Statistical determination of the proper sample size in multicomponent separations

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The Fourier analysis of multicomponent chromatograms is applied to chromatograms of diesel fuels. The concentration of the injected sample was varied over several orders of magnitude. The number of components, the average peak width, as well as the retention pattern were determined for all sample concentrations. The lower edge of the practical sample size is limited by the baseline noise, whereas the upper limit is set by column overload. By means of statistical analysis, those two boundaries were isolated and a method is proposed to determine the useful sample size for the analysis of any multicomponent mixture. Copyright (C) 1999 Elsevier Science B.V.

Original languageEnglish
Pages (from-to)129-139
Number of pages11
JournalJournal of Chromatography A
Volume839
Issue number1-2
DOIs
Publication statusPublished - Apr 16 1999

Fingerprint

Fourier analysis
Diesel fuels
Sample Size
Statistical methods
Gasoline
Fourier Analysis
Noise

Keywords

  • Diesel fuel
  • Fourier analysis
  • Sample size

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Statistical determination of the proper sample size in multicomponent separations. / Felinger, A.; Vigh, Ervin; Gelencsér, A.

In: Journal of Chromatography A, Vol. 839, No. 1-2, 16.04.1999, p. 129-139.

Research output: Contribution to journalArticle

@article{5d7fa25d483f45de80d70901abf74392,
title = "Statistical determination of the proper sample size in multicomponent separations",
abstract = "The Fourier analysis of multicomponent chromatograms is applied to chromatograms of diesel fuels. The concentration of the injected sample was varied over several orders of magnitude. The number of components, the average peak width, as well as the retention pattern were determined for all sample concentrations. The lower edge of the practical sample size is limited by the baseline noise, whereas the upper limit is set by column overload. By means of statistical analysis, those two boundaries were isolated and a method is proposed to determine the useful sample size for the analysis of any multicomponent mixture. Copyright (C) 1999 Elsevier Science B.V.",
keywords = "Diesel fuel, Fourier analysis, Sample size",
author = "A. Felinger and Ervin Vigh and A. Gelencs{\'e}r",
year = "1999",
month = "4",
day = "16",
doi = "10.1016/S0021-9673(99)00068-0",
language = "English",
volume = "839",
pages = "129--139",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - Statistical determination of the proper sample size in multicomponent separations

AU - Felinger, A.

AU - Vigh, Ervin

AU - Gelencsér, A.

PY - 1999/4/16

Y1 - 1999/4/16

N2 - The Fourier analysis of multicomponent chromatograms is applied to chromatograms of diesel fuels. The concentration of the injected sample was varied over several orders of magnitude. The number of components, the average peak width, as well as the retention pattern were determined for all sample concentrations. The lower edge of the practical sample size is limited by the baseline noise, whereas the upper limit is set by column overload. By means of statistical analysis, those two boundaries were isolated and a method is proposed to determine the useful sample size for the analysis of any multicomponent mixture. Copyright (C) 1999 Elsevier Science B.V.

AB - The Fourier analysis of multicomponent chromatograms is applied to chromatograms of diesel fuels. The concentration of the injected sample was varied over several orders of magnitude. The number of components, the average peak width, as well as the retention pattern were determined for all sample concentrations. The lower edge of the practical sample size is limited by the baseline noise, whereas the upper limit is set by column overload. By means of statistical analysis, those two boundaries were isolated and a method is proposed to determine the useful sample size for the analysis of any multicomponent mixture. Copyright (C) 1999 Elsevier Science B.V.

KW - Diesel fuel

KW - Fourier analysis

KW - Sample size

UR - http://www.scopus.com/inward/record.url?scp=0032916826&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032916826&partnerID=8YFLogxK

U2 - 10.1016/S0021-9673(99)00068-0

DO - 10.1016/S0021-9673(99)00068-0

M3 - Article

AN - SCOPUS:0032916826

VL - 839

SP - 129

EP - 139

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

IS - 1-2

ER -