Multifunctional synchrotron spectrometer of the National Research Center “Kurchatov Institute”: I. EXAFS in dispersive mode

V. Aksenov, S. I. Tyutyunnikov, V. N. Shalyapin, A. D. Belyaev, A. N. Artemiev, N. A. Artemiev, B. F. Kirillov, M. V. Kovalchiuk, A. A. Demkiv, G. A. Knyazev

Research output: Contribution to journalArticle

Abstract

The improved X-ray optical scheme, the system of registration, and the measurement procedure of the multifunctional synchrotron radiation spectrometer in the dispersive EXAFS mode are described. The results of the spectrometer energy resolution measurements are given. The advantages and disadvantages of traditional and dispersive EXAFS spectrometers are analyzed. Examples of EXAFS spectra measured in the dispersive mode are given.

Original languageEnglish
Pages (from-to)123-131
Number of pages9
JournalPhysics of Particles and Nuclei Letters
Volume14
Issue number1
DOIs
Publication statusPublished - Jan 1 2017

Fingerprint

Optical Devices
Synchrotrons
synchrotrons
X-Rays
spectrometers
Radiation
Research
synchrotron radiation
x rays
energy

Keywords

  • dispersive EXAFS spectrometer
  • synchrotron radiation
  • X-ray spectrometer

ASJC Scopus subject areas

  • Radiation
  • Atomic and Molecular Physics, and Optics
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Cite this

Multifunctional synchrotron spectrometer of the National Research Center “Kurchatov Institute” : I. EXAFS in dispersive mode. / Aksenov, V.; Tyutyunnikov, S. I.; Shalyapin, V. N.; Belyaev, A. D.; Artemiev, A. N.; Artemiev, N. A.; Kirillov, B. F.; Kovalchiuk, M. V.; Demkiv, A. A.; Knyazev, G. A.

In: Physics of Particles and Nuclei Letters, Vol. 14, No. 1, 01.01.2017, p. 123-131.

Research output: Contribution to journalArticle

Aksenov, V, Tyutyunnikov, SI, Shalyapin, VN, Belyaev, AD, Artemiev, AN, Artemiev, NA, Kirillov, BF, Kovalchiuk, MV, Demkiv, AA & Knyazev, GA 2017, 'Multifunctional synchrotron spectrometer of the National Research Center “Kurchatov Institute”: I. EXAFS in dispersive mode', Physics of Particles and Nuclei Letters, vol. 14, no. 1, pp. 123-131. https://doi.org/10.1134/S1547477117010022
Aksenov, V. ; Tyutyunnikov, S. I. ; Shalyapin, V. N. ; Belyaev, A. D. ; Artemiev, A. N. ; Artemiev, N. A. ; Kirillov, B. F. ; Kovalchiuk, M. V. ; Demkiv, A. A. ; Knyazev, G. A. / Multifunctional synchrotron spectrometer of the National Research Center “Kurchatov Institute” : I. EXAFS in dispersive mode. In: Physics of Particles and Nuclei Letters. 2017 ; Vol. 14, No. 1. pp. 123-131.
@article{07d23783735e4cc6b5feaa0bda51fb5b,
title = "Multifunctional synchrotron spectrometer of the National Research Center “Kurchatov Institute”: I. EXAFS in dispersive mode",
abstract = "The improved X-ray optical scheme, the system of registration, and the measurement procedure of the multifunctional synchrotron radiation spectrometer in the dispersive EXAFS mode are described. The results of the spectrometer energy resolution measurements are given. The advantages and disadvantages of traditional and dispersive EXAFS spectrometers are analyzed. Examples of EXAFS spectra measured in the dispersive mode are given.",
keywords = "dispersive EXAFS spectrometer, synchrotron radiation, X-ray spectrometer",
author = "V. Aksenov and Tyutyunnikov, {S. I.} and Shalyapin, {V. N.} and Belyaev, {A. D.} and Artemiev, {A. N.} and Artemiev, {N. A.} and Kirillov, {B. F.} and Kovalchiuk, {M. V.} and Demkiv, {A. A.} and Knyazev, {G. A.}",
year = "2017",
month = "1",
day = "1",
doi = "10.1134/S1547477117010022",
language = "English",
volume = "14",
pages = "123--131",
journal = "Physics of Particles and Nuclei Letters",
issn = "1547-4771",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "1",

}

TY - JOUR

T1 - Multifunctional synchrotron spectrometer of the National Research Center “Kurchatov Institute”

T2 - I. EXAFS in dispersive mode

AU - Aksenov, V.

AU - Tyutyunnikov, S. I.

AU - Shalyapin, V. N.

AU - Belyaev, A. D.

AU - Artemiev, A. N.

AU - Artemiev, N. A.

AU - Kirillov, B. F.

AU - Kovalchiuk, M. V.

AU - Demkiv, A. A.

AU - Knyazev, G. A.

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The improved X-ray optical scheme, the system of registration, and the measurement procedure of the multifunctional synchrotron radiation spectrometer in the dispersive EXAFS mode are described. The results of the spectrometer energy resolution measurements are given. The advantages and disadvantages of traditional and dispersive EXAFS spectrometers are analyzed. Examples of EXAFS spectra measured in the dispersive mode are given.

AB - The improved X-ray optical scheme, the system of registration, and the measurement procedure of the multifunctional synchrotron radiation spectrometer in the dispersive EXAFS mode are described. The results of the spectrometer energy resolution measurements are given. The advantages and disadvantages of traditional and dispersive EXAFS spectrometers are analyzed. Examples of EXAFS spectra measured in the dispersive mode are given.

KW - dispersive EXAFS spectrometer

KW - synchrotron radiation

KW - X-ray spectrometer

UR - http://www.scopus.com/inward/record.url?scp=85013137943&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85013137943&partnerID=8YFLogxK

U2 - 10.1134/S1547477117010022

DO - 10.1134/S1547477117010022

M3 - Article

AN - SCOPUS:85013137943

VL - 14

SP - 123

EP - 131

JO - Physics of Particles and Nuclei Letters

JF - Physics of Particles and Nuclei Letters

SN - 1547-4771

IS - 1

ER -