Method for validating CT length measurement of cracks inside solder joints

Tamás Garami, Oliver Krammer, G. Harsányi, Péter Martinek

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Purpose - This paper aims to develop a method to measure the length of cracks inside solder joints, which enables the validation of computed tomography (CT) crack length measurements. Design/methodology/approach - Cracks were formed inside solder joints intentionally by aging solder joints of 0603 size resistors with thermal shock (TS) test (-40 to -140°C, 2,000 cycles), and CT images were captured about them with different rotational increment (1/4, 1/2 and 1°) of sample projection. The length of cracks was also measured with our method, which is based on capturing high-resolution radiography X-ray images about the cracks in two perpendicular projection planes. The radiography results were compared to the CT measurements. The percentage error for the different CT rotational increment settings was calculated, and the optimal CT settings have been determined. Findings - The results have proven that reducing the rotational increment increases the sharpness of the captured images and the accuracy of crack length measurements. Nevertheless, the accuracy compared to high-resolution radiography measurements is only slightly better at 1/4° rotational increment than in the case of 1/2° rotational increment. It should be also noted that the 1/4° increment requires twice as much time for capturing the images as the 1/2° increment. So, the 1/2° rotational increment of sample projection is the optimal setting in our investigated case for measuring crack lengths. Practical implications - The developed method is applicable to find the optimal settings for CT crack length measurements, which provides faster analysation of large quantity samples used, e.g. at life-time tests. Originality/value - There is a lack of information in the literature regarding the optimisation of CT measurement set-up, e.g. a slightly larger value of the sample rotational increment can provide acceptable resolution with much faster processing time. Thus, the authors developed a method and performed research about optimising CT measurement parameters.

Original languageEnglish
Pages (from-to)13-17
Number of pages5
JournalSoldering and Surface Mount Technology
Volume28
Issue number1
DOIs
Publication statusPublished - Feb 1 2016

Fingerprint

solders
Soldering alloys
Tomography
cracks
tomography
Cracks
radiography
projection
Radiography
shock tests
X ray radiography
thermal shock
high resolution
sharpness
Thermal shock
resistors
Resistors
Aging of materials
methodology
life (durability)

Keywords

  • Computed tomography
  • Interfacial cracking
  • Pb-free
  • Thermal shock test
  • Vapour phase soldering
  • X-ray imaging

ASJC Scopus subject areas

  • Materials Science(all)
  • Condensed Matter Physics
  • Electrical and Electronic Engineering

Cite this

Method for validating CT length measurement of cracks inside solder joints. / Garami, Tamás; Krammer, Oliver; Harsányi, G.; Martinek, Péter.

In: Soldering and Surface Mount Technology, Vol. 28, No. 1, 01.02.2016, p. 13-17.

Research output: Contribution to journalArticle

Garami, Tamás ; Krammer, Oliver ; Harsányi, G. ; Martinek, Péter. / Method for validating CT length measurement of cracks inside solder joints. In: Soldering and Surface Mount Technology. 2016 ; Vol. 28, No. 1. pp. 13-17.
@article{c2228795d64b46b59afaf8dd4411cce2,
title = "Method for validating CT length measurement of cracks inside solder joints",
abstract = "Purpose - This paper aims to develop a method to measure the length of cracks inside solder joints, which enables the validation of computed tomography (CT) crack length measurements. Design/methodology/approach - Cracks were formed inside solder joints intentionally by aging solder joints of 0603 size resistors with thermal shock (TS) test (-40 to -140°C, 2,000 cycles), and CT images were captured about them with different rotational increment (1/4, 1/2 and 1°) of sample projection. The length of cracks was also measured with our method, which is based on capturing high-resolution radiography X-ray images about the cracks in two perpendicular projection planes. The radiography results were compared to the CT measurements. The percentage error for the different CT rotational increment settings was calculated, and the optimal CT settings have been determined. Findings - The results have proven that reducing the rotational increment increases the sharpness of the captured images and the accuracy of crack length measurements. Nevertheless, the accuracy compared to high-resolution radiography measurements is only slightly better at 1/4° rotational increment than in the case of 1/2° rotational increment. It should be also noted that the 1/4° increment requires twice as much time for capturing the images as the 1/2° increment. So, the 1/2° rotational increment of sample projection is the optimal setting in our investigated case for measuring crack lengths. Practical implications - The developed method is applicable to find the optimal settings for CT crack length measurements, which provides faster analysation of large quantity samples used, e.g. at life-time tests. Originality/value - There is a lack of information in the literature regarding the optimisation of CT measurement set-up, e.g. a slightly larger value of the sample rotational increment can provide acceptable resolution with much faster processing time. Thus, the authors developed a method and performed research about optimising CT measurement parameters.",
keywords = "Computed tomography, Interfacial cracking, Pb-free, Thermal shock test, Vapour phase soldering, X-ray imaging",
author = "Tam{\'a}s Garami and Oliver Krammer and G. Hars{\'a}nyi and P{\'e}ter Martinek",
year = "2016",
month = "2",
day = "1",
doi = "10.1108/SSMT-10-2015-0029",
language = "English",
volume = "28",
pages = "13--17",
journal = "Soldering and Surface Mount Technology",
issn = "0954-0911",
publisher = "Emerald Group Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Method for validating CT length measurement of cracks inside solder joints

AU - Garami, Tamás

AU - Krammer, Oliver

AU - Harsányi, G.

AU - Martinek, Péter

PY - 2016/2/1

Y1 - 2016/2/1

N2 - Purpose - This paper aims to develop a method to measure the length of cracks inside solder joints, which enables the validation of computed tomography (CT) crack length measurements. Design/methodology/approach - Cracks were formed inside solder joints intentionally by aging solder joints of 0603 size resistors with thermal shock (TS) test (-40 to -140°C, 2,000 cycles), and CT images were captured about them with different rotational increment (1/4, 1/2 and 1°) of sample projection. The length of cracks was also measured with our method, which is based on capturing high-resolution radiography X-ray images about the cracks in two perpendicular projection planes. The radiography results were compared to the CT measurements. The percentage error for the different CT rotational increment settings was calculated, and the optimal CT settings have been determined. Findings - The results have proven that reducing the rotational increment increases the sharpness of the captured images and the accuracy of crack length measurements. Nevertheless, the accuracy compared to high-resolution radiography measurements is only slightly better at 1/4° rotational increment than in the case of 1/2° rotational increment. It should be also noted that the 1/4° increment requires twice as much time for capturing the images as the 1/2° increment. So, the 1/2° rotational increment of sample projection is the optimal setting in our investigated case for measuring crack lengths. Practical implications - The developed method is applicable to find the optimal settings for CT crack length measurements, which provides faster analysation of large quantity samples used, e.g. at life-time tests. Originality/value - There is a lack of information in the literature regarding the optimisation of CT measurement set-up, e.g. a slightly larger value of the sample rotational increment can provide acceptable resolution with much faster processing time. Thus, the authors developed a method and performed research about optimising CT measurement parameters.

AB - Purpose - This paper aims to develop a method to measure the length of cracks inside solder joints, which enables the validation of computed tomography (CT) crack length measurements. Design/methodology/approach - Cracks were formed inside solder joints intentionally by aging solder joints of 0603 size resistors with thermal shock (TS) test (-40 to -140°C, 2,000 cycles), and CT images were captured about them with different rotational increment (1/4, 1/2 and 1°) of sample projection. The length of cracks was also measured with our method, which is based on capturing high-resolution radiography X-ray images about the cracks in two perpendicular projection planes. The radiography results were compared to the CT measurements. The percentage error for the different CT rotational increment settings was calculated, and the optimal CT settings have been determined. Findings - The results have proven that reducing the rotational increment increases the sharpness of the captured images and the accuracy of crack length measurements. Nevertheless, the accuracy compared to high-resolution radiography measurements is only slightly better at 1/4° rotational increment than in the case of 1/2° rotational increment. It should be also noted that the 1/4° increment requires twice as much time for capturing the images as the 1/2° increment. So, the 1/2° rotational increment of sample projection is the optimal setting in our investigated case for measuring crack lengths. Practical implications - The developed method is applicable to find the optimal settings for CT crack length measurements, which provides faster analysation of large quantity samples used, e.g. at life-time tests. Originality/value - There is a lack of information in the literature regarding the optimisation of CT measurement set-up, e.g. a slightly larger value of the sample rotational increment can provide acceptable resolution with much faster processing time. Thus, the authors developed a method and performed research about optimising CT measurement parameters.

KW - Computed tomography

KW - Interfacial cracking

KW - Pb-free

KW - Thermal shock test

KW - Vapour phase soldering

KW - X-ray imaging

UR - http://www.scopus.com/inward/record.url?scp=84955453454&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84955453454&partnerID=8YFLogxK

U2 - 10.1108/SSMT-10-2015-0029

DO - 10.1108/SSMT-10-2015-0029

M3 - Article

AN - SCOPUS:84955453454

VL - 28

SP - 13

EP - 17

JO - Soldering and Surface Mount Technology

JF - Soldering and Surface Mount Technology

SN - 0954-0911

IS - 1

ER -