Study on the beam transport from the Bio-Nano ECRIS

T. Uchida, H. Minezaki, K. Oshima, R. Racz, M. Muramatsu, T. Asaji, A. Kitagawa, Y. Kato, S. Biri, Y. Yoshida

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The beam transport of N+ ion and C60+ ion in the Bio-Nano ECRIS with min-B configuration was investigated based on the ion beam profiles. The N+ beam could be focused under the low-beam current conditions. Also the C60+ beam could be focused in spite of the large space-charge effect which will lead the divergence of the beam. We confirmed that our beam transport system works well even for the C 60+ ion beam. We estimated the highest C60 + beam current with the focused beam profile by comparing the N + ion beam.

Original languageEnglish
Article number02B713
JournalReview of Scientific Instruments
Volume83
Issue number2
DOIs
Publication statusPublished - 2012

Fingerprint

Ion beams
Ions
ion beams
beam currents
Electric space charge
Ion Transport
profiles
space charge
divergence
ions
configurations

ASJC Scopus subject areas

  • Instrumentation
  • Medicine(all)

Cite this

Uchida, T., Minezaki, H., Oshima, K., Racz, R., Muramatsu, M., Asaji, T., ... Yoshida, Y. (2012). Study on the beam transport from the Bio-Nano ECRIS. Review of Scientific Instruments, 83(2), [02B713]. https://doi.org/10.1063/1.3670597

Study on the beam transport from the Bio-Nano ECRIS. / Uchida, T.; Minezaki, H.; Oshima, K.; Racz, R.; Muramatsu, M.; Asaji, T.; Kitagawa, A.; Kato, Y.; Biri, S.; Yoshida, Y.

In: Review of Scientific Instruments, Vol. 83, No. 2, 02B713, 2012.

Research output: Contribution to journalArticle

Uchida, T, Minezaki, H, Oshima, K, Racz, R, Muramatsu, M, Asaji, T, Kitagawa, A, Kato, Y, Biri, S & Yoshida, Y 2012, 'Study on the beam transport from the Bio-Nano ECRIS', Review of Scientific Instruments, vol. 83, no. 2, 02B713. https://doi.org/10.1063/1.3670597
Uchida T, Minezaki H, Oshima K, Racz R, Muramatsu M, Asaji T et al. Study on the beam transport from the Bio-Nano ECRIS. Review of Scientific Instruments. 2012;83(2). 02B713. https://doi.org/10.1063/1.3670597
Uchida, T. ; Minezaki, H. ; Oshima, K. ; Racz, R. ; Muramatsu, M. ; Asaji, T. ; Kitagawa, A. ; Kato, Y. ; Biri, S. ; Yoshida, Y. / Study on the beam transport from the Bio-Nano ECRIS. In: Review of Scientific Instruments. 2012 ; Vol. 83, No. 2.
@article{b716939fa9de424d8f73a89bccc9ea2e,
title = "Study on the beam transport from the Bio-Nano ECRIS",
abstract = "The beam transport of N+ ion and C60+ ion in the Bio-Nano ECRIS with min-B configuration was investigated based on the ion beam profiles. The N+ beam could be focused under the low-beam current conditions. Also the C60+ beam could be focused in spite of the large space-charge effect which will lead the divergence of the beam. We confirmed that our beam transport system works well even for the C 60+ ion beam. We estimated the highest C60 + beam current with the focused beam profile by comparing the N + ion beam.",
author = "T. Uchida and H. Minezaki and K. Oshima and R. Racz and M. Muramatsu and T. Asaji and A. Kitagawa and Y. Kato and S. Biri and Y. Yoshida",
year = "2012",
doi = "10.1063/1.3670597",
language = "English",
volume = "83",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "2",

}

TY - JOUR

T1 - Study on the beam transport from the Bio-Nano ECRIS

AU - Uchida, T.

AU - Minezaki, H.

AU - Oshima, K.

AU - Racz, R.

AU - Muramatsu, M.

AU - Asaji, T.

AU - Kitagawa, A.

AU - Kato, Y.

AU - Biri, S.

AU - Yoshida, Y.

PY - 2012

Y1 - 2012

N2 - The beam transport of N+ ion and C60+ ion in the Bio-Nano ECRIS with min-B configuration was investigated based on the ion beam profiles. The N+ beam could be focused under the low-beam current conditions. Also the C60+ beam could be focused in spite of the large space-charge effect which will lead the divergence of the beam. We confirmed that our beam transport system works well even for the C 60+ ion beam. We estimated the highest C60 + beam current with the focused beam profile by comparing the N + ion beam.

AB - The beam transport of N+ ion and C60+ ion in the Bio-Nano ECRIS with min-B configuration was investigated based on the ion beam profiles. The N+ beam could be focused under the low-beam current conditions. Also the C60+ beam could be focused in spite of the large space-charge effect which will lead the divergence of the beam. We confirmed that our beam transport system works well even for the C 60+ ion beam. We estimated the highest C60 + beam current with the focused beam profile by comparing the N + ion beam.

UR - http://www.scopus.com/inward/record.url?scp=84857850547&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857850547&partnerID=8YFLogxK

U2 - 10.1063/1.3670597

DO - 10.1063/1.3670597

M3 - Article

VL - 83

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 2

M1 - 02B713

ER -