Recommended nuclear data for use in the k0 standardization of neutron activation analysis

Frans De Corte, András Simonits

Research output: Contribution to journalArticle

213 Citations (Scopus)

Abstract

k0 factors (composite nuclear constants) for use in the k0 standardization of reactor neutron activation analysis were experimentally measured with great care in several laboratories. The recommended values thus obtained for the relevant gamma rays of 144 analytically interesting radionuclides are tabulated, together with evaluated values for their associated parameters such as resonance integral to thermal cross-section ratios and effective resonance energies. A classification is also given of the various activation-decay types, to which the data are strictly correlated.

Original languageEnglish
Pages (from-to)47-67
Number of pages21
JournalAtomic Data and Nuclear Data Tables
Volume85
Issue number1
DOIs
Publication statusPublished - Sep 2003

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Nuclear and High Energy Physics

Fingerprint Dive into the research topics of 'Recommended nuclear data for use in the k<sub>0</sub> standardization of neutron activation analysis'. Together they form a unique fingerprint.

  • Cite this