Scintilation detectors in conversion electron Mössbauer spectroscopy

Z. Kajcsos, Ch Sauer, W. Zinn, M. A C Ligtenberg

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Results of CEMS measurements performed in vacuum applying a channeltron and a low-noise thin-layer scintillation detector equipped with different types of thin-layer scintillators (e.g. P-47 CsI(Tl) of different thickness) are reported here. The experimental merits of different detectors for different Mïossbauer isotopes of samples are evaluated.

Original languageEnglish
Pages (from-to)1479-1482
Number of pages4
JournalHyperfine Interactions
Volume71
Issue number1-4
DOIs
Publication statusPublished - Apr 1992

Fingerprint

Scintillation counters
Electron spectroscopy
Isotopes
Phosphors
electron spectroscopy
Vacuum
Detectors
detectors
low noise
scintillation counters
scintillation
isotopes
vacuum
2-chloroethyl methyl sulfide

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Nuclear and High Energy Physics
  • Condensed Matter Physics
  • Physics and Astronomy(all)
  • Electronic, Optical and Magnetic Materials

Cite this

Scintilation detectors in conversion electron Mössbauer spectroscopy. / Kajcsos, Z.; Sauer, Ch; Zinn, W.; Ligtenberg, M. A C.

In: Hyperfine Interactions, Vol. 71, No. 1-4, 04.1992, p. 1479-1482.

Research output: Contribution to journalArticle

Kajcsos, Z. ; Sauer, Ch ; Zinn, W. ; Ligtenberg, M. A C. / Scintilation detectors in conversion electron Mössbauer spectroscopy. In: Hyperfine Interactions. 1992 ; Vol. 71, No. 1-4. pp. 1479-1482.
@article{d2064fd27a984b8dbbfe88c1bff37fb9,
title = "Scintilation detectors in conversion electron M{\"o}ssbauer spectroscopy",
abstract = "Results of CEMS measurements performed in vacuum applying a channeltron and a low-noise thin-layer scintillation detector equipped with different types of thin-layer scintillators (e.g. P-47 CsI(Tl) of different thickness) are reported here. The experimental merits of different detectors for different M{\"i}ossbauer isotopes of samples are evaluated.",
author = "Z. Kajcsos and Ch Sauer and W. Zinn and Ligtenberg, {M. A C}",
year = "1992",
month = "4",
doi = "10.1007/BF02397362",
language = "English",
volume = "71",
pages = "1479--1482",
journal = "Hyperfine Interaction",
issn = "0304-3843",
publisher = "Springer Netherlands",
number = "1-4",

}

TY - JOUR

T1 - Scintilation detectors in conversion electron Mössbauer spectroscopy

AU - Kajcsos, Z.

AU - Sauer, Ch

AU - Zinn, W.

AU - Ligtenberg, M. A C

PY - 1992/4

Y1 - 1992/4

N2 - Results of CEMS measurements performed in vacuum applying a channeltron and a low-noise thin-layer scintillation detector equipped with different types of thin-layer scintillators (e.g. P-47 CsI(Tl) of different thickness) are reported here. The experimental merits of different detectors for different Mïossbauer isotopes of samples are evaluated.

AB - Results of CEMS measurements performed in vacuum applying a channeltron and a low-noise thin-layer scintillation detector equipped with different types of thin-layer scintillators (e.g. P-47 CsI(Tl) of different thickness) are reported here. The experimental merits of different detectors for different Mïossbauer isotopes of samples are evaluated.

UR - http://www.scopus.com/inward/record.url?scp=34249835445&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34249835445&partnerID=8YFLogxK

U2 - 10.1007/BF02397362

DO - 10.1007/BF02397362

M3 - Article

AN - SCOPUS:34249835445

VL - 71

SP - 1479

EP - 1482

JO - Hyperfine Interaction

JF - Hyperfine Interaction

SN - 0304-3843

IS - 1-4

ER -