Predictors of Cerebral Microembolization during Phased Radiofrequency Ablation of Atrial Fibrillation: Role of the Ongoing Rhythm and the Site of Energy Delivery

Edina Nagy-Balo, Alexandra Kiss, Catherine Condie, Mark Stewart, I. Édes, Zoltan Csanadi

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Background Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging, and a high microembolic signal (MES) count detected by transcranial Doppler. We investigated the potential effects of the ongoing rhythm and the target vein during energy delivery (ED) on MES generation during PVAC ablations. Methods and Results A total of 735 EDs during 48 PVAC ablations were analyzed. MES counts were recorded for each ED and time-stamped for correlation with the ongoing rhythm and the target vein for each ED. Significantly higher MES counts were observed during ablations of the left-sided as compared with the right-sided pulmonary veins (P = 0.0003). Similarly, higher MES counts were detected during EDs in atrial fibrillation as compared with sinus rhythm when the temperature was >56C (P <0.0001). The ongoing rhythm had no effect on the number of MESs at lower temperatures during ablation. Conclusions Both the ongoing rhythm during ED and the site of ablation influence microembolus generation during PVAC ablation procedures.

Original languageEnglish
Pages (from-to)1436-1441
Number of pages6
JournalPACE - Pacing and Clinical Electrophysiology
Volume37
Issue number11
DOIs
Publication statusPublished - Nov 1 2014

Fingerprint

Pulmonary Veins
Atrial Fibrillation
Catheter Ablation
Veins
Diffusion Magnetic Resonance Imaging
Temperature
Incidence
Brain

Keywords

  • atrial fibrillation
  • GENius generator
  • pulmonary vein isolation
  • PVAC catheter

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Medicine(all)

Cite this

Predictors of Cerebral Microembolization during Phased Radiofrequency Ablation of Atrial Fibrillation : Role of the Ongoing Rhythm and the Site of Energy Delivery. / Nagy-Balo, Edina; Kiss, Alexandra; Condie, Catherine; Stewart, Mark; Édes, I.; Csanadi, Zoltan.

In: PACE - Pacing and Clinical Electrophysiology, Vol. 37, No. 11, 01.11.2014, p. 1436-1441.

Research output: Contribution to journalArticle

@article{2dd01d9e4fd6477ba7ff78cb67a44818,
title = "Predictors of Cerebral Microembolization during Phased Radiofrequency Ablation of Atrial Fibrillation: Role of the Ongoing Rhythm and the Site of Energy Delivery",
abstract = "Background Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging, and a high microembolic signal (MES) count detected by transcranial Doppler. We investigated the potential effects of the ongoing rhythm and the target vein during energy delivery (ED) on MES generation during PVAC ablations. Methods and Results A total of 735 EDs during 48 PVAC ablations were analyzed. MES counts were recorded for each ED and time-stamped for correlation with the ongoing rhythm and the target vein for each ED. Significantly higher MES counts were observed during ablations of the left-sided as compared with the right-sided pulmonary veins (P = 0.0003). Similarly, higher MES counts were detected during EDs in atrial fibrillation as compared with sinus rhythm when the temperature was >56C (P <0.0001). The ongoing rhythm had no effect on the number of MESs at lower temperatures during ablation. Conclusions Both the ongoing rhythm during ED and the site of ablation influence microembolus generation during PVAC ablation procedures.",
keywords = "atrial fibrillation, GENius generator, pulmonary vein isolation, PVAC catheter",
author = "Edina Nagy-Balo and Alexandra Kiss and Catherine Condie and Mark Stewart and I. {\'E}des and Zoltan Csanadi",
year = "2014",
month = "11",
day = "1",
doi = "10.1111/pace.12454",
language = "English",
volume = "37",
pages = "1436--1441",
journal = "PACE - Pacing and Clinical Electrophysiology",
issn = "0147-8389",
publisher = "Wiley-Blackwell",
number = "11",

}

TY - JOUR

T1 - Predictors of Cerebral Microembolization during Phased Radiofrequency Ablation of Atrial Fibrillation

T2 - Role of the Ongoing Rhythm and the Site of Energy Delivery

AU - Nagy-Balo, Edina

AU - Kiss, Alexandra

AU - Condie, Catherine

AU - Stewart, Mark

AU - Édes, I.

AU - Csanadi, Zoltan

PY - 2014/11/1

Y1 - 2014/11/1

N2 - Background Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging, and a high microembolic signal (MES) count detected by transcranial Doppler. We investigated the potential effects of the ongoing rhythm and the target vein during energy delivery (ED) on MES generation during PVAC ablations. Methods and Results A total of 735 EDs during 48 PVAC ablations were analyzed. MES counts were recorded for each ED and time-stamped for correlation with the ongoing rhythm and the target vein for each ED. Significantly higher MES counts were observed during ablations of the left-sided as compared with the right-sided pulmonary veins (P = 0.0003). Similarly, higher MES counts were detected during EDs in atrial fibrillation as compared with sinus rhythm when the temperature was >56C (P <0.0001). The ongoing rhythm had no effect on the number of MESs at lower temperatures during ablation. Conclusions Both the ongoing rhythm during ED and the site of ablation influence microembolus generation during PVAC ablation procedures.

AB - Background Pulmonary vein isolation with phased radiofrequency current and use of a pulmonary vein ablation catheter (PVAC) has recently been associated with a high incidence of clinically silent brain infarcts on diffusion-weighted magnetic resonance imaging, and a high microembolic signal (MES) count detected by transcranial Doppler. We investigated the potential effects of the ongoing rhythm and the target vein during energy delivery (ED) on MES generation during PVAC ablations. Methods and Results A total of 735 EDs during 48 PVAC ablations were analyzed. MES counts were recorded for each ED and time-stamped for correlation with the ongoing rhythm and the target vein for each ED. Significantly higher MES counts were observed during ablations of the left-sided as compared with the right-sided pulmonary veins (P = 0.0003). Similarly, higher MES counts were detected during EDs in atrial fibrillation as compared with sinus rhythm when the temperature was >56C (P <0.0001). The ongoing rhythm had no effect on the number of MESs at lower temperatures during ablation. Conclusions Both the ongoing rhythm during ED and the site of ablation influence microembolus generation during PVAC ablation procedures.

KW - atrial fibrillation

KW - GENius generator

KW - pulmonary vein isolation

KW - PVAC catheter

UR - http://www.scopus.com/inward/record.url?scp=84937511350&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937511350&partnerID=8YFLogxK

U2 - 10.1111/pace.12454

DO - 10.1111/pace.12454

M3 - Article

C2 - 25130865

AN - SCOPUS:84937511350

VL - 37

SP - 1436

EP - 1441

JO - PACE - Pacing and Clinical Electrophysiology

JF - PACE - Pacing and Clinical Electrophysiology

SN - 0147-8389

IS - 11

ER -