Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink.

Translated title of the contribution: Magnetic resonance cholangiography: our first experience

J. Mendly, G. Bajzik, K. Kéki, G. Rumi, I. Repa

Research output: Contribution to journalArticle

Abstract

Magnetic resonance cholangiography is a new field of clinical application within MR imaging, enabling high-quality imaging on disorders of the pancreaticobiliary system. This cross-sectional imaging technique is, by means of postprocessing, suitable for the production of reconstruction images appropriate for comparison with endoscopic retrograde cholangiography. The quality of the images thus obtained is dependent upon the level of development of the technology and software available. Observations arising from authors initial examinations using 2D fast spin echo sequence are summarised.

Original languageHungarian
Pages (from-to)3007-3011
Number of pages5
JournalOrvosi Hetilap
Volume139
Issue number50
Publication statusPublished - Dec 13 1998

Fingerprint

Cholangiography
Magnetic Resonance Spectroscopy
Computer-Assisted Image Processing
Software
Technology

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Mendly, J., Bajzik, G., Kéki, K., Rumi, G., & Repa, I. (1998). Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink. Orvosi Hetilap, 139(50), 3007-3011.

Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink. / Mendly, J.; Bajzik, G.; Kéki, K.; Rumi, G.; Repa, I.

In: Orvosi Hetilap, Vol. 139, No. 50, 13.12.1998, p. 3007-3011.

Research output: Contribution to journalArticle

Mendly, J, Bajzik, G, Kéki, K, Rumi, G & Repa, I 1998, 'Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink.', Orvosi Hetilap, vol. 139, no. 50, pp. 3007-3011.
Mendly J, Bajzik G, Kéki K, Rumi G, Repa I. Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink. Orvosi Hetilap. 1998 Dec 13;139(50):3007-3011.
Mendly, J. ; Bajzik, G. ; Kéki, K. ; Rumi, G. ; Repa, I. / Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink. In: Orvosi Hetilap. 1998 ; Vol. 139, No. 50. pp. 3007-3011.
@article{257d326c415c4ae2ad7f58c974c374f5,
title = "M{\'a}gneses rezonancia cholangiographi{\'a}val szerzett els{\'o} tapasztalataink.",
abstract = "Magnetic resonance cholangiography is a new field of clinical application within MR imaging, enabling high-quality imaging on disorders of the pancreaticobiliary system. This cross-sectional imaging technique is, by means of postprocessing, suitable for the production of reconstruction images appropriate for comparison with endoscopic retrograde cholangiography. The quality of the images thus obtained is dependent upon the level of development of the technology and software available. Observations arising from authors initial examinations using 2D fast spin echo sequence are summarised.",
author = "J. Mendly and G. Bajzik and K. K{\'e}ki and G. Rumi and I. Repa",
year = "1998",
month = "12",
day = "13",
language = "Hungarian",
volume = "139",
pages = "3007--3011",
journal = "Orvosi Hetilap",
issn = "0030-6002",
publisher = "Akademiai Kiado",
number = "50",

}

TY - JOUR

T1 - Mágneses rezonancia cholangiographiával szerzett elsó tapasztalataink.

AU - Mendly, J.

AU - Bajzik, G.

AU - Kéki, K.

AU - Rumi, G.

AU - Repa, I.

PY - 1998/12/13

Y1 - 1998/12/13

N2 - Magnetic resonance cholangiography is a new field of clinical application within MR imaging, enabling high-quality imaging on disorders of the pancreaticobiliary system. This cross-sectional imaging technique is, by means of postprocessing, suitable for the production of reconstruction images appropriate for comparison with endoscopic retrograde cholangiography. The quality of the images thus obtained is dependent upon the level of development of the technology and software available. Observations arising from authors initial examinations using 2D fast spin echo sequence are summarised.

AB - Magnetic resonance cholangiography is a new field of clinical application within MR imaging, enabling high-quality imaging on disorders of the pancreaticobiliary system. This cross-sectional imaging technique is, by means of postprocessing, suitable for the production of reconstruction images appropriate for comparison with endoscopic retrograde cholangiography. The quality of the images thus obtained is dependent upon the level of development of the technology and software available. Observations arising from authors initial examinations using 2D fast spin echo sequence are summarised.

UR - http://www.scopus.com/inward/record.url?scp=0032515233&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032515233&partnerID=8YFLogxK

M3 - Article

VL - 139

SP - 3007

EP - 3011

JO - Orvosi Hetilap

JF - Orvosi Hetilap

SN - 0030-6002

IS - 50

ER -