Abstract

The extensive use of plant protection products in urban and rural pest control obliges to develop valid analytical methods for their successful and reliable quality control. An analytical procedure for the simultaneous determination of famoxadone and cymoxanil, by reversed phase high performance liquid chromatography based on the use of a monolithic C18 column has been developed and validated. The method involved the extraction of the active ingredients by sonication of the sample with acetonitrile and direct injection on a reversed phase liquid chromatographic system. The repeatability of the method expressed as relative standard deviation (%RSD), was lower than 1 % for both compounds. The limits of quantification for famoxadone and cymoxanil were 10 and 16 µg mL(-1) respectively. The new method involves a considerable reduction in time for both sample preparation and analysis. The proposed analytical procedure is accurate and precise.

Original languageEnglish
Pages (from-to)775-780
Number of pages6
JournalBulletin of Environmental Contamination and Toxicology
Volume93
Issue number6
DOIs
Publication statusPublished - Dec 1 2014

Fingerprint

Pest control
Sonication
Direct injection
High performance liquid chromatography
Pesticides
Acetonitrile
Quality control
High Pressure Liquid Chromatography
Liquids
Pest Control
Reverse-Phase Chromatography
Quality Control
2-cyano-N-((ethylamino)carbonyl)-2-(methoxyimino)acetamide
famoxadon
Injections
acetonitrile

ASJC Scopus subject areas

  • Medicine(all)

Cite this

@article{a3162f25af2441648eb070a08946e264,
title = "Rapid determination of famoxadone and cymoxanil in commercial pesticide formulation by high performance liquid chromatography using a C18 monolithic rod column",
abstract = "The extensive use of plant protection products in urban and rural pest control obliges to develop valid analytical methods for their successful and reliable quality control. An analytical procedure for the simultaneous determination of famoxadone and cymoxanil, by reversed phase high performance liquid chromatography based on the use of a monolithic C18 column has been developed and validated. The method involved the extraction of the active ingredients by sonication of the sample with acetonitrile and direct injection on a reversed phase liquid chromatographic system. The repeatability of the method expressed as relative standard deviation ({\%}RSD), was lower than 1 {\%} for both compounds. The limits of quantification for famoxadone and cymoxanil were 10 and 16 µg mL(-1) respectively. The new method involves a considerable reduction in time for both sample preparation and analysis. The proposed analytical procedure is accurate and precise.",
author = "George Balayiannis and Helen Karasali and A. {\'A}mbrus",
year = "2014",
month = "12",
day = "1",
doi = "10.1007/s00128-014-1382-7",
language = "English",
volume = "93",
pages = "775--780",
journal = "Bulletin of Environmental Contamination and Toxicology",
issn = "0007-4861",
publisher = "Springer New York",
number = "6",

}

TY - JOUR

T1 - Rapid determination of famoxadone and cymoxanil in commercial pesticide formulation by high performance liquid chromatography using a C18 monolithic rod column

AU - Balayiannis, George

AU - Karasali, Helen

AU - Ámbrus, A.

PY - 2014/12/1

Y1 - 2014/12/1

N2 - The extensive use of plant protection products in urban and rural pest control obliges to develop valid analytical methods for their successful and reliable quality control. An analytical procedure for the simultaneous determination of famoxadone and cymoxanil, by reversed phase high performance liquid chromatography based on the use of a monolithic C18 column has been developed and validated. The method involved the extraction of the active ingredients by sonication of the sample with acetonitrile and direct injection on a reversed phase liquid chromatographic system. The repeatability of the method expressed as relative standard deviation (%RSD), was lower than 1 % for both compounds. The limits of quantification for famoxadone and cymoxanil were 10 and 16 µg mL(-1) respectively. The new method involves a considerable reduction in time for both sample preparation and analysis. The proposed analytical procedure is accurate and precise.

AB - The extensive use of plant protection products in urban and rural pest control obliges to develop valid analytical methods for their successful and reliable quality control. An analytical procedure for the simultaneous determination of famoxadone and cymoxanil, by reversed phase high performance liquid chromatography based on the use of a monolithic C18 column has been developed and validated. The method involved the extraction of the active ingredients by sonication of the sample with acetonitrile and direct injection on a reversed phase liquid chromatographic system. The repeatability of the method expressed as relative standard deviation (%RSD), was lower than 1 % for both compounds. The limits of quantification for famoxadone and cymoxanil were 10 and 16 µg mL(-1) respectively. The new method involves a considerable reduction in time for both sample preparation and analysis. The proposed analytical procedure is accurate and precise.

UR - http://www.scopus.com/inward/record.url?scp=84945288047&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84945288047&partnerID=8YFLogxK

U2 - 10.1007/s00128-014-1382-7

DO - 10.1007/s00128-014-1382-7

M3 - Article

C2 - 25236328

AN - SCOPUS:84945288047

VL - 93

SP - 775

EP - 780

JO - Bulletin of Environmental Contamination and Toxicology

JF - Bulletin of Environmental Contamination and Toxicology

SN - 0007-4861

IS - 6

ER -