Introduction: A considerable proportion of laboratory errors occurs in the preanalytical phase. Aim: The aims of the authors were to study preanalytical errors in routine and emergency laboratory diagnostics in a regional clinical laboratory and evaluate the effect of the pneumatic tube system on turnaround time and laboratory results. Method: The ratio of preanalytical errors and reasons of test rejection were analysed. In addition, the effects of pneumatic tube and manual transport on the occurrence of hemolysis and platelet activation were compared. Results: Using the pneumatic tube transport system, preanalytical error was below 1%. The main causes of test rejection were haemolysis in case of serum samples, and clot formation and citrate excess in anticoagulated samples. The pneumatic tube transport resulted in significantly faster sample transport, more equalized sample arrival and processing, hence the turnaround time became shorter both for routine and emergency tests. Conclusions: Autovalidation and proper control of preanalytical errors are essential for rapid and reliable laboratory service supported by the pneumatic tube system for sample transport.

Original languageHungarian
Pages (from-to)1113-1120
Number of pages8
JournalOrvosi Hetilap
Volume155
Issue number28
DOIs
Publication statusPublished - Jul 1 2014

Fingerprint

Hemolysis
Emergencies
Platelet Activation
Citric Acid
Serum

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Tóth, J., Lenkey, Á., Oláh, A. V., Köteles, J., Kissné Sziráki, V., Kerényi, A., & Kappelmayer, J. (2014). Preanalitikai szempontok pneumatikus csopostával szállított laboratóriumi minták esetén. Orvosi Hetilap, 155(28), 1113-1120. https://doi.org/10.1556/OH.2014.29895

Preanalitikai szempontok pneumatikus csopostával szállított laboratóriumi minták esetén. / Tóth, Judit; Lenkey, Ágota; Oláh, Anna V.; Köteles, Julianna; Kissné Sziráki, Valéria; Kerényi, Adrienne; Kappelmayer, J.

In: Orvosi Hetilap, Vol. 155, No. 28, 01.07.2014, p. 1113-1120.

Research output: Contribution to journalArticle

Tóth, J, Lenkey, Á, Oláh, AV, Köteles, J, Kissné Sziráki, V, Kerényi, A & Kappelmayer, J 2014, 'Preanalitikai szempontok pneumatikus csopostával szállított laboratóriumi minták esetén', Orvosi Hetilap, vol. 155, no. 28, pp. 1113-1120. https://doi.org/10.1556/OH.2014.29895
Tóth J, Lenkey Á, Oláh AV, Köteles J, Kissné Sziráki V, Kerényi A et al. Preanalitikai szempontok pneumatikus csopostával szállított laboratóriumi minták esetén. Orvosi Hetilap. 2014 Jul 1;155(28):1113-1120. https://doi.org/10.1556/OH.2014.29895
Tóth, Judit ; Lenkey, Ágota ; Oláh, Anna V. ; Köteles, Julianna ; Kissné Sziráki, Valéria ; Kerényi, Adrienne ; Kappelmayer, J. / Preanalitikai szempontok pneumatikus csopostával szállított laboratóriumi minták esetén. In: Orvosi Hetilap. 2014 ; Vol. 155, No. 28. pp. 1113-1120.
@article{e9c9f43e80bf43e4bbf6d4346da0f31b,
title = "Preanalitikai szempontok pneumatikus csopost{\'a}val sz{\'a}ll{\'i}tott laborat{\'o}riumi mint{\'a}k eset{\'e}n",
abstract = "Introduction: A considerable proportion of laboratory errors occurs in the preanalytical phase. Aim: The aims of the authors were to study preanalytical errors in routine and emergency laboratory diagnostics in a regional clinical laboratory and evaluate the effect of the pneumatic tube system on turnaround time and laboratory results. Method: The ratio of preanalytical errors and reasons of test rejection were analysed. In addition, the effects of pneumatic tube and manual transport on the occurrence of hemolysis and platelet activation were compared. Results: Using the pneumatic tube transport system, preanalytical error was below 1{\%}. The main causes of test rejection were haemolysis in case of serum samples, and clot formation and citrate excess in anticoagulated samples. The pneumatic tube transport resulted in significantly faster sample transport, more equalized sample arrival and processing, hence the turnaround time became shorter both for routine and emergency tests. Conclusions: Autovalidation and proper control of preanalytical errors are essential for rapid and reliable laboratory service supported by the pneumatic tube system for sample transport.",
keywords = "hemolysis, laboratory diagnostics, pneumatic tube system, preanalytical errors, turnaround time",
author = "Judit T{\'o}th and {\'A}gota Lenkey and Ol{\'a}h, {Anna V.} and Julianna K{\"o}teles and {Kissn{\'e} Szir{\'a}ki}, Val{\'e}ria and Adrienne Ker{\'e}nyi and J. Kappelmayer",
year = "2014",
month = "7",
day = "1",
doi = "10.1556/OH.2014.29895",
language = "Hungarian",
volume = "155",
pages = "1113--1120",
journal = "Orvosi Hetilap",
issn = "0030-6002",
publisher = "Akademiai Kiado",
number = "28",

}

TY - JOUR

T1 - Preanalitikai szempontok pneumatikus csopostával szállított laboratóriumi minták esetén

AU - Tóth, Judit

AU - Lenkey, Ágota

AU - Oláh, Anna V.

AU - Köteles, Julianna

AU - Kissné Sziráki, Valéria

AU - Kerényi, Adrienne

AU - Kappelmayer, J.

PY - 2014/7/1

Y1 - 2014/7/1

N2 - Introduction: A considerable proportion of laboratory errors occurs in the preanalytical phase. Aim: The aims of the authors were to study preanalytical errors in routine and emergency laboratory diagnostics in a regional clinical laboratory and evaluate the effect of the pneumatic tube system on turnaround time and laboratory results. Method: The ratio of preanalytical errors and reasons of test rejection were analysed. In addition, the effects of pneumatic tube and manual transport on the occurrence of hemolysis and platelet activation were compared. Results: Using the pneumatic tube transport system, preanalytical error was below 1%. The main causes of test rejection were haemolysis in case of serum samples, and clot formation and citrate excess in anticoagulated samples. The pneumatic tube transport resulted in significantly faster sample transport, more equalized sample arrival and processing, hence the turnaround time became shorter both for routine and emergency tests. Conclusions: Autovalidation and proper control of preanalytical errors are essential for rapid and reliable laboratory service supported by the pneumatic tube system for sample transport.

AB - Introduction: A considerable proportion of laboratory errors occurs in the preanalytical phase. Aim: The aims of the authors were to study preanalytical errors in routine and emergency laboratory diagnostics in a regional clinical laboratory and evaluate the effect of the pneumatic tube system on turnaround time and laboratory results. Method: The ratio of preanalytical errors and reasons of test rejection were analysed. In addition, the effects of pneumatic tube and manual transport on the occurrence of hemolysis and platelet activation were compared. Results: Using the pneumatic tube transport system, preanalytical error was below 1%. The main causes of test rejection were haemolysis in case of serum samples, and clot formation and citrate excess in anticoagulated samples. The pneumatic tube transport resulted in significantly faster sample transport, more equalized sample arrival and processing, hence the turnaround time became shorter both for routine and emergency tests. Conclusions: Autovalidation and proper control of preanalytical errors are essential for rapid and reliable laboratory service supported by the pneumatic tube system for sample transport.

KW - hemolysis

KW - laboratory diagnostics

KW - pneumatic tube system

KW - preanalytical errors

KW - turnaround time

UR - http://www.scopus.com/inward/record.url?scp=84904130773&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904130773&partnerID=8YFLogxK

U2 - 10.1556/OH.2014.29895

DO - 10.1556/OH.2014.29895

M3 - Article

C2 - 25002315

AN - SCOPUS:84904130773

VL - 155

SP - 1113

EP - 1120

JO - Orvosi Hetilap

JF - Orvosi Hetilap

SN - 0030-6002

IS - 28

ER -