For the direct separation of enantiomers of tryptophan analogs, a native α-cyclodextrin-based Cyclobond III chiral stationary phase was examined. The separation conditions were optimized by variation of the different chromatographic parameters, and data are reported as retention factors, separation factors and resolutions. The nature and concentration of the buffers as mobile phase additivies exerted only slight effects on the retention and resolution. In all cases, the erythro isomers could be separated significantly better than the threo ones. With increasing hydrophobicity of the analytes, the retention time increased, but no clear trend could be observed between the resolution and the hydrophobicity. The sequence of elution of the enantiomers was in most cases determined by spiking the racemic samples with enantiorich analytes.

Original languageEnglish
JournalChromatographia
Volume63
Issue numberSUPPL. 13
DOIs
Publication statusPublished - Jun 2006

Fingerprint

Cyclodextrins
Hydrophobic and Hydrophilic Interactions
Tryptophan
Enantiomers
Hydrophobicity
Buffers
Isomers

Keywords

  • α-Cyclodextrin- based column
  • β-Substituted Trp analogs
  • Column liquid chromatography
  • Direct enantioseparation

ASJC Scopus subject areas

  • Analytical Chemistry
  • Clinical Biochemistry

Cite this

LC enantioseparation of tryptophan analogs on α-cyclodextrin stationary phase. / Ilisz, I.; Sápi, J.; Tourwé, D.; Armstrong, D. W.; Péter, A.

In: Chromatographia, Vol. 63, No. SUPPL. 13, 06.2006.

Research output: Contribution to journalArticle

Ilisz, I. ; Sápi, J. ; Tourwé, D. ; Armstrong, D. W. ; Péter, A. / LC enantioseparation of tryptophan analogs on α-cyclodextrin stationary phase. In: Chromatographia. 2006 ; Vol. 63, No. SUPPL. 13.
@article{7de99b5c7e7d43d4a0818968f7a0249a,
title = "LC enantioseparation of tryptophan analogs on α-cyclodextrin stationary phase",
abstract = "For the direct separation of enantiomers of tryptophan analogs, a native α-cyclodextrin-based Cyclobond III chiral stationary phase was examined. The separation conditions were optimized by variation of the different chromatographic parameters, and data are reported as retention factors, separation factors and resolutions. The nature and concentration of the buffers as mobile phase additivies exerted only slight effects on the retention and resolution. In all cases, the erythro isomers could be separated significantly better than the threo ones. With increasing hydrophobicity of the analytes, the retention time increased, but no clear trend could be observed between the resolution and the hydrophobicity. The sequence of elution of the enantiomers was in most cases determined by spiking the racemic samples with enantiorich analytes.",
keywords = "α-Cyclodextrin- based column, β-Substituted Trp analogs, Column liquid chromatography, Direct enantioseparation",
author = "I. Ilisz and J. S{\'a}pi and D. Tourw{\'e} and Armstrong, {D. W.} and A. P{\'e}ter",
year = "2006",
month = "6",
doi = "10.1365/s10337-005-0699-0",
language = "English",
volume = "63",
journal = "Chromatographia",
issn = "0009-5893",
publisher = "Springer Vieweg",
number = "SUPPL. 13",

}

TY - JOUR

T1 - LC enantioseparation of tryptophan analogs on α-cyclodextrin stationary phase

AU - Ilisz, I.

AU - Sápi, J.

AU - Tourwé, D.

AU - Armstrong, D. W.

AU - Péter, A.

PY - 2006/6

Y1 - 2006/6

N2 - For the direct separation of enantiomers of tryptophan analogs, a native α-cyclodextrin-based Cyclobond III chiral stationary phase was examined. The separation conditions were optimized by variation of the different chromatographic parameters, and data are reported as retention factors, separation factors and resolutions. The nature and concentration of the buffers as mobile phase additivies exerted only slight effects on the retention and resolution. In all cases, the erythro isomers could be separated significantly better than the threo ones. With increasing hydrophobicity of the analytes, the retention time increased, but no clear trend could be observed between the resolution and the hydrophobicity. The sequence of elution of the enantiomers was in most cases determined by spiking the racemic samples with enantiorich analytes.

AB - For the direct separation of enantiomers of tryptophan analogs, a native α-cyclodextrin-based Cyclobond III chiral stationary phase was examined. The separation conditions were optimized by variation of the different chromatographic parameters, and data are reported as retention factors, separation factors and resolutions. The nature and concentration of the buffers as mobile phase additivies exerted only slight effects on the retention and resolution. In all cases, the erythro isomers could be separated significantly better than the threo ones. With increasing hydrophobicity of the analytes, the retention time increased, but no clear trend could be observed between the resolution and the hydrophobicity. The sequence of elution of the enantiomers was in most cases determined by spiking the racemic samples with enantiorich analytes.

KW - α-Cyclodextrin- based column

KW - β-Substituted Trp analogs

KW - Column liquid chromatography

KW - Direct enantioseparation

UR - http://www.scopus.com/inward/record.url?scp=33745169328&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745169328&partnerID=8YFLogxK

U2 - 10.1365/s10337-005-0699-0

DO - 10.1365/s10337-005-0699-0

M3 - Article

VL - 63

JO - Chromatographia

JF - Chromatographia

SN - 0009-5893

IS - SUPPL. 13

ER -