Similarity between blackbody and synchrotron radiation analyzed by Tsallis entropy

Hiroyuki Iwasaki, Jun Kawai, Koretaka Yuge, A. Nagy

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

It is believed that blackbody and bremsstrahlung are completely different phenomena. However, their spectral shapes are somewhat similar to each other. We demonstrate that synchrotron radiation spectra, which are relativistic magnetic bremsstrahlung, can be approximated by blackbody radiation through Tsallis entropy under the dulite gas approximation at Tsallis non-extensive parameter q=1.05. The error of mean square is 4×10 -6 within the range of 5×10 4eV without adjusting any parameters. This approximation will be applied to more complex bremsstrahlung such as an X-ray tube.

Original languageEnglish
Pages (from-to)125-127
Number of pages3
JournalX-Ray Spectrometry
Volume41
Issue number3
DOIs
Publication statusPublished - May 2012

Fingerprint

X ray tubes
Synchrotron radiation
Entropy
Gases
Radiation

ASJC Scopus subject areas

  • Spectroscopy

Cite this

Similarity between blackbody and synchrotron radiation analyzed by Tsallis entropy. / Iwasaki, Hiroyuki; Kawai, Jun; Yuge, Koretaka; Nagy, A.

In: X-Ray Spectrometry, Vol. 41, No. 3, 05.2012, p. 125-127.

Research output: Contribution to journalArticle

Iwasaki, Hiroyuki ; Kawai, Jun ; Yuge, Koretaka ; Nagy, A. / Similarity between blackbody and synchrotron radiation analyzed by Tsallis entropy. In: X-Ray Spectrometry. 2012 ; Vol. 41, No. 3. pp. 125-127.
@article{619b432c83d143e5b53de1f8b8ff8501,
title = "Similarity between blackbody and synchrotron radiation analyzed by Tsallis entropy",
abstract = "It is believed that blackbody and bremsstrahlung are completely different phenomena. However, their spectral shapes are somewhat similar to each other. We demonstrate that synchrotron radiation spectra, which are relativistic magnetic bremsstrahlung, can be approximated by blackbody radiation through Tsallis entropy under the dulite gas approximation at Tsallis non-extensive parameter q=1.05. The error of mean square is 4×10 -6 within the range of 5×10 4eV without adjusting any parameters. This approximation will be applied to more complex bremsstrahlung such as an X-ray tube.",
author = "Hiroyuki Iwasaki and Jun Kawai and Koretaka Yuge and A. Nagy",
year = "2012",
month = "5",
doi = "10.1002/xrs.2362",
language = "English",
volume = "41",
pages = "125--127",
journal = "X-Ray Spectrometry",
issn = "0049-8246",
publisher = "John Wiley and Sons Ltd",
number = "3",

}

TY - JOUR

T1 - Similarity between blackbody and synchrotron radiation analyzed by Tsallis entropy

AU - Iwasaki, Hiroyuki

AU - Kawai, Jun

AU - Yuge, Koretaka

AU - Nagy, A.

PY - 2012/5

Y1 - 2012/5

N2 - It is believed that blackbody and bremsstrahlung are completely different phenomena. However, their spectral shapes are somewhat similar to each other. We demonstrate that synchrotron radiation spectra, which are relativistic magnetic bremsstrahlung, can be approximated by blackbody radiation through Tsallis entropy under the dulite gas approximation at Tsallis non-extensive parameter q=1.05. The error of mean square is 4×10 -6 within the range of 5×10 4eV without adjusting any parameters. This approximation will be applied to more complex bremsstrahlung such as an X-ray tube.

AB - It is believed that blackbody and bremsstrahlung are completely different phenomena. However, their spectral shapes are somewhat similar to each other. We demonstrate that synchrotron radiation spectra, which are relativistic magnetic bremsstrahlung, can be approximated by blackbody radiation through Tsallis entropy under the dulite gas approximation at Tsallis non-extensive parameter q=1.05. The error of mean square is 4×10 -6 within the range of 5×10 4eV without adjusting any parameters. This approximation will be applied to more complex bremsstrahlung such as an X-ray tube.

UR - http://www.scopus.com/inward/record.url?scp=84859432737&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859432737&partnerID=8YFLogxK

U2 - 10.1002/xrs.2362

DO - 10.1002/xrs.2362

M3 - Article

VL - 41

SP - 125

EP - 127

JO - X-Ray Spectrometry

JF - X-Ray Spectrometry

SN - 0049-8246

IS - 3

ER -