Investigation of size distribution and concentration of aerosols released at CODEX AIT experiments

P. Jani, A. Czitrovszky, A. Nagy, R. Hummel

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

During CODEX AIT experiments, measurements of aerosol release were performed on the facility constructed in AEKI. Two different optical counters were used in the experiments. The two counters registered simultaneously the occurrence of excursion. Measured values of cumulative particle concentrations exceeded 6.5 × 105 times those of the background values, while computed values of released mass exceeded more than six orders of magnitude their background values. Following a period of ten minutes in Ar gas, cooling the counters returned to their readings at the beginning of the experiment.

Original languageEnglish
JournalJournal of Aerosol Science
Volume30
Issue numberSuppl. 1
Publication statusPublished - Sep 1999

Fingerprint

Aerosols
aerosol
experiment
Experiments
Gases
Cooling
cooling
gas

ASJC Scopus subject areas

  • Atmospheric Science
  • Environmental Science(all)

Cite this

Investigation of size distribution and concentration of aerosols released at CODEX AIT experiments. / Jani, P.; Czitrovszky, A.; Nagy, A.; Hummel, R.

In: Journal of Aerosol Science, Vol. 30, No. Suppl. 1, 09.1999.

Research output: Contribution to journalArticle

@article{0f533ebc2ccc44bdbfc76e02469c6e54,
title = "Investigation of size distribution and concentration of aerosols released at CODEX AIT experiments",
abstract = "During CODEX AIT experiments, measurements of aerosol release were performed on the facility constructed in AEKI. Two different optical counters were used in the experiments. The two counters registered simultaneously the occurrence of excursion. Measured values of cumulative particle concentrations exceeded 6.5 × 105 times those of the background values, while computed values of released mass exceeded more than six orders of magnitude their background values. Following a period of ten minutes in Ar gas, cooling the counters returned to their readings at the beginning of the experiment.",
author = "P. Jani and A. Czitrovszky and A. Nagy and R. Hummel",
year = "1999",
month = "9",
language = "English",
volume = "30",
journal = "Journal of Aerosol Science",
issn = "0021-8502",
publisher = "Elsevier Limited",
number = "Suppl. 1",

}

TY - JOUR

T1 - Investigation of size distribution and concentration of aerosols released at CODEX AIT experiments

AU - Jani, P.

AU - Czitrovszky, A.

AU - Nagy, A.

AU - Hummel, R.

PY - 1999/9

Y1 - 1999/9

N2 - During CODEX AIT experiments, measurements of aerosol release were performed on the facility constructed in AEKI. Two different optical counters were used in the experiments. The two counters registered simultaneously the occurrence of excursion. Measured values of cumulative particle concentrations exceeded 6.5 × 105 times those of the background values, while computed values of released mass exceeded more than six orders of magnitude their background values. Following a period of ten minutes in Ar gas, cooling the counters returned to their readings at the beginning of the experiment.

AB - During CODEX AIT experiments, measurements of aerosol release were performed on the facility constructed in AEKI. Two different optical counters were used in the experiments. The two counters registered simultaneously the occurrence of excursion. Measured values of cumulative particle concentrations exceeded 6.5 × 105 times those of the background values, while computed values of released mass exceeded more than six orders of magnitude their background values. Following a period of ten minutes in Ar gas, cooling the counters returned to their readings at the beginning of the experiment.

UR - http://www.scopus.com/inward/record.url?scp=0033189851&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033189851&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0033189851

VL - 30

JO - Journal of Aerosol Science

JF - Journal of Aerosol Science

SN - 0021-8502

IS - Suppl. 1

ER -