A modern construction peak selector based on digital techniques has been constructed. The instrument can be extended to a maximum of nine signal channels selecting the ion-current with the help of thumbwheel switches. In the first channel it is possible to set the full mass range, while in each of the other eight channels a width of a maximum of nine atomic mass units can be set. The instrument has got a mass identifier circuit and optionally each channel has a fast analog signal processing unit. The peak selector can be coupled to any kind of quadrupole mass spectrometer with a maximum mass range up to 512 amu.

Original languageEnglish
Pages (from-to)87-88
Number of pages2
JournalVacuum
Volume33
Issue number1-2
DOIs
Publication statusPublished - 1983

Fingerprint

selectors
Mass spectrometers
mass spectrometers
quadrupoles
Signal processing
Switches
Ions
digital techniques
atomic weights
Networks (circuits)
ion currents
signal processing
switches
analogs

ASJC Scopus subject areas

  • Surfaces, Coatings and Films
  • Condensed Matter Physics
  • Surfaces and Interfaces

Cite this

Peak selector for quadrupole mass spectrometer. / Berecz, I.; Bohátka, S.; Diós, Z.; Langer, G.

In: Vacuum, Vol. 33, No. 1-2, 1983, p. 87-88.

Research output: Contribution to journalArticle

Berecz, I, Bohátka, S, Diós, Z & Langer, G 1983, 'Peak selector for quadrupole mass spectrometer', Vacuum, vol. 33, no. 1-2, pp. 87-88. https://doi.org/10.1016/0042-207X(83)90536-5
Berecz, I. ; Bohátka, S. ; Diós, Z. ; Langer, G. / Peak selector for quadrupole mass spectrometer. In: Vacuum. 1983 ; Vol. 33, No. 1-2. pp. 87-88.
@article{a11a919077244cadbbce2f868264bc5b,
title = "Peak selector for quadrupole mass spectrometer",
abstract = "A modern construction peak selector based on digital techniques has been constructed. The instrument can be extended to a maximum of nine signal channels selecting the ion-current with the help of thumbwheel switches. In the first channel it is possible to set the full mass range, while in each of the other eight channels a width of a maximum of nine atomic mass units can be set. The instrument has got a mass identifier circuit and optionally each channel has a fast analog signal processing unit. The peak selector can be coupled to any kind of quadrupole mass spectrometer with a maximum mass range up to 512 amu.",
author = "I. Berecz and S. Boh{\'a}tka and Z. Di{\'o}s and G. Langer",
year = "1983",
doi = "10.1016/0042-207X(83)90536-5",
language = "English",
volume = "33",
pages = "87--88",
journal = "Vacuum",
issn = "0042-207X",
publisher = "Elsevier Limited",
number = "1-2",

}

TY - JOUR

T1 - Peak selector for quadrupole mass spectrometer

AU - Berecz, I.

AU - Bohátka, S.

AU - Diós, Z.

AU - Langer, G.

PY - 1983

Y1 - 1983

N2 - A modern construction peak selector based on digital techniques has been constructed. The instrument can be extended to a maximum of nine signal channels selecting the ion-current with the help of thumbwheel switches. In the first channel it is possible to set the full mass range, while in each of the other eight channels a width of a maximum of nine atomic mass units can be set. The instrument has got a mass identifier circuit and optionally each channel has a fast analog signal processing unit. The peak selector can be coupled to any kind of quadrupole mass spectrometer with a maximum mass range up to 512 amu.

AB - A modern construction peak selector based on digital techniques has been constructed. The instrument can be extended to a maximum of nine signal channels selecting the ion-current with the help of thumbwheel switches. In the first channel it is possible to set the full mass range, while in each of the other eight channels a width of a maximum of nine atomic mass units can be set. The instrument has got a mass identifier circuit and optionally each channel has a fast analog signal processing unit. The peak selector can be coupled to any kind of quadrupole mass spectrometer with a maximum mass range up to 512 amu.

UR - http://www.scopus.com/inward/record.url?scp=0019344558&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019344558&partnerID=8YFLogxK

U2 - 10.1016/0042-207X(83)90536-5

DO - 10.1016/0042-207X(83)90536-5

M3 - Article

VL - 33

SP - 87

EP - 88

JO - Vacuum

JF - Vacuum

SN - 0042-207X

IS - 1-2

ER -