Oxygen and carbon dioxide tensions in calf muscles of rat

L. Józsa, A. Reffy, S. Demel, I. Szilagyi

Research output: Contribution to journalArticle

Abstract

The oxygen and carbon dioxide tension were studied with the Silastic tonometer technique in skeletal muscle and subcutaneous tissue of rat. The high initial pO2 was caused by airborne contamination during implantation and declined rapidly. Tissue gas tensions measured with a Silastic tonometer reflect the healing sequences of implantation trauma and stable readings are not obtained until 14 days after implantation. After healing of implantation injury 42 to 47 mmHg pO2 and 50 to 57 mmHg pCO2 were measured in muscle and 23 to 26 mmHg pO2 and 51 to 57 mmHg pCO2 in subcutaneous tissue of rat.

Original languageEnglish
Pages (from-to)86-90
Number of pages5
JournalZeitschrift fur Experimentelle Chirurgie
Volume13
Issue number2
Publication statusPublished - 1980

Fingerprint

Subcutaneous Tissue
Carbon Dioxide
Oxygen
Muscles
Wounds and Injuries
Reading
Skeletal Muscle
Gases
baysilon

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Oxygen and carbon dioxide tensions in calf muscles of rat. / Józsa, L.; Reffy, A.; Demel, S.; Szilagyi, I.

In: Zeitschrift fur Experimentelle Chirurgie, Vol. 13, No. 2, 1980, p. 86-90.

Research output: Contribution to journalArticle

Józsa, L, Reffy, A, Demel, S & Szilagyi, I 1980, 'Oxygen and carbon dioxide tensions in calf muscles of rat', Zeitschrift fur Experimentelle Chirurgie, vol. 13, no. 2, pp. 86-90.
Józsa, L. ; Reffy, A. ; Demel, S. ; Szilagyi, I. / Oxygen and carbon dioxide tensions in calf muscles of rat. In: Zeitschrift fur Experimentelle Chirurgie. 1980 ; Vol. 13, No. 2. pp. 86-90.
@article{2cad5b806d844b5d92261d24cd7f3185,
title = "Oxygen and carbon dioxide tensions in calf muscles of rat",
abstract = "The oxygen and carbon dioxide tension were studied with the Silastic tonometer technique in skeletal muscle and subcutaneous tissue of rat. The high initial pO2 was caused by airborne contamination during implantation and declined rapidly. Tissue gas tensions measured with a Silastic tonometer reflect the healing sequences of implantation trauma and stable readings are not obtained until 14 days after implantation. After healing of implantation injury 42 to 47 mmHg pO2 and 50 to 57 mmHg pCO2 were measured in muscle and 23 to 26 mmHg pO2 and 51 to 57 mmHg pCO2 in subcutaneous tissue of rat.",
author = "L. J{\'o}zsa and A. Reffy and S. Demel and I. Szilagyi",
year = "1980",
language = "English",
volume = "13",
pages = "86--90",
journal = "Zeitschrift fur Experimentelle Chirurgie",
issn = "0323-5580",
publisher = "Berlin Verlag Volk Und Gesundheit",
number = "2",

}

TY - JOUR

T1 - Oxygen and carbon dioxide tensions in calf muscles of rat

AU - Józsa, L.

AU - Reffy, A.

AU - Demel, S.

AU - Szilagyi, I.

PY - 1980

Y1 - 1980

N2 - The oxygen and carbon dioxide tension were studied with the Silastic tonometer technique in skeletal muscle and subcutaneous tissue of rat. The high initial pO2 was caused by airborne contamination during implantation and declined rapidly. Tissue gas tensions measured with a Silastic tonometer reflect the healing sequences of implantation trauma and stable readings are not obtained until 14 days after implantation. After healing of implantation injury 42 to 47 mmHg pO2 and 50 to 57 mmHg pCO2 were measured in muscle and 23 to 26 mmHg pO2 and 51 to 57 mmHg pCO2 in subcutaneous tissue of rat.

AB - The oxygen and carbon dioxide tension were studied with the Silastic tonometer technique in skeletal muscle and subcutaneous tissue of rat. The high initial pO2 was caused by airborne contamination during implantation and declined rapidly. Tissue gas tensions measured with a Silastic tonometer reflect the healing sequences of implantation trauma and stable readings are not obtained until 14 days after implantation. After healing of implantation injury 42 to 47 mmHg pO2 and 50 to 57 mmHg pCO2 were measured in muscle and 23 to 26 mmHg pO2 and 51 to 57 mmHg pCO2 in subcutaneous tissue of rat.

UR - http://www.scopus.com/inward/record.url?scp=0018855706&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018855706&partnerID=8YFLogxK

M3 - Article

C2 - 6778002

AN - SCOPUS:0018855706

VL - 13

SP - 86

EP - 90

JO - Zeitschrift fur Experimentelle Chirurgie

JF - Zeitschrift fur Experimentelle Chirurgie

SN - 0323-5580

IS - 2

ER -