Percutan transhepaticus fémstent behelyezésével kezelt májkapuvéna-szu″kületek májátü ltetés után

Translated title of the contribution: Percutaneous transhepatic metallic stent placement for the treatment of post-transplantation portal vein stenosis

Attila Doros, Balázs Nemes, Imre Fehérvári, Dénes Görög, Zsuzsa Gerlei, Andrea Németh, Erika Hartmann, Pál Deák, János Fazakas, Szabolcs Tóth, László Kóbori

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Liver transplantation is a routinely used therapeutic choice in the treatment of end stage liver disease. Portal vein stenosis is a rare vascular complication after liver transplantation. We report the interventional radiological management of three cases of portal vein stenosis. Aim: The surgical management of portal vein stenosis can be hazardous for the patient and the transplanted liver in the early post-transplantation period. In general, interventional radiological methods are tolerable for patients and can be safely performed with high success rate. The aim of this report is to analyze the feasibility, the risks and the efficacy of the percutaneous transhepatic self expanding metallic stent placement into the portal vein. Method: Three of the 396 liver transplantations cases in Budapest developed significant portal vein stenosis. In these cases, ultrasound guided percutaneous transhepatic portal vein puncture with fine needle was performed. The tract was dilated with a coaxial dilator set, and an adequately sized sheath introducer was inserted into the liver parenchyma. Two nitinol and one stainless steel self expanding metallic stent were implanted at the stenotic portal vein anastomoses. The tract was embolized with gelfoam particles (1 case), or coils (1case). In the third patient no tract embolization was performed. Result: All treatments were technically successful, without minor or major complications. In two cases the amount of free abdominal fluid decreased significantly, and in the third case the esophageal varicosity regressed. The morphological success was documented with ultrasound and computed tomography examination. Two patients are alive and well after 10 and 39 months of follow up, while the third patient died after one month in multi organ failure. Conclusion: Percutaneous transhepatic metallic stent placement for the treatment of post-transplantation portal vein stenosis is a safe and effective method.

Translated title of the contributionPercutaneous transhepatic metallic stent placement for the treatment of post-transplantation portal vein stenosis
Original languageHungarian
Pages (from-to)1231-1234
Number of pages4
JournalOrvosi hetilap
Volume150
Issue number26
DOIs
Publication statusPublished - Jun 1 2009

ASJC Scopus subject areas

  • Medicine(all)

Fingerprint Dive into the research topics of 'Percutaneous transhepatic metallic stent placement for the treatment of post-transplantation portal vein stenosis'. Together they form a unique fingerprint.

  • Cite this

    Doros, A., Nemes, B., Fehérvári, I., Görög, D., Gerlei, Z., Németh, A., Hartmann, E., Deák, P., Fazakas, J., Tóth, S., & Kóbori, L. (2009). Percutan transhepaticus fémstent behelyezésével kezelt májkapuvéna-szu″kületek májátü ltetés után. Orvosi hetilap, 150(26), 1231-1234. https://doi.org/10.1556/OH.2009.28607