Pseudophakic accommodation and pseudoaccommodation under physiological conditions measured with partial coherence interferometry

Alexis Tsorbatzoglou, Gábor Németh, János Máth, András Berta

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

Purpose: To distinguish pseudophakic accommodation from pseudoaccommodation by measuring the physiologically and pharmacologically induced anterior chamber depth (ACD) shifts. Setting: Department of Ophthalmology, University of Debrecen, Debrecen, Hungary. Methods: This study comprised 100 pseudophakic eyes of 79 patients. Forty patients (Group 1) received the AcrySof MA60AC intraocular lens (IOL) (Alcon Laboratories), 50 patients (Group 2) received the SA60AT IOL (Alcon Laboratories), and 10 patients (Group 3) received the apodized diffractive SA60D3 ReSTOR IOL. Visual function was evaluated a mean of 10.2 months ± 9.2 (SD) postoperatively, and the total pseudoaccommodative amplitude was determined with a defocusing technique. To distinguish pseudophakic accommodation from pseudoaccommodation, ACD measurements were performed using partial coherence interferometry during distance fixation and physiologic accommodation after pharmacologic relaxation of the ciliary muscle. Results: Best corrected distance and near visual acuities were similar in the 3 groups (P = .75 and P = .08, respectively). Distance corrected near visual acuity was significantly better in Group 3 (P<.001), with all eyes achieving J1 or better. Three percent in Group 1 and 8% in Group 2 achieved J1 or better. Subjective accommodation was similar in Groups 1 and 2 (-0.82 ± 0.18 diopter [D] and -1.00 ± 0.35 D, respectively; P = .3). Group 3 had an accommodation curve with 2 peaks. Intraocular lens movement differences between the groups were not significant (physiologic stimulus: P = .07; cyclopentolate: P = .46), and significant ACD shifts from baseline were not detected (physiologic stimulus: P = .14; cyclopentolate: P = .10). Conclusions: Pseudoaccommodative amplitude of the investigated monofocal IOLs was independent of IOL movement. Anterior shift did not affect good near visual acuity with the AcrySof ReSTOR IOL.

Original languageEnglish
Pages (from-to)1345-1350
Number of pages6
JournalJournal of Cataract and Refractive Surgery
Volume32
Issue number8
DOIs
Publication statusPublished - Aug 1 2006

ASJC Scopus subject areas

  • Surgery
  • Ophthalmology
  • Sensory Systems

Fingerprint Dive into the research topics of 'Pseudophakic accommodation and pseudoaccommodation under physiological conditions measured with partial coherence interferometry'. Together they form a unique fingerprint.

  • Cite this