Proportional chamber with 1 mm spacing of the signal wires

V. P. Balandin, I. Veresh, B. N. Gus'kov, V. M. Grebenyuk, P. Zalan, N. O. Kadagidze, V. R. Krastev, N. A. Kuz'min, A. N. Maksimov, P. K. Man'yakov, G. V. Melitarui, Ya Pazoni, T. G. Pitskehelauri, E. A. Chudakov, V. K. Yudin

Research output: Contribution to journalArticle

Abstract

The construction of a three-coordinate proportional chamber with a 256 x 256 mm working region and with 1.0 and 2.0 mm spacing of the signal wires is described and its characteristics are presented. A charged-particle recording efficiency of 99% was achieved with the gas mixture Ar + 20% C4H10 + 2% C3H8O2 + 0.3% CF3Br. The plateau on the efficiency curve equaled 750 and greater than 1000 V and the spatial resolution equaled 0.318 and 0.67 mm for planes with spacings of 1 and 2 mm respectively. The effect of proportional chambers on the accuracy with which the coordinates of the vertices of the multitrack events were determined with a BIS-2 spectrometer was studied.

Original languageEnglish
Pages (from-to)1307-1313
Number of pages7
JournalInstruments and experimental techniques New York
Volume30
Issue number6 pt 1
Publication statusPublished - May 1988

Fingerprint

chambers
spacing
wire
Wire
Charged particles
Gas mixtures
gas mixtures
Spectrometers
plateaus
charged particles
apexes
spatial resolution
recording
spectrometers
curves

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Cite this

Balandin, V. P., Veresh, I., Gus'kov, B. N., Grebenyuk, V. M., Zalan, P., Kadagidze, N. O., ... Yudin, V. K. (1988). Proportional chamber with 1 mm spacing of the signal wires. Instruments and experimental techniques New York, 30(6 pt 1), 1307-1313.

Proportional chamber with 1 mm spacing of the signal wires. / Balandin, V. P.; Veresh, I.; Gus'kov, B. N.; Grebenyuk, V. M.; Zalan, P.; Kadagidze, N. O.; Krastev, V. R.; Kuz'min, N. A.; Maksimov, A. N.; Man'yakov, P. K.; Melitarui, G. V.; Pazoni, Ya; Pitskehelauri, T. G.; Chudakov, E. A.; Yudin, V. K.

In: Instruments and experimental techniques New York, Vol. 30, No. 6 pt 1, 05.1988, p. 1307-1313.

Research output: Contribution to journalArticle

Balandin, VP, Veresh, I, Gus'kov, BN, Grebenyuk, VM, Zalan, P, Kadagidze, NO, Krastev, VR, Kuz'min, NA, Maksimov, AN, Man'yakov, PK, Melitarui, GV, Pazoni, Y, Pitskehelauri, TG, Chudakov, EA & Yudin, VK 1988, 'Proportional chamber with 1 mm spacing of the signal wires', Instruments and experimental techniques New York, vol. 30, no. 6 pt 1, pp. 1307-1313.
Balandin VP, Veresh I, Gus'kov BN, Grebenyuk VM, Zalan P, Kadagidze NO et al. Proportional chamber with 1 mm spacing of the signal wires. Instruments and experimental techniques New York. 1988 May;30(6 pt 1):1307-1313.
Balandin, V. P. ; Veresh, I. ; Gus'kov, B. N. ; Grebenyuk, V. M. ; Zalan, P. ; Kadagidze, N. O. ; Krastev, V. R. ; Kuz'min, N. A. ; Maksimov, A. N. ; Man'yakov, P. K. ; Melitarui, G. V. ; Pazoni, Ya ; Pitskehelauri, T. G. ; Chudakov, E. A. ; Yudin, V. K. / Proportional chamber with 1 mm spacing of the signal wires. In: Instruments and experimental techniques New York. 1988 ; Vol. 30, No. 6 pt 1. pp. 1307-1313.
@article{0e3532e3dfd24161a25d7fe1ffeffe9b,
title = "Proportional chamber with 1 mm spacing of the signal wires",
abstract = "The construction of a three-coordinate proportional chamber with a 256 x 256 mm working region and with 1.0 and 2.0 mm spacing of the signal wires is described and its characteristics are presented. A charged-particle recording efficiency of 99{\%} was achieved with the gas mixture Ar + 20{\%} C4H10 + 2{\%} C3H8O2 + 0.3{\%} CF3Br. The plateau on the efficiency curve equaled 750 and greater than 1000 V and the spatial resolution equaled 0.318 and 0.67 mm for planes with spacings of 1 and 2 mm respectively. The effect of proportional chambers on the accuracy with which the coordinates of the vertices of the multitrack events were determined with a BIS-2 spectrometer was studied.",
author = "Balandin, {V. P.} and I. Veresh and Gus'kov, {B. N.} and Grebenyuk, {V. M.} and P. Zalan and Kadagidze, {N. O.} and Krastev, {V. R.} and Kuz'min, {N. A.} and Maksimov, {A. N.} and Man'yakov, {P. K.} and Melitarui, {G. V.} and Ya Pazoni and Pitskehelauri, {T. G.} and Chudakov, {E. A.} and Yudin, {V. K.}",
year = "1988",
month = "5",
language = "English",
volume = "30",
pages = "1307--1313",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "6 pt 1",

}

TY - JOUR

T1 - Proportional chamber with 1 mm spacing of the signal wires

AU - Balandin, V. P.

AU - Veresh, I.

AU - Gus'kov, B. N.

AU - Grebenyuk, V. M.

AU - Zalan, P.

AU - Kadagidze, N. O.

AU - Krastev, V. R.

AU - Kuz'min, N. A.

AU - Maksimov, A. N.

AU - Man'yakov, P. K.

AU - Melitarui, G. V.

AU - Pazoni, Ya

AU - Pitskehelauri, T. G.

AU - Chudakov, E. A.

AU - Yudin, V. K.

PY - 1988/5

Y1 - 1988/5

N2 - The construction of a three-coordinate proportional chamber with a 256 x 256 mm working region and with 1.0 and 2.0 mm spacing of the signal wires is described and its characteristics are presented. A charged-particle recording efficiency of 99% was achieved with the gas mixture Ar + 20% C4H10 + 2% C3H8O2 + 0.3% CF3Br. The plateau on the efficiency curve equaled 750 and greater than 1000 V and the spatial resolution equaled 0.318 and 0.67 mm for planes with spacings of 1 and 2 mm respectively. The effect of proportional chambers on the accuracy with which the coordinates of the vertices of the multitrack events were determined with a BIS-2 spectrometer was studied.

AB - The construction of a three-coordinate proportional chamber with a 256 x 256 mm working region and with 1.0 and 2.0 mm spacing of the signal wires is described and its characteristics are presented. A charged-particle recording efficiency of 99% was achieved with the gas mixture Ar + 20% C4H10 + 2% C3H8O2 + 0.3% CF3Br. The plateau on the efficiency curve equaled 750 and greater than 1000 V and the spatial resolution equaled 0.318 and 0.67 mm for planes with spacings of 1 and 2 mm respectively. The effect of proportional chambers on the accuracy with which the coordinates of the vertices of the multitrack events were determined with a BIS-2 spectrometer was studied.

UR - http://www.scopus.com/inward/record.url?scp=0024001596&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024001596&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0024001596

VL - 30

SP - 1307

EP - 1313

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 6 pt 1

ER -