Fogászati implantátumok csontintegrációjának klinikai vizsgálatával szerzett tapasztalataink.

Translated title of the contribution: [Possibilities of clinical testing of osseointegration in oral implants].

Attila Szucs, Tamás Divinyi, Ferenc Koppány, Péter Bujtár, Dániel Veres, J. Barabás

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The osseointegration of oral implants is of utmost importance as far as the success of implant prosthetics is concerned. In clinical practice osseointegration can only be tested indirectly. The loading of implants is usually linked to osseointegration as a condition. Under some circumstances implants can be loaded before osseointegration is completed. The present study reviews the various methods of testing osseointegration and the conditions of immediate loading. In the present study the changes in the stability of 59 implants restored with screw-retained superstructures and partly immediately loaded, were observed over a period of several years, with the help of the Periotest method. Based on the statistical evaluation of the results, a significant correlation was found between implant insertion torque and primary stability. A difference was found between the stability of implants in the upper and lower jaws. A typical curve in the temporal changes of implant stability was described.

Original languageHungarian
Pages (from-to)55-63
Number of pages9
JournalFogorvosi szemle
Volume104
Issue number2
Publication statusPublished - Jun 2011

Fingerprint

Osseointegration
Maxilla
Torque

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Fogászati implantátumok csontintegrációjának klinikai vizsgálatával szerzett tapasztalataink. / Szucs, Attila; Divinyi, Tamás; Koppány, Ferenc; Bujtár, Péter; Veres, Dániel; Barabás, J.

In: Fogorvosi szemle, Vol. 104, No. 2, 06.2011, p. 55-63.

Research output: Contribution to journalArticle

Szucs, A, Divinyi, T, Koppány, F, Bujtár, P, Veres, D & Barabás, J 2011, 'Fogászati implantátumok csontintegrációjának klinikai vizsgálatával szerzett tapasztalataink.', Fogorvosi szemle, vol. 104, no. 2, pp. 55-63.
Szucs, Attila ; Divinyi, Tamás ; Koppány, Ferenc ; Bujtár, Péter ; Veres, Dániel ; Barabás, J. / Fogászati implantátumok csontintegrációjának klinikai vizsgálatával szerzett tapasztalataink. In: Fogorvosi szemle. 2011 ; Vol. 104, No. 2. pp. 55-63.
@article{aa3d006cec6547f68534524c3a806f03,
title = "Fog{\'a}szati implant{\'a}tumok csontintegr{\'a}ci{\'o}j{\'a}nak klinikai vizsg{\'a}lat{\'a}val szerzett tapasztalataink.",
abstract = "The osseointegration of oral implants is of utmost importance as far as the success of implant prosthetics is concerned. In clinical practice osseointegration can only be tested indirectly. The loading of implants is usually linked to osseointegration as a condition. Under some circumstances implants can be loaded before osseointegration is completed. The present study reviews the various methods of testing osseointegration and the conditions of immediate loading. In the present study the changes in the stability of 59 implants restored with screw-retained superstructures and partly immediately loaded, were observed over a period of several years, with the help of the Periotest method. Based on the statistical evaluation of the results, a significant correlation was found between implant insertion torque and primary stability. A difference was found between the stability of implants in the upper and lower jaws. A typical curve in the temporal changes of implant stability was described.",
author = "Attila Szucs and Tam{\'a}s Divinyi and Ferenc Kopp{\'a}ny and P{\'e}ter Bujt{\'a}r and D{\'a}niel Veres and J. Barab{\'a}s",
year = "2011",
month = "6",
language = "Hungarian",
volume = "104",
pages = "55--63",
journal = "Fogorvosi szemle",
issn = "0015-5314",
publisher = "Ifjusagi Lapkiado Vallalat",
number = "2",

}

TY - JOUR

T1 - Fogászati implantátumok csontintegrációjának klinikai vizsgálatával szerzett tapasztalataink.

AU - Szucs, Attila

AU - Divinyi, Tamás

AU - Koppány, Ferenc

AU - Bujtár, Péter

AU - Veres, Dániel

AU - Barabás, J.

PY - 2011/6

Y1 - 2011/6

N2 - The osseointegration of oral implants is of utmost importance as far as the success of implant prosthetics is concerned. In clinical practice osseointegration can only be tested indirectly. The loading of implants is usually linked to osseointegration as a condition. Under some circumstances implants can be loaded before osseointegration is completed. The present study reviews the various methods of testing osseointegration and the conditions of immediate loading. In the present study the changes in the stability of 59 implants restored with screw-retained superstructures and partly immediately loaded, were observed over a period of several years, with the help of the Periotest method. Based on the statistical evaluation of the results, a significant correlation was found between implant insertion torque and primary stability. A difference was found between the stability of implants in the upper and lower jaws. A typical curve in the temporal changes of implant stability was described.

AB - The osseointegration of oral implants is of utmost importance as far as the success of implant prosthetics is concerned. In clinical practice osseointegration can only be tested indirectly. The loading of implants is usually linked to osseointegration as a condition. Under some circumstances implants can be loaded before osseointegration is completed. The present study reviews the various methods of testing osseointegration and the conditions of immediate loading. In the present study the changes in the stability of 59 implants restored with screw-retained superstructures and partly immediately loaded, were observed over a period of several years, with the help of the Periotest method. Based on the statistical evaluation of the results, a significant correlation was found between implant insertion torque and primary stability. A difference was found between the stability of implants in the upper and lower jaws. A typical curve in the temporal changes of implant stability was described.

UR - http://www.scopus.com/inward/record.url?scp=80051643860&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80051643860&partnerID=8YFLogxK

M3 - Article

VL - 104

SP - 55

EP - 63

JO - Fogorvosi szemle

JF - Fogorvosi szemle

SN - 0015-5314

IS - 2

ER -