Simple, single step potential difference measurement for the determination of the ultimate detection limit of ion selective electrodes

Róbert Bereczki, Boglárka Takács, R. Gyurcsányi, K. Tóth, G. Nagy, Jan Langmaier, Ernö Lindner

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A single step measurement is proposed for evaluating the ultimate detection limit of ion selective electrodes. The essence of the method is the calculation of the detection limit from a potential difference measured across a membrane in equilibrium with deionized water when it is challenged with a relatively concentrated primary or interfering ion solution on one of its sides. It is aimed for fast screening of novel ionophore candidates and for reexamining existing ones to sort out those which are adequate for selective, subnanomolar analysis. The feasibility and the practical usefulness of the method is demonstrated upon the characterization potassium ion-selective electrodes with novel, and well-known ionophores. The proposed potential difference-based method is coupled to subsequent exponential dilutions for the determination the response slopes, selectivity coefficients and detection limits of the tested electrodes. This combination of electrode testing protocols provides full characterization of the studied electrodes and a back to back comparison of the indirectly calculated and directly measured detection limits. The calibration of the electrodes in dilute solutions revealed the superior dynamic response properties of the electrodes with the covalently anchored ionophore in submicromolar concentrations.

Original languageEnglish
Pages (from-to)1245-1253
Number of pages9
JournalElectroanalysis
Volume18
Issue number13-14
DOIs
Publication statusPublished - Jul 2006

Fingerprint

Ion selective electrodes
Ionophores
Electrodes
Deionized water
Dilution
Dynamic response
Potassium
Screening
Calibration
Ions
Membranes
Testing

Keywords

  • Carrier based ion-selective electrodes
  • Covalently anchored ionophore
  • Detection limit
  • Potential difference measurement
  • Response range
  • Response time

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Simple, single step potential difference measurement for the determination of the ultimate detection limit of ion selective electrodes. / Bereczki, Róbert; Takács, Boglárka; Gyurcsányi, R.; Tóth, K.; Nagy, G.; Langmaier, Jan; Lindner, Ernö.

In: Electroanalysis, Vol. 18, No. 13-14, 07.2006, p. 1245-1253.

Research output: Contribution to journalArticle

@article{6150dfd6dc2d44638557103eaa5f7b0a,
title = "Simple, single step potential difference measurement for the determination of the ultimate detection limit of ion selective electrodes",
abstract = "A single step measurement is proposed for evaluating the ultimate detection limit of ion selective electrodes. The essence of the method is the calculation of the detection limit from a potential difference measured across a membrane in equilibrium with deionized water when it is challenged with a relatively concentrated primary or interfering ion solution on one of its sides. It is aimed for fast screening of novel ionophore candidates and for reexamining existing ones to sort out those which are adequate for selective, subnanomolar analysis. The feasibility and the practical usefulness of the method is demonstrated upon the characterization potassium ion-selective electrodes with novel, and well-known ionophores. The proposed potential difference-based method is coupled to subsequent exponential dilutions for the determination the response slopes, selectivity coefficients and detection limits of the tested electrodes. This combination of electrode testing protocols provides full characterization of the studied electrodes and a back to back comparison of the indirectly calculated and directly measured detection limits. The calibration of the electrodes in dilute solutions revealed the superior dynamic response properties of the electrodes with the covalently anchored ionophore in submicromolar concentrations.",
keywords = "Carrier based ion-selective electrodes, Covalently anchored ionophore, Detection limit, Potential difference measurement, Response range, Response time",
author = "R{\'o}bert Bereczki and Bogl{\'a}rka Tak{\'a}cs and R. Gyurcs{\'a}nyi and K. T{\'o}th and G. Nagy and Jan Langmaier and Ern{\"o} Lindner",
year = "2006",
month = "7",
doi = "10.1002/elan.200603521",
language = "English",
volume = "18",
pages = "1245--1253",
journal = "Electroanalysis",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "13-14",

}

TY - JOUR

T1 - Simple, single step potential difference measurement for the determination of the ultimate detection limit of ion selective electrodes

AU - Bereczki, Róbert

AU - Takács, Boglárka

AU - Gyurcsányi, R.

AU - Tóth, K.

AU - Nagy, G.

AU - Langmaier, Jan

AU - Lindner, Ernö

PY - 2006/7

Y1 - 2006/7

N2 - A single step measurement is proposed for evaluating the ultimate detection limit of ion selective electrodes. The essence of the method is the calculation of the detection limit from a potential difference measured across a membrane in equilibrium with deionized water when it is challenged with a relatively concentrated primary or interfering ion solution on one of its sides. It is aimed for fast screening of novel ionophore candidates and for reexamining existing ones to sort out those which are adequate for selective, subnanomolar analysis. The feasibility and the practical usefulness of the method is demonstrated upon the characterization potassium ion-selective electrodes with novel, and well-known ionophores. The proposed potential difference-based method is coupled to subsequent exponential dilutions for the determination the response slopes, selectivity coefficients and detection limits of the tested electrodes. This combination of electrode testing protocols provides full characterization of the studied electrodes and a back to back comparison of the indirectly calculated and directly measured detection limits. The calibration of the electrodes in dilute solutions revealed the superior dynamic response properties of the electrodes with the covalently anchored ionophore in submicromolar concentrations.

AB - A single step measurement is proposed for evaluating the ultimate detection limit of ion selective electrodes. The essence of the method is the calculation of the detection limit from a potential difference measured across a membrane in equilibrium with deionized water when it is challenged with a relatively concentrated primary or interfering ion solution on one of its sides. It is aimed for fast screening of novel ionophore candidates and for reexamining existing ones to sort out those which are adequate for selective, subnanomolar analysis. The feasibility and the practical usefulness of the method is demonstrated upon the characterization potassium ion-selective electrodes with novel, and well-known ionophores. The proposed potential difference-based method is coupled to subsequent exponential dilutions for the determination the response slopes, selectivity coefficients and detection limits of the tested electrodes. This combination of electrode testing protocols provides full characterization of the studied electrodes and a back to back comparison of the indirectly calculated and directly measured detection limits. The calibration of the electrodes in dilute solutions revealed the superior dynamic response properties of the electrodes with the covalently anchored ionophore in submicromolar concentrations.

KW - Carrier based ion-selective electrodes

KW - Covalently anchored ionophore

KW - Detection limit

KW - Potential difference measurement

KW - Response range

KW - Response time

UR - http://www.scopus.com/inward/record.url?scp=33746610280&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33746610280&partnerID=8YFLogxK

U2 - 10.1002/elan.200603521

DO - 10.1002/elan.200603521

M3 - Article

AN - SCOPUS:33746610280

VL - 18

SP - 1245

EP - 1253

JO - Electroanalysis

JF - Electroanalysis

SN - 1040-0397

IS - 13-14

ER -