentraut, L., Steinke, S., & Sandner, W. (2012). Temporal contrast of high intensity laser systems above 1011 with double CPA technique. In AIP Conference Proceedings (Vol. 1462, pp. 108-111) https://doi.org/10.1063/1.4736771

Temporal contrast of high intensity laser systems above 1011 with double CPA technique. / Kalashnikov, M. P.; Osvay, K.; Priebe, G.; Ehrentraut, L.; Steinke, S.; Sandner, W.

AIP Conference Proceedings. Vol. 1462 2012. p. 108-111.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kalashnikov, MP, Osvay, K, Priebe, G, Ehrentraut, L, Steinke, S & Sandner, W 2012, Temporal contrast of high intensity laser systems above 1011 with double CPA technique. in AIP Conference Proceedings. vol. 1462, pp. 108-111, Light at Extreme Intensities 2011, LEI 2011, Szeged, Hungary, 11/14/11. https://doi.org/10.1063/1.4736771
Kalashnikov MP, Osvay K, Priebe G, Ehrentraut L, Steinke S, Sandner W. Temporal contrast of high intensity laser systems above 1011 with double CPA technique. In AIP Conference Proceedings. Vol. 1462. 2012. p. 108-111 https://doi.org/10.1063/1.4736771
Kalashnikov, M. P. ; Osvay, K. ; Priebe, G. ; Ehrentraut, L. ; Steinke, S. ; Sandner, W. / Temporal contrast of high intensity laser systems above 1011 with double CPA technique. AIP Conference Proceedings. Vol. 1462 2012. pp. 108-111
@inproceedings{33a577353c4641558873a4ff417d0769,
title = "Temporal contrast of high intensity laser systems above 1011 with double CPA technique",
abstract = "Using a combination of the Negative-Positive, the Double Chirped Pulse Amplification techniques with nonlinear XPW temporal filtering in the laser front end allows substantial suppression the ASE level pushing the temporal contrast of amplified 100 TW pulses at 10 Hz operation above 1011.",
keywords = "High contrast laser pulse, High intensity lasers",
author = "Kalashnikov, {M. P.} and K. Osvay and G. Priebe and L. Ehrentraut and S. Steinke and W. Sandner",
year = "2012",
doi = "10.1063/1.4736771",
language = "English",
isbn = "9780735410664",
volume = "1462",
pages = "108--111",
booktitle = "AIP Conference Proceedings",

}

TY - GEN

T1 - Temporal contrast of high intensity laser systems above 1011 with double CPA technique

AU - Kalashnikov, M. P.

AU - Osvay, K.

AU - Priebe, G.

AU - Ehrentraut, L.

AU - Steinke, S.

AU - Sandner, W.

PY - 2012

Y1 - 2012

N2 - Using a combination of the Negative-Positive, the Double Chirped Pulse Amplification techniques with nonlinear XPW temporal filtering in the laser front end allows substantial suppression the ASE level pushing the temporal contrast of amplified 100 TW pulses at 10 Hz operation above 1011.

AB - Using a combination of the Negative-Positive, the Double Chirped Pulse Amplification techniques with nonlinear XPW temporal filtering in the laser front end allows substantial suppression the ASE level pushing the temporal contrast of amplified 100 TW pulses at 10 Hz operation above 1011.

KW - High contrast laser pulse

KW - High intensity lasers

UR - http://www.scopus.com/inward/record.url?scp=84873122613&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84873122613&partnerID=8YFLogxK

U2 - 10.1063/1.4736771

DO - 10.1063/1.4736771

M3 - Conference contribution

SN - 9780735410664

VL - 1462

SP - 108

EP - 111

BT - AIP Conference Proceedings

ER -