Abstract
This document describes results obtained from the Link alignment system data recorded during the Compact Muon Solenoid (CMS) Magnet Test. A brief description of the system is followed by a discussion of the detected relative displacements (from micrometres to centimetres) between detector elements and rotations of detector structures (from microradians to milliradians). Observed displacements are studied as functions of the magnetic field intensity. In addition, the reconstructed positions of active element sensors are compared to their positions as measured by photogrammetry and the reconstructed motions due to the magnetic field strength are described.
Original language | English |
---|---|
Pages (from-to) | 344-361 |
Number of pages | 18 |
Journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
Volume | 606 |
Issue number | 3 |
DOIs | |
Publication status | Published - Jul 21 2009 |
Fingerprint
Keywords
- Alignment
- CMS
- Detectors
ASJC Scopus subject areas
- Instrumentation
- Nuclear and High Energy Physics
Cite this
Motions of CMS detector structures due to the magnetic field forces as observed by the Link alignment system during the test of the 4 T magnet solenoid. / García-Moral, L. A.; Gómez, G.; González-Sánchez, F. J.; Martínez-Rivero, C.; Matorras, F.; Rodrigo, T.; Martínez, P.; Scodellaro, L.; Vila, I.; Virto, A. L.; Sobrón, M.; Alberdi, J.; Arce, P.; Barcala, J. M.; Calvo, E.; Ferrando, A.; Josa, M. I.; Molinero, A.; Navarrete, J.; Oller, J. C.; Yuste, C.; Béni, N.; Raics, P.; Szabó, Zs; Trócsányi, Z.; Újvári, B.; Zilizi, G.; Christian, G.; Imrek, J.; Molnár, J.; Novák, D.; Pálinkás, J.; Székely, G.; Szillási, Z.; Bencze, G.; Vesztergombi, G.; Calderón, A.; Benettoni, M.; Gasparini, F.; Montecassiano, F.; Rampazzo, M.; Zago, M.; Benvenuti, A.
In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 606, No. 3, 21.07.2009, p. 344-361.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Motions of CMS detector structures due to the magnetic field forces as observed by the Link alignment system during the test of the 4 T magnet solenoid
AU - García-Moral, L. A.
AU - Gómez, G.
AU - González-Sánchez, F. J.
AU - Martínez-Rivero, C.
AU - Matorras, F.
AU - Rodrigo, T.
AU - Martínez, P.
AU - Scodellaro, L.
AU - Vila, I.
AU - Virto, A. L.
AU - Sobrón, M.
AU - Alberdi, J.
AU - Arce, P.
AU - Barcala, J. M.
AU - Calvo, E.
AU - Ferrando, A.
AU - Josa, M. I.
AU - Molinero, A.
AU - Navarrete, J.
AU - Oller, J. C.
AU - Yuste, C.
AU - Béni, N.
AU - Raics, P.
AU - Szabó, Zs
AU - Trócsányi, Z.
AU - Újvári, B.
AU - Zilizi, G.
AU - Christian, G.
AU - Imrek, J.
AU - Molnár, J.
AU - Novák, D.
AU - Pálinkás, J.
AU - Székely, G.
AU - Szillási, Z.
AU - Bencze, G.
AU - Vesztergombi, G.
AU - Calderón, A.
AU - Benettoni, M.
AU - Gasparini, F.
AU - Montecassiano, F.
AU - Rampazzo, M.
AU - Zago, M.
AU - Benvenuti, A.
PY - 2009/7/21
Y1 - 2009/7/21
N2 - This document describes results obtained from the Link alignment system data recorded during the Compact Muon Solenoid (CMS) Magnet Test. A brief description of the system is followed by a discussion of the detected relative displacements (from micrometres to centimetres) between detector elements and rotations of detector structures (from microradians to milliradians). Observed displacements are studied as functions of the magnetic field intensity. In addition, the reconstructed positions of active element sensors are compared to their positions as measured by photogrammetry and the reconstructed motions due to the magnetic field strength are described.
AB - This document describes results obtained from the Link alignment system data recorded during the Compact Muon Solenoid (CMS) Magnet Test. A brief description of the system is followed by a discussion of the detected relative displacements (from micrometres to centimetres) between detector elements and rotations of detector structures (from microradians to milliradians). Observed displacements are studied as functions of the magnetic field intensity. In addition, the reconstructed positions of active element sensors are compared to their positions as measured by photogrammetry and the reconstructed motions due to the magnetic field strength are described.
KW - Alignment
KW - CMS
KW - Detectors
UR - http://www.scopus.com/inward/record.url?scp=67649450048&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67649450048&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2009.03.252
DO - 10.1016/j.nima.2009.03.252
M3 - Article
AN - SCOPUS:67649450048
VL - 606
SP - 344
EP - 361
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
IS - 3
ER -