Egyrétegú, tovafutó, felszívódó varratsorral készült anasztomózis a gastrointestinalis sebészetben.

Translated title of the contribution: Single layer continuous absorbable sutures for gastrointestinal anastomosis

A. Oláh, T. Belágyi, G. Neuberger, L. Hegedús

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Authors evaluated the safety of single layer continuous sutured anastomosis technique with two different types of absorbable sutures in 252 anastomoses performed on 178 patients. In the prospective, randomized study 5 oesophagus, 26 stomach, 117 small intestine, 32 colonic, 29 pancreatic and 43 biliary anastomoses were performed. In 136 cases poliglecaprone 25 (Monocryl), in 116 cases glycomer 631 (Biosyn) were used. All procedures were carried out by the same surgeon. Anastomosis related complication was detected in 7 cases (2.8%), some kind of anastomosis insufficiency--including minor leakage--in 5 cases (2.0%), but reoperation only in one case (0.4%) was required. There was no anastomosis related death. Authors overview the advantages of the technique, which is safe, cheap, easy to carry out, physiological and least harmful to the blood supply, so they recommend its use in the gastrointestinal surgery as a standard procedure.

Original languageHungarian
Pages (from-to)63-66
Number of pages4
JournalMagyar sebészet
Volume52
Issue number2
Publication statusPublished - 1999

Fingerprint

Sutures
Reoperation
Esophagus
Small Intestine
Stomach
Prospective Studies
Safety
glycolide E-caprolactone copolymer
Surgeons
glycomer 631

Cite this

Egyrétegú, tovafutó, felszívódó varratsorral készült anasztomózis a gastrointestinalis sebészetben. / Oláh, A.; Belágyi, T.; Neuberger, G.; Hegedús, L.

In: Magyar sebészet, Vol. 52, No. 2, 1999, p. 63-66.

Research output: Contribution to journalArticle

@article{3fad024bba70476fab5ed961aa0d150e,
title = "Egyr{\'e}teg{\'u}, tovafut{\'o}, felsz{\'i}v{\'o}d{\'o} varratsorral k{\'e}sz{\"u}lt anasztom{\'o}zis a gastrointestinalis seb{\'e}szetben.",
abstract = "Authors evaluated the safety of single layer continuous sutured anastomosis technique with two different types of absorbable sutures in 252 anastomoses performed on 178 patients. In the prospective, randomized study 5 oesophagus, 26 stomach, 117 small intestine, 32 colonic, 29 pancreatic and 43 biliary anastomoses were performed. In 136 cases poliglecaprone 25 (Monocryl), in 116 cases glycomer 631 (Biosyn) were used. All procedures were carried out by the same surgeon. Anastomosis related complication was detected in 7 cases (2.8{\%}), some kind of anastomosis insufficiency--including minor leakage--in 5 cases (2.0{\%}), but reoperation only in one case (0.4{\%}) was required. There was no anastomosis related death. Authors overview the advantages of the technique, which is safe, cheap, easy to carry out, physiological and least harmful to the blood supply, so they recommend its use in the gastrointestinal surgery as a standard procedure.",
author = "A. Ol{\'a}h and T. Bel{\'a}gyi and G. Neuberger and L. Heged{\'u}s",
year = "1999",
language = "Hungarian",
volume = "52",
pages = "63--66",
journal = "Magyar Sebeszet",
issn = "0025-0295",
publisher = "Ifjusagi Lapkiado Vallalat",
number = "2",

}

TY - JOUR

T1 - Egyrétegú, tovafutó, felszívódó varratsorral készült anasztomózis a gastrointestinalis sebészetben.

AU - Oláh, A.

AU - Belágyi, T.

AU - Neuberger, G.

AU - Hegedús, L.

PY - 1999

Y1 - 1999

N2 - Authors evaluated the safety of single layer continuous sutured anastomosis technique with two different types of absorbable sutures in 252 anastomoses performed on 178 patients. In the prospective, randomized study 5 oesophagus, 26 stomach, 117 small intestine, 32 colonic, 29 pancreatic and 43 biliary anastomoses were performed. In 136 cases poliglecaprone 25 (Monocryl), in 116 cases glycomer 631 (Biosyn) were used. All procedures were carried out by the same surgeon. Anastomosis related complication was detected in 7 cases (2.8%), some kind of anastomosis insufficiency--including minor leakage--in 5 cases (2.0%), but reoperation only in one case (0.4%) was required. There was no anastomosis related death. Authors overview the advantages of the technique, which is safe, cheap, easy to carry out, physiological and least harmful to the blood supply, so they recommend its use in the gastrointestinal surgery as a standard procedure.

AB - Authors evaluated the safety of single layer continuous sutured anastomosis technique with two different types of absorbable sutures in 252 anastomoses performed on 178 patients. In the prospective, randomized study 5 oesophagus, 26 stomach, 117 small intestine, 32 colonic, 29 pancreatic and 43 biliary anastomoses were performed. In 136 cases poliglecaprone 25 (Monocryl), in 116 cases glycomer 631 (Biosyn) were used. All procedures were carried out by the same surgeon. Anastomosis related complication was detected in 7 cases (2.8%), some kind of anastomosis insufficiency--including minor leakage--in 5 cases (2.0%), but reoperation only in one case (0.4%) was required. There was no anastomosis related death. Authors overview the advantages of the technique, which is safe, cheap, easy to carry out, physiological and least harmful to the blood supply, so they recommend its use in the gastrointestinal surgery as a standard procedure.

UR - http://www.scopus.com/inward/record.url?scp=0033108226&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033108226&partnerID=8YFLogxK

M3 - Article

VL - 52

SP - 63

EP - 66

JO - Magyar Sebeszet

JF - Magyar Sebeszet

SN - 0025-0295

IS - 2

ER -