Abstract

The values for total RBF measured with 133Xe and 86Rb methods are nearly equal to that measured simultaneously with an electromagnetic flowmeter. A high degree of correlation was found between the values estimated by the three methods. No significant correlation was, however, found in the perfusion of the individual kidney regions (cortex, outer and inner medulla) measured with 133Xe wash out and 86Rb uptake techniques.

Original languageEnglish
Pages (from-to)239-244
Number of pages6
JournalActa Medica Academiae Scientiarum Hungaricae
Volume32
Issue number3-4
Publication statusPublished - 1975

Fingerprint

Flowmeters
Renal Circulation
Electromagnetic Phenomena
Kidney Cortex
Perfusion

ASJC Scopus subject areas

  • Medicine(all)

Cite this

@article{ba30971f103046de85549dcbbe8dc085,
title = "Renal blood flow as measured with 133Xe wash out and 86Rb uptake techniques and with an electromagnetic flowmeter",
abstract = "The values for total RBF measured with 133Xe and 86Rb methods are nearly equal to that measured simultaneously with an electromagnetic flowmeter. A high degree of correlation was found between the values estimated by the three methods. No significant correlation was, however, found in the perfusion of the individual kidney regions (cortex, outer and inner medulla) measured with 133Xe wash out and 86Rb uptake techniques.",
author = "L. H{\'a}rsing and E. Posch and L. Rosivall and G. Szabo",
year = "1975",
language = "English",
volume = "32",
pages = "239--244",
journal = "Acta Medica Academiae Scientiarum Hungaricae",
issn = "0001-5989",
publisher = "Akademiai Kiado",
number = "3-4",

}

TY - JOUR

T1 - Renal blood flow as measured with 133Xe wash out and 86Rb uptake techniques and with an electromagnetic flowmeter

AU - Hársing, L.

AU - Posch, E.

AU - Rosivall, L.

AU - Szabo, G.

PY - 1975

Y1 - 1975

N2 - The values for total RBF measured with 133Xe and 86Rb methods are nearly equal to that measured simultaneously with an electromagnetic flowmeter. A high degree of correlation was found between the values estimated by the three methods. No significant correlation was, however, found in the perfusion of the individual kidney regions (cortex, outer and inner medulla) measured with 133Xe wash out and 86Rb uptake techniques.

AB - The values for total RBF measured with 133Xe and 86Rb methods are nearly equal to that measured simultaneously with an electromagnetic flowmeter. A high degree of correlation was found between the values estimated by the three methods. No significant correlation was, however, found in the perfusion of the individual kidney regions (cortex, outer and inner medulla) measured with 133Xe wash out and 86Rb uptake techniques.

UR - http://www.scopus.com/inward/record.url?scp=0016616282&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016616282&partnerID=8YFLogxK

M3 - Article

C2 - 139816

AN - SCOPUS:0016616282

VL - 32

SP - 239

EP - 244

JO - Acta Medica Academiae Scientiarum Hungaricae

JF - Acta Medica Academiae Scientiarum Hungaricae

SN - 0001-5989

IS - 3-4

ER -