Position-sensitive ion detection in precision Penning trap mass spectrometry

G. Eitel, M. Block, A. Czasch, M. Dworschak, S. George, O. Jagutzki, J. Ketelaer, J. Ketter, S. Nagy, D. Rodríguez, C. Smorra, K. Blaum

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.

Original languageEnglish
Pages (from-to)475-483
Number of pages9
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume606
Issue number3
DOIs
Publication statusPublished - Jul 21 2009

Fingerprint

Mass spectrometry
mass spectroscopy
traps
Ions
ions
Detectors
Cyclotron resonance
ion motion
detectors
Mass spectrometers
cyclotron resonance
mass spectrometers
Monitoring
simulation

Keywords

  • Beam diagnostics
  • Delay-line detector
  • Ion optics
  • Penning trap mass spectrometry
  • Position-sensitive ion detection
  • TOF-ICR

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Position-sensitive ion detection in precision Penning trap mass spectrometry. / Eitel, G.; Block, M.; Czasch, A.; Dworschak, M.; George, S.; Jagutzki, O.; Ketelaer, J.; Ketter, J.; Nagy, S.; Rodríguez, D.; Smorra, C.; Blaum, K.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 606, No. 3, 21.07.2009, p. 475-483.

Research output: Contribution to journalArticle

Eitel, G, Block, M, Czasch, A, Dworschak, M, George, S, Jagutzki, O, Ketelaer, J, Ketter, J, Nagy, S, Rodríguez, D, Smorra, C & Blaum, K 2009, 'Position-sensitive ion detection in precision Penning trap mass spectrometry', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 606, no. 3, pp. 475-483. https://doi.org/10.1016/j.nima.2009.04.046
Eitel, G. ; Block, M. ; Czasch, A. ; Dworschak, M. ; George, S. ; Jagutzki, O. ; Ketelaer, J. ; Ketter, J. ; Nagy, S. ; Rodríguez, D. ; Smorra, C. ; Blaum, K. / Position-sensitive ion detection in precision Penning trap mass spectrometry. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2009 ; Vol. 606, No. 3. pp. 475-483.
@article{3265235067e9419682b467c94b7724db,
title = "Position-sensitive ion detection in precision Penning trap mass spectrometry",
abstract = "A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.",
keywords = "Beam diagnostics, Delay-line detector, Ion optics, Penning trap mass spectrometry, Position-sensitive ion detection, TOF-ICR",
author = "G. Eitel and M. Block and A. Czasch and M. Dworschak and S. George and O. Jagutzki and J. Ketelaer and J. Ketter and S. Nagy and D. Rodr{\'i}guez and C. Smorra and K. Blaum",
year = "2009",
month = "7",
day = "21",
doi = "10.1016/j.nima.2009.04.046",
language = "English",
volume = "606",
pages = "475--483",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "3",

}

TY - JOUR

T1 - Position-sensitive ion detection in precision Penning trap mass spectrometry

AU - Eitel, G.

AU - Block, M.

AU - Czasch, A.

AU - Dworschak, M.

AU - George, S.

AU - Jagutzki, O.

AU - Ketelaer, J.

AU - Ketter, J.

AU - Nagy, S.

AU - Rodríguez, D.

AU - Smorra, C.

AU - Blaum, K.

PY - 2009/7/21

Y1 - 2009/7/21

N2 - A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.

AB - A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.

KW - Beam diagnostics

KW - Delay-line detector

KW - Ion optics

KW - Penning trap mass spectrometry

KW - Position-sensitive ion detection

KW - TOF-ICR

UR - http://www.scopus.com/inward/record.url?scp=67649425333&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67649425333&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2009.04.046

DO - 10.1016/j.nima.2009.04.046

M3 - Article

AN - SCOPUS:67649425333

VL - 606

SP - 475

EP - 483

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 3

ER -