Az alacsonyszintü chemilumineszcencia mint az ischaemiás myocardialis károsodás kifejezöje.

Translated title of the contribution: Low-level chemoluminescence as a marker of ischemic myocardial damage

B. Török, T. Köszegi, K. Jobst

Research output: Contribution to journalReview article

1 Citation (Scopus)

Abstract

The low level chemiluminescence of intact and ischemic tissue homogenate of rat and dog heart have been investigated with luminometry. The t-butyl hydroperoxide-induced photoemission is increased in ischemic state and strict differences may be determined between the intact and ischemic samples. The light burst is intensiver in the infarct vs. intact region. On the other hand, the subendocardial layers show higher chemiluminescence.

Translated title of the contributionLow-level chemoluminescence as a marker of ischemic myocardial damage
Original languageHungarian
Pages (from-to)815-817
Number of pages3
JournalOrvosi hetilap
Volume132
Issue number15
Publication statusPublished - Apr 14 1991