The authors analysed changes in the tissues following hip joint implantations in 14 cases. The interval between implantation and histological examination varied from 2 wk to 15 yr. The authors found, that on the inner layer of the joint capsule immediate to the implant, a metal- proteinate layer developed, and cobalt, nickel, chromium, particles of implant origin were demonstrated later in the mesenchymal tissues as well. In the fat tissue around the hip joint, cobalt and chromium, in the regional lymph nodes, cobalt, chromium and nickel particles were found; there were no metal deposits in the muscles. Acrylic bone cement particles in the joint capsule, in the bone marrow of the distal part of the femur, were found, but they were not present in the lymph nodes. The authors discuss the histological reaction due to metal and acrylic particles and their histological identification.

Original languageEnglish
Pages (from-to)167-175
Number of pages9
JournalMagyar Traumatologia Orthopaedia es Helyreallito Sebeszet
Volume21
Issue number3
Publication statusPublished - 1978

Fingerprint

Hip Joint
Chromium
Cobalt
Joint Capsule
Metals
Nickel
Lymph Nodes
Polymethyl Methacrylate
Femur
Bone Marrow
Fats
Muscles

ASJC Scopus subject areas

  • Surgery

Cite this

Products due to wear in the tissues around the hip joint following hip joint implantations. / Józsa, L.; Szilagyi, I.; Reffy, A.

In: Magyar Traumatologia Orthopaedia es Helyreallito Sebeszet, Vol. 21, No. 3, 1978, p. 167-175.

Research output: Contribution to journalArticle

@article{5b549fb39108428fb23e349c24631168,
title = "Products due to wear in the tissues around the hip joint following hip joint implantations",
abstract = "The authors analysed changes in the tissues following hip joint implantations in 14 cases. The interval between implantation and histological examination varied from 2 wk to 15 yr. The authors found, that on the inner layer of the joint capsule immediate to the implant, a metal- proteinate layer developed, and cobalt, nickel, chromium, particles of implant origin were demonstrated later in the mesenchymal tissues as well. In the fat tissue around the hip joint, cobalt and chromium, in the regional lymph nodes, cobalt, chromium and nickel particles were found; there were no metal deposits in the muscles. Acrylic bone cement particles in the joint capsule, in the bone marrow of the distal part of the femur, were found, but they were not present in the lymph nodes. The authors discuss the histological reaction due to metal and acrylic particles and their histological identification.",
author = "L. J{\'o}zsa and I. Szilagyi and A. Reffy",
year = "1978",
language = "English",
volume = "21",
pages = "167--175",
journal = "Magyar Traumatologia Orthopaedia es Helyreallito Sebeszet",
issn = "0025-0317",
publisher = "Hungarian Traumatology Society",
number = "3",

}

TY - JOUR

T1 - Products due to wear in the tissues around the hip joint following hip joint implantations

AU - Józsa, L.

AU - Szilagyi, I.

AU - Reffy, A.

PY - 1978

Y1 - 1978

N2 - The authors analysed changes in the tissues following hip joint implantations in 14 cases. The interval between implantation and histological examination varied from 2 wk to 15 yr. The authors found, that on the inner layer of the joint capsule immediate to the implant, a metal- proteinate layer developed, and cobalt, nickel, chromium, particles of implant origin were demonstrated later in the mesenchymal tissues as well. In the fat tissue around the hip joint, cobalt and chromium, in the regional lymph nodes, cobalt, chromium and nickel particles were found; there were no metal deposits in the muscles. Acrylic bone cement particles in the joint capsule, in the bone marrow of the distal part of the femur, were found, but they were not present in the lymph nodes. The authors discuss the histological reaction due to metal and acrylic particles and their histological identification.

AB - The authors analysed changes in the tissues following hip joint implantations in 14 cases. The interval between implantation and histological examination varied from 2 wk to 15 yr. The authors found, that on the inner layer of the joint capsule immediate to the implant, a metal- proteinate layer developed, and cobalt, nickel, chromium, particles of implant origin were demonstrated later in the mesenchymal tissues as well. In the fat tissue around the hip joint, cobalt and chromium, in the regional lymph nodes, cobalt, chromium and nickel particles were found; there were no metal deposits in the muscles. Acrylic bone cement particles in the joint capsule, in the bone marrow of the distal part of the femur, were found, but they were not present in the lymph nodes. The authors discuss the histological reaction due to metal and acrylic particles and their histological identification.

UR - http://www.scopus.com/inward/record.url?scp=0018213068&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018213068&partnerID=8YFLogxK

M3 - Article

VL - 21

SP - 167

EP - 175

JO - Magyar Traumatologia Orthopaedia es Helyreallito Sebeszet

JF - Magyar Traumatologia Orthopaedia es Helyreallito Sebeszet

SN - 0025-0317

IS - 3

ER -