Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor

V. Aksenov, A. M. Balagurov, V. G. Simkin, A. P. Bulkin, V. A. Kudryashev, V. A. Trounov, O. Antson, R. Hiismäki, A. Tiitta

Research output: Contribution to journalArticle

38 Citations (Scopus)

Abstract

The first neutron Fourier diffractometer at the pulsed neutron source, the High Resolution Fourier Diffractometer (HRFD), is described. The HRFD combines both high neutron flux at the sample position, ~ 107n/cm2/s, provided by the IBR-2 nigh flux pulsed reactor, and high resolution, very close to 0.001, over a wide range of d-spacings. The paper deals with the basic principles of HRFD, its design, and performance. Examples of structural experiments are also given.

Original languageEnglish
Pages (from-to)181-200
Number of pages20
JournalJournal of Neutron Research
Volume5
Issue number4
DOIs
Publication statusPublished - 1997

Fingerprint

Diffractometers
diffractometers
reactors
high resolution
Neutron flux
Neutron sources
neutron sources
flux (rate)
Neutrons
spacing
Fluxes
neutrons
Experiments

Keywords

  • High resolution
  • Neutron fourier diffractometer
  • Powder diffraction
  • Pulsed neutron source

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering

Cite this

Aksenov, V., Balagurov, A. M., Simkin, V. G., Bulkin, A. P., Kudryashev, V. A., Trounov, V. A., ... Tiitta, A. (1997). Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor. Journal of Neutron Research, 5(4), 181-200. https://doi.org/10.1080/10238169708200223

Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor. / Aksenov, V.; Balagurov, A. M.; Simkin, V. G.; Bulkin, A. P.; Kudryashev, V. A.; Trounov, V. A.; Antson, O.; Hiismäki, R.; Tiitta, A.

In: Journal of Neutron Research, Vol. 5, No. 4, 1997, p. 181-200.

Research output: Contribution to journalArticle

Aksenov, V, Balagurov, AM, Simkin, VG, Bulkin, AP, Kudryashev, VA, Trounov, VA, Antson, O, Hiismäki, R & Tiitta, A 1997, 'Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor', Journal of Neutron Research, vol. 5, no. 4, pp. 181-200. https://doi.org/10.1080/10238169708200223
Aksenov, V. ; Balagurov, A. M. ; Simkin, V. G. ; Bulkin, A. P. ; Kudryashev, V. A. ; Trounov, V. A. ; Antson, O. ; Hiismäki, R. ; Tiitta, A. / Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor. In: Journal of Neutron Research. 1997 ; Vol. 5, No. 4. pp. 181-200.
@article{f4e0823f14e64693973be2f629b30e60,
title = "Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor",
abstract = "The first neutron Fourier diffractometer at the pulsed neutron source, the High Resolution Fourier Diffractometer (HRFD), is described. The HRFD combines both high neutron flux at the sample position, ~ 107n/cm2/s, provided by the IBR-2 nigh flux pulsed reactor, and high resolution, very close to 0.001, over a wide range of d-spacings. The paper deals with the basic principles of HRFD, its design, and performance. Examples of structural experiments are also given.",
keywords = "High resolution, Neutron fourier diffractometer, Powder diffraction, Pulsed neutron source",
author = "V. Aksenov and Balagurov, {A. M.} and Simkin, {V. G.} and Bulkin, {A. P.} and Kudryashev, {V. A.} and Trounov, {V. A.} and O. Antson and R. Hiism{\"a}ki and A. Tiitta",
year = "1997",
doi = "10.1080/10238169708200223",
language = "English",
volume = "5",
pages = "181--200",
journal = "Journal of Neutron Research",
issn = "1023-8166",
publisher = "IOS Press",
number = "4",

}

TY - JOUR

T1 - Performance of the high resolution fourier diffractometer at the IBR-2 pulsed reactor

AU - Aksenov, V.

AU - Balagurov, A. M.

AU - Simkin, V. G.

AU - Bulkin, A. P.

AU - Kudryashev, V. A.

AU - Trounov, V. A.

AU - Antson, O.

AU - Hiismäki, R.

AU - Tiitta, A.

PY - 1997

Y1 - 1997

N2 - The first neutron Fourier diffractometer at the pulsed neutron source, the High Resolution Fourier Diffractometer (HRFD), is described. The HRFD combines both high neutron flux at the sample position, ~ 107n/cm2/s, provided by the IBR-2 nigh flux pulsed reactor, and high resolution, very close to 0.001, over a wide range of d-spacings. The paper deals with the basic principles of HRFD, its design, and performance. Examples of structural experiments are also given.

AB - The first neutron Fourier diffractometer at the pulsed neutron source, the High Resolution Fourier Diffractometer (HRFD), is described. The HRFD combines both high neutron flux at the sample position, ~ 107n/cm2/s, provided by the IBR-2 nigh flux pulsed reactor, and high resolution, very close to 0.001, over a wide range of d-spacings. The paper deals with the basic principles of HRFD, its design, and performance. Examples of structural experiments are also given.

KW - High resolution

KW - Neutron fourier diffractometer

KW - Powder diffraction

KW - Pulsed neutron source

UR - http://www.scopus.com/inward/record.url?scp=85013577437&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85013577437&partnerID=8YFLogxK

U2 - 10.1080/10238169708200223

DO - 10.1080/10238169708200223

M3 - Article

AN - SCOPUS:85013577437

VL - 5

SP - 181

EP - 200

JO - Journal of Neutron Research

JF - Journal of Neutron Research

SN - 1023-8166

IS - 4

ER -