Calcaneus fractures with joint crunches need surgical treatment. This treatment can be closed reposition and overstitching, or open reposition with osteosynthesis using an H plate. There is also a minimal invasive technique, whereby the fracture is reduced with a distraction device in a closed manner and stabilized with three supporting screws. This method became widespread with Zadravecz's endeavors and has become the most popular and most frequent way of stabilization for calcaneus fractures in our institute. To further improve the Zadravecz's technique, we developed a new headless distraction screw. There are threads on both ends of the screw, which turn in the same direction. The size of the threads on the side of the screw head is greater in diameter and pitch compared to those on the other end, exerting and maintaining a distancing effect. The repositioning tool has undergone changes, as well. A desirable ligamentotaxis is achieved by a newly designed distraction-reposition apparatus. We currently use two half-arcs, on which three Kirschner wires can be used. For accurate repositioning, we rely upon the ligamentotaxis effect of the reposition tool, and the inner synergetic effect of the distraction screw. The technique described here was used in 56 patients (mean age 46 years; range 28 to 67 years) with calcaneus fractures. The patients were followed-up for a mean of 18.3 months (range 10 to 36 months) and were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) score for the ankle and hindfoot. The mean AOFAS score was 76.5 (range 54 to 98), and the mean pain score was 22 (range 22 to 32). The authors believe that this minimally invasive technique will arose even more interest among orthopedic surgeons.

Original languageEnglish
Pages (from-to)45-49
Number of pages5
JournalEklem Hastaliklari ve Cerrahisi
Volume19
Issue number1
Publication statusPublished - 2008

Fingerprint

Calcaneus
Ankle
Orthopedics
Foot
Bone Wires
Joints
Head
Pain
Equipment and Supplies
Therapeutics

Keywords

  • Bone screws
  • Calcaneus/injuries
  • Fracture fixation
  • Internal/methods
  • Manipulation, Orthopedic/methods

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery
  • Rehabilitation

Cite this

Stabilization of calcaneus fractures in a closed manner with a distraction screw. / Kádas, István; Szita, János; Zadravecz, György; Hangody, László; Dóczi, József.

In: Eklem Hastaliklari ve Cerrahisi, Vol. 19, No. 1, 2008, p. 45-49.

Research output: Contribution to journalArticle

Kádas, I, Szita, J, Zadravecz, G, Hangody, L & Dóczi, J 2008, 'Stabilization of calcaneus fractures in a closed manner with a distraction screw', Eklem Hastaliklari ve Cerrahisi, vol. 19, no. 1, pp. 45-49.
Kádas, István ; Szita, János ; Zadravecz, György ; Hangody, László ; Dóczi, József. / Stabilization of calcaneus fractures in a closed manner with a distraction screw. In: Eklem Hastaliklari ve Cerrahisi. 2008 ; Vol. 19, No. 1. pp. 45-49.
@article{ac534d43752241f9b7a16859ec5751e3,
title = "Stabilization of calcaneus fractures in a closed manner with a distraction screw",
abstract = "Calcaneus fractures with joint crunches need surgical treatment. This treatment can be closed reposition and overstitching, or open reposition with osteosynthesis using an H plate. There is also a minimal invasive technique, whereby the fracture is reduced with a distraction device in a closed manner and stabilized with three supporting screws. This method became widespread with Zadravecz's endeavors and has become the most popular and most frequent way of stabilization for calcaneus fractures in our institute. To further improve the Zadravecz's technique, we developed a new headless distraction screw. There are threads on both ends of the screw, which turn in the same direction. The size of the threads on the side of the screw head is greater in diameter and pitch compared to those on the other end, exerting and maintaining a distancing effect. The repositioning tool has undergone changes, as well. A desirable ligamentotaxis is achieved by a newly designed distraction-reposition apparatus. We currently use two half-arcs, on which three Kirschner wires can be used. For accurate repositioning, we rely upon the ligamentotaxis effect of the reposition tool, and the inner synergetic effect of the distraction screw. The technique described here was used in 56 patients (mean age 46 years; range 28 to 67 years) with calcaneus fractures. The patients were followed-up for a mean of 18.3 months (range 10 to 36 months) and were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) score for the ankle and hindfoot. The mean AOFAS score was 76.5 (range 54 to 98), and the mean pain score was 22 (range 22 to 32). The authors believe that this minimally invasive technique will arose even more interest among orthopedic surgeons.",
keywords = "Bone screws, Calcaneus/injuries, Fracture fixation, Internal/methods, Manipulation, Orthopedic/methods",
author = "Istv{\'a}n K{\'a}das and J{\'a}nos Szita and Gy{\"o}rgy Zadravecz and L{\'a}szl{\'o} Hangody and J{\'o}zsef D{\'o}czi",
year = "2008",
language = "English",
volume = "19",
pages = "45--49",
journal = "Eklem Hastaliklari ve Cerrahisi",
issn = "1305-8282",
publisher = "Turkish Joint Diseases Foundation",
number = "1",

}

TY - JOUR

T1 - Stabilization of calcaneus fractures in a closed manner with a distraction screw

AU - Kádas, István

AU - Szita, János

AU - Zadravecz, György

AU - Hangody, László

AU - Dóczi, József

PY - 2008

Y1 - 2008

N2 - Calcaneus fractures with joint crunches need surgical treatment. This treatment can be closed reposition and overstitching, or open reposition with osteosynthesis using an H plate. There is also a minimal invasive technique, whereby the fracture is reduced with a distraction device in a closed manner and stabilized with three supporting screws. This method became widespread with Zadravecz's endeavors and has become the most popular and most frequent way of stabilization for calcaneus fractures in our institute. To further improve the Zadravecz's technique, we developed a new headless distraction screw. There are threads on both ends of the screw, which turn in the same direction. The size of the threads on the side of the screw head is greater in diameter and pitch compared to those on the other end, exerting and maintaining a distancing effect. The repositioning tool has undergone changes, as well. A desirable ligamentotaxis is achieved by a newly designed distraction-reposition apparatus. We currently use two half-arcs, on which three Kirschner wires can be used. For accurate repositioning, we rely upon the ligamentotaxis effect of the reposition tool, and the inner synergetic effect of the distraction screw. The technique described here was used in 56 patients (mean age 46 years; range 28 to 67 years) with calcaneus fractures. The patients were followed-up for a mean of 18.3 months (range 10 to 36 months) and were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) score for the ankle and hindfoot. The mean AOFAS score was 76.5 (range 54 to 98), and the mean pain score was 22 (range 22 to 32). The authors believe that this minimally invasive technique will arose even more interest among orthopedic surgeons.

AB - Calcaneus fractures with joint crunches need surgical treatment. This treatment can be closed reposition and overstitching, or open reposition with osteosynthesis using an H plate. There is also a minimal invasive technique, whereby the fracture is reduced with a distraction device in a closed manner and stabilized with three supporting screws. This method became widespread with Zadravecz's endeavors and has become the most popular and most frequent way of stabilization for calcaneus fractures in our institute. To further improve the Zadravecz's technique, we developed a new headless distraction screw. There are threads on both ends of the screw, which turn in the same direction. The size of the threads on the side of the screw head is greater in diameter and pitch compared to those on the other end, exerting and maintaining a distancing effect. The repositioning tool has undergone changes, as well. A desirable ligamentotaxis is achieved by a newly designed distraction-reposition apparatus. We currently use two half-arcs, on which three Kirschner wires can be used. For accurate repositioning, we rely upon the ligamentotaxis effect of the reposition tool, and the inner synergetic effect of the distraction screw. The technique described here was used in 56 patients (mean age 46 years; range 28 to 67 years) with calcaneus fractures. The patients were followed-up for a mean of 18.3 months (range 10 to 36 months) and were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) score for the ankle and hindfoot. The mean AOFAS score was 76.5 (range 54 to 98), and the mean pain score was 22 (range 22 to 32). The authors believe that this minimally invasive technique will arose even more interest among orthopedic surgeons.

KW - Bone screws

KW - Calcaneus/injuries

KW - Fracture fixation

KW - Internal/methods

KW - Manipulation, Orthopedic/methods

UR - http://www.scopus.com/inward/record.url?scp=55149123346&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=55149123346&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:55149123346

VL - 19

SP - 45

EP - 49

JO - Eklem Hastaliklari ve Cerrahisi

JF - Eklem Hastaliklari ve Cerrahisi

SN - 1305-8282

IS - 1

ER -