Rapid and simple chromatographic separation of V(V) and V(IV) using KH-phthalate and their determination by flame atomic absorption spectrometry

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

A method was developed for the chromatographic separation of V(V) and V(IV) based on the different sorption forces of these vanadium species in C18 columns in presence of KH-phthalate. The vanadium species were detected with a flame atomic absorption spectrometer with acetylene/N2O flame. The detection limits (3σ) of V(V) and V(IV) were 0.18 μg/mL and 0.15 μg/mL, respectively. The relative standard deviations (N = 5) are 4.2% and 3.4% for 20-20 μg/mL V(V) and V(IV), respectively. The sampling frequency is 75/h. Because of the special interaction occurring between phthalate and V(IV) on the C18 column and the acetylene/N2O flame atomic absorption detection, practically no interferences can be detected even in large inorganic matrix.

Original languageEnglish
Pages (from-to)179-183
Number of pages5
JournalFresenius' journal of analytical chemistry
Volume360
Issue number2
Publication statusPublished - 1998

Fingerprint

Acetylene
Vanadium
Atomic absorption spectrometry
Spectrum Analysis
Limit of Detection
Spectrometers
Sorption
Sampling
phthalic acid

ASJC Scopus subject areas

  • Biochemistry

Cite this

@article{0746ccd846964239a76541d39d7f5f2b,
title = "Rapid and simple chromatographic separation of V(V) and V(IV) using KH-phthalate and their determination by flame atomic absorption spectrometry",
abstract = "A method was developed for the chromatographic separation of V(V) and V(IV) based on the different sorption forces of these vanadium species in C18 columns in presence of KH-phthalate. The vanadium species were detected with a flame atomic absorption spectrometer with acetylene/N2O flame. The detection limits (3σ) of V(V) and V(IV) were 0.18 μg/mL and 0.15 μg/mL, respectively. The relative standard deviations (N = 5) are 4.2{\%} and 3.4{\%} for 20-20 μg/mL V(V) and V(IV), respectively. The sampling frequency is 75/h. Because of the special interaction occurring between phthalate and V(IV) on the C18 column and the acetylene/N2O flame atomic absorption detection, practically no interferences can be detected even in large inorganic matrix.",
author = "A. G{\'a}sp{\'a}r and J. Posta",
year = "1998",
language = "English",
volume = "360",
pages = "179--183",
journal = "Fresenius Zeitschrift fur Analytische Chemie",
issn = "1618-2642",
publisher = "Springer Verlag",
number = "2",

}

TY - JOUR

T1 - Rapid and simple chromatographic separation of V(V) and V(IV) using KH-phthalate and their determination by flame atomic absorption spectrometry

AU - Gáspár, A.

AU - Posta, J.

PY - 1998

Y1 - 1998

N2 - A method was developed for the chromatographic separation of V(V) and V(IV) based on the different sorption forces of these vanadium species in C18 columns in presence of KH-phthalate. The vanadium species were detected with a flame atomic absorption spectrometer with acetylene/N2O flame. The detection limits (3σ) of V(V) and V(IV) were 0.18 μg/mL and 0.15 μg/mL, respectively. The relative standard deviations (N = 5) are 4.2% and 3.4% for 20-20 μg/mL V(V) and V(IV), respectively. The sampling frequency is 75/h. Because of the special interaction occurring between phthalate and V(IV) on the C18 column and the acetylene/N2O flame atomic absorption detection, practically no interferences can be detected even in large inorganic matrix.

AB - A method was developed for the chromatographic separation of V(V) and V(IV) based on the different sorption forces of these vanadium species in C18 columns in presence of KH-phthalate. The vanadium species were detected with a flame atomic absorption spectrometer with acetylene/N2O flame. The detection limits (3σ) of V(V) and V(IV) were 0.18 μg/mL and 0.15 μg/mL, respectively. The relative standard deviations (N = 5) are 4.2% and 3.4% for 20-20 μg/mL V(V) and V(IV), respectively. The sampling frequency is 75/h. Because of the special interaction occurring between phthalate and V(IV) on the C18 column and the acetylene/N2O flame atomic absorption detection, practically no interferences can be detected even in large inorganic matrix.

UR - http://www.scopus.com/inward/record.url?scp=0038271098&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0038271098&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0038271098

VL - 360

SP - 179

EP - 183

JO - Fresenius Zeitschrift fur Analytische Chemie

JF - Fresenius Zeitschrift fur Analytische Chemie

SN - 1618-2642

IS - 2

ER -