TCTU - EIN PROGRAMM FUR DAS IMAC-SYSTEM ZUR DURCHFUHRUNG DES 99mTc THYROID UPTAKE TESTS IN DER SCHILDDRUSENDIAGNOSTIK

Translated title of the contribution: TCTU - a program for the IMAC processing system for 99mTc thyroid uptake test in thyroid diagnostics

J. Mahlstedt, J. Csirik

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

A program for the IMAC processing system is presented for performing TcTU with gamma camera and computer during routine thyroid diagnostics. Besides data calculation, the program includes all data acquisition, data handling and documentation. It can be run in 2- or 3-disk versions and uses large parts of the standard program being fully compatible with the latter. For data acquisition there are no restrictions concerning acquisition mode (word matrix or byte matrix, acquisition time, matrix size and zoom). With minor modification the program can be used for 123I too. The detailed program description is available from the authors upon request.

Original languageGerman
Pages (from-to)37-40
Number of pages4
JournalNUC Compact
Volume12
Issue number1
Publication statusPublished - 1981

Fingerprint

Gamma Cameras
Program Development
Documentation
Thyroid Gland
imidazoleacetic acid

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

TCTU - EIN PROGRAMM FUR DAS IMAC-SYSTEM ZUR DURCHFUHRUNG DES 99mTc THYROID UPTAKE TESTS IN DER SCHILDDRUSENDIAGNOSTIK. / Mahlstedt, J.; Csirik, J.

In: NUC Compact, Vol. 12, No. 1, 1981, p. 37-40.

Research output: Contribution to journalArticle

@article{5dbec3e8f6774f0890ea130db5e94b6d,
title = "TCTU - EIN PROGRAMM FUR DAS IMAC-SYSTEM ZUR DURCHFUHRUNG DES 99mTc THYROID UPTAKE TESTS IN DER SCHILDDRUSENDIAGNOSTIK",
abstract = "A program for the IMAC processing system is presented for performing TcTU with gamma camera and computer during routine thyroid diagnostics. Besides data calculation, the program includes all data acquisition, data handling and documentation. It can be run in 2- or 3-disk versions and uses large parts of the standard program being fully compatible with the latter. For data acquisition there are no restrictions concerning acquisition mode (word matrix or byte matrix, acquisition time, matrix size and zoom). With minor modification the program can be used for 123I too. The detailed program description is available from the authors upon request.",
author = "J. Mahlstedt and J. Csirik",
year = "1981",
language = "German",
volume = "12",
pages = "37--40",
journal = "NUC Compact",
issn = "0344-3752",
number = "1",

}

TY - JOUR

T1 - TCTU - EIN PROGRAMM FUR DAS IMAC-SYSTEM ZUR DURCHFUHRUNG DES 99mTc THYROID UPTAKE TESTS IN DER SCHILDDRUSENDIAGNOSTIK

AU - Mahlstedt, J.

AU - Csirik, J.

PY - 1981

Y1 - 1981

N2 - A program for the IMAC processing system is presented for performing TcTU with gamma camera and computer during routine thyroid diagnostics. Besides data calculation, the program includes all data acquisition, data handling and documentation. It can be run in 2- or 3-disk versions and uses large parts of the standard program being fully compatible with the latter. For data acquisition there are no restrictions concerning acquisition mode (word matrix or byte matrix, acquisition time, matrix size and zoom). With minor modification the program can be used for 123I too. The detailed program description is available from the authors upon request.

AB - A program for the IMAC processing system is presented for performing TcTU with gamma camera and computer during routine thyroid diagnostics. Besides data calculation, the program includes all data acquisition, data handling and documentation. It can be run in 2- or 3-disk versions and uses large parts of the standard program being fully compatible with the latter. For data acquisition there are no restrictions concerning acquisition mode (word matrix or byte matrix, acquisition time, matrix size and zoom). With minor modification the program can be used for 123I too. The detailed program description is available from the authors upon request.

UR - http://www.scopus.com/inward/record.url?scp=0019457208&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019457208&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0019457208

VL - 12

SP - 37

EP - 40

JO - NUC Compact

JF - NUC Compact

SN - 0344-3752

IS - 1

ER -