Resolution and detection of weak X-ray lines using a Si(Li) detector combined with absorbers

T. Papp, J. Pálinkás

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

A method to obtain high resolution and at the same time maintain high detection efficiency using absorbers in front of a Si(Li) detector is described. The method is analysed and its potentials are demonstrated by using it to resolve the Lα2 and Lα1 lines of Au and to measure the Ls and Lt lines of Pt excited by charged particle impact. The possible use of the method in other cases is discussed.

Original languageEnglish
Pages (from-to)209-215
Number of pages7
JournalActa Physica Hungarica
Volume65
Issue number2-3
DOIs
Publication statusPublished - Jun 1989

Fingerprint

absorbers
charged particles
high resolution
detectors
x rays

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Resolution and detection of weak X-ray lines using a Si(Li) detector combined with absorbers. / Papp, T.; Pálinkás, J.

In: Acta Physica Hungarica, Vol. 65, No. 2-3, 06.1989, p. 209-215.

Research output: Contribution to journalArticle

@article{dc7fcc94cfc74c8da94323f10c2e5727,
title = "Resolution and detection of weak X-ray lines using a Si(Li) detector combined with absorbers",
abstract = "A method to obtain high resolution and at the same time maintain high detection efficiency using absorbers in front of a Si(Li) detector is described. The method is analysed and its potentials are demonstrated by using it to resolve the Lα2 and Lα1 lines of Au and to measure the Ls and Lt lines of Pt excited by charged particle impact. The possible use of the method in other cases is discussed.",
author = "T. Papp and J. P{\'a}link{\'a}s",
year = "1989",
month = "6",
doi = "10.1007/BF03156065",
language = "English",
volume = "65",
pages = "209--215",
journal = "Acta Physica Hungarica",
issn = "0231-4428",
publisher = "Akademiai Kiado",
number = "2-3",

}

TY - JOUR

T1 - Resolution and detection of weak X-ray lines using a Si(Li) detector combined with absorbers

AU - Papp, T.

AU - Pálinkás, J.

PY - 1989/6

Y1 - 1989/6

N2 - A method to obtain high resolution and at the same time maintain high detection efficiency using absorbers in front of a Si(Li) detector is described. The method is analysed and its potentials are demonstrated by using it to resolve the Lα2 and Lα1 lines of Au and to measure the Ls and Lt lines of Pt excited by charged particle impact. The possible use of the method in other cases is discussed.

AB - A method to obtain high resolution and at the same time maintain high detection efficiency using absorbers in front of a Si(Li) detector is described. The method is analysed and its potentials are demonstrated by using it to resolve the Lα2 and Lα1 lines of Au and to measure the Ls and Lt lines of Pt excited by charged particle impact. The possible use of the method in other cases is discussed.

UR - http://www.scopus.com/inward/record.url?scp=77951512331&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951512331&partnerID=8YFLogxK

U2 - 10.1007/BF03156065

DO - 10.1007/BF03156065

M3 - Article

AN - SCOPUS:77951512331

VL - 65

SP - 209

EP - 215

JO - Acta Physica Hungarica

JF - Acta Physica Hungarica

SN - 0231-4428

IS - 2-3

ER -