Simultaneous dynamic neutron and gamma radiography

M. Balaskó, E. Sváb, L. Cser

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Equipment for dynamic neutron and gamma radiography has been developed at the 4.6 MW research reactor in Budapest, using thermal neutrons and gamma radiation obtained from the reactor. Radiography images are detected by scintillator screens and by low-light-level TV cameras, providing the possibility of visualizing medium-speed movements inside the investigated objects. The images are displayed on monitors and stored on video recorders. Some applications for nondestructive investigations are given.

Original languageEnglish
Pages (from-to)157-160
Number of pages4
JournalNDT International
Volume20
Issue number3
DOIs
Publication statusPublished - Jun 1987