Station 16.3

A high-resolution single-crystal diffraction facility at the SRS, Daresbury

S. P. Collins, R. J. Cernik, B. Fell, C. C. Tang, N. W. Harris, M. C. Miller, G. Oszlányi

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

SRS station 16.3 is now a fully scheduled user facility for high-resolution and high-energy single-crystal X-ray diffraction. It is based on a large three-axis diffractometer, designed and constructed at Daresbury for a wide range of physics and materials science applications. Served by wiggler 16 (a 6 T superconducting wavelength-shifter), the station has access to a broad spectrum of photon energies, extending to over 50 keV, and is designed for simple polarization-state tuning by motorized height adjustment of all optical components. This paper outlines the key design features and some of the science projects carried out during the first year of operation.

Original languageEnglish
Pages (from-to)1263-1269
Number of pages7
JournalJournal of Synchrotron Radiation
Volume5
Issue number5
Publication statusPublished - Sep 1 1998

Fingerprint

Diffractometers
Materials science
Photons
Physics
Tuning
stations
Diffraction
Single crystals
Polarization
X ray diffraction
Wavelength
high resolution
single crystals
materials science
diffractometers
diffraction
adjusting
tuning
physics
energy

Keywords

  • Critical exponents
  • Diffraction
  • Diffractometers
  • Magnetic diffraction
  • SRS station 16.3

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)
  • Instrumentation
  • Atomic and Molecular Physics, and Optics
  • Radiation

Cite this

Collins, S. P., Cernik, R. J., Fell, B., Tang, C. C., Harris, N. W., Miller, M. C., & Oszlányi, G. (1998). Station 16.3: A high-resolution single-crystal diffraction facility at the SRS, Daresbury. Journal of Synchrotron Radiation, 5(5), 1263-1269.

Station 16.3 : A high-resolution single-crystal diffraction facility at the SRS, Daresbury. / Collins, S. P.; Cernik, R. J.; Fell, B.; Tang, C. C.; Harris, N. W.; Miller, M. C.; Oszlányi, G.

In: Journal of Synchrotron Radiation, Vol. 5, No. 5, 01.09.1998, p. 1263-1269.

Research output: Contribution to journalArticle

Collins, SP, Cernik, RJ, Fell, B, Tang, CC, Harris, NW, Miller, MC & Oszlányi, G 1998, 'Station 16.3: A high-resolution single-crystal diffraction facility at the SRS, Daresbury', Journal of Synchrotron Radiation, vol. 5, no. 5, pp. 1263-1269.
Collins SP, Cernik RJ, Fell B, Tang CC, Harris NW, Miller MC et al. Station 16.3: A high-resolution single-crystal diffraction facility at the SRS, Daresbury. Journal of Synchrotron Radiation. 1998 Sep 1;5(5):1263-1269.
Collins, S. P. ; Cernik, R. J. ; Fell, B. ; Tang, C. C. ; Harris, N. W. ; Miller, M. C. ; Oszlányi, G. / Station 16.3 : A high-resolution single-crystal diffraction facility at the SRS, Daresbury. In: Journal of Synchrotron Radiation. 1998 ; Vol. 5, No. 5. pp. 1263-1269.
@article{04e3edb1a3c8408299fd479fd1579bfa,
title = "Station 16.3: A high-resolution single-crystal diffraction facility at the SRS, Daresbury",
abstract = "SRS station 16.3 is now a fully scheduled user facility for high-resolution and high-energy single-crystal X-ray diffraction. It is based on a large three-axis diffractometer, designed and constructed at Daresbury for a wide range of physics and materials science applications. Served by wiggler 16 (a 6 T superconducting wavelength-shifter), the station has access to a broad spectrum of photon energies, extending to over 50 keV, and is designed for simple polarization-state tuning by motorized height adjustment of all optical components. This paper outlines the key design features and some of the science projects carried out during the first year of operation.",
keywords = "Critical exponents, Diffraction, Diffractometers, Magnetic diffraction, SRS station 16.3",
author = "Collins, {S. P.} and Cernik, {R. J.} and B. Fell and Tang, {C. C.} and Harris, {N. W.} and Miller, {M. C.} and G. Oszl{\'a}nyi",
year = "1998",
month = "9",
day = "1",
language = "English",
volume = "5",
pages = "1263--1269",
journal = "Journal of Synchrotron Radiation",
issn = "0909-0495",
publisher = "International Union of Crystallography",
number = "5",

}

TY - JOUR

T1 - Station 16.3

T2 - A high-resolution single-crystal diffraction facility at the SRS, Daresbury

AU - Collins, S. P.

AU - Cernik, R. J.

AU - Fell, B.

AU - Tang, C. C.

AU - Harris, N. W.

AU - Miller, M. C.

AU - Oszlányi, G.

PY - 1998/9/1

Y1 - 1998/9/1

N2 - SRS station 16.3 is now a fully scheduled user facility for high-resolution and high-energy single-crystal X-ray diffraction. It is based on a large three-axis diffractometer, designed and constructed at Daresbury for a wide range of physics and materials science applications. Served by wiggler 16 (a 6 T superconducting wavelength-shifter), the station has access to a broad spectrum of photon energies, extending to over 50 keV, and is designed for simple polarization-state tuning by motorized height adjustment of all optical components. This paper outlines the key design features and some of the science projects carried out during the first year of operation.

AB - SRS station 16.3 is now a fully scheduled user facility for high-resolution and high-energy single-crystal X-ray diffraction. It is based on a large three-axis diffractometer, designed and constructed at Daresbury for a wide range of physics and materials science applications. Served by wiggler 16 (a 6 T superconducting wavelength-shifter), the station has access to a broad spectrum of photon energies, extending to over 50 keV, and is designed for simple polarization-state tuning by motorized height adjustment of all optical components. This paper outlines the key design features and some of the science projects carried out during the first year of operation.

KW - Critical exponents

KW - Diffraction

KW - Diffractometers

KW - Magnetic diffraction

KW - SRS station 16.3

UR - http://www.scopus.com/inward/record.url?scp=0032222059&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032222059&partnerID=8YFLogxK

M3 - Article

VL - 5

SP - 1263

EP - 1269

JO - Journal of Synchrotron Radiation

JF - Journal of Synchrotron Radiation

SN - 0909-0495

IS - 5

ER -